본문 바로가기
KERD
논문KCI 등재

Comparison of shaping ability of the Reciproc Blue and One Curve with or without glide path in simulated S-shaped root canals

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: This study aimed to assess the impact of a glide-path on the shaping ability of 2 single-file instruments and to compare the centering ability, maintenance of original canal curvatures and area of instrumentation in simulated S-shaped root canals. Materials and methods: Forty simulated S-shaped root canals were used and were prepared with One Curve (group OC), One G and OC (group GOC), Reciproc Blue (group RB) and R-Pilot and RB (group PRB) and scanned before and after instrumentation. The images were analyzed using AutoCAD. After superimposing the samples, 4 levels (D1, D2, D3, and D4) and 2 angles (Δ1 and Δ2) were established to evaluate the centering ability and modification of the canal curvatures. Then, the area of instrumentation (ΔA) was measured. The data were analyzed using 2-way analysis of variance and Tukey's test for multiple comparisons (p < 0.05). Results: Regarding the centering ability in the apical part (D3, D4), the use of the glide-path yielded better results than the single-file groups. Among the groups at D4, OC showed the worst results (p < 0.05). The OC system removed less material (ΔA) than the RB system, and for Δ1, OC yielded a worse result than RB (p < 0.05). Conclusions: The glide-path improved the centering ability in the apical part of the simulated S-shaped canals. The RB system showed a better centering ability in the apical part and major respect of the canal curvatures compared with OC system.

Abstract

Objectives: This study aimed to assess the impact of a glide-path on the shaping ability of 2 single-file instruments and to compare the centering ability, maintenance of original canal curvatures and area of instrumentation in simulated S-shaped root canals. Materials and methods: Forty simulated S-shaped root canals were used and were prepared with One Curve (group OC), One G and OC (group GOC), Reciproc Blue (group RB) and R-Pilot and RB (group PRB) and scanned before and after instrumentation. The images were analyzed using AutoCAD. After superimposing the samples, 4 levels (D1, D2, D3, and D4) and 2 angles (Δ1 and Δ2) were established to evaluate the centering ability and modification of the canal curvatures. Then, the area of instrumentation (ΔA) was measured. The data were analyzed using 2-way analysis of variance and Tukey's test for multiple comparisons (p < 0.05). Results: Regarding the centering ability in the apical part (D3, D4), the use of the glide-path yielded better results than the single-file groups. Among the groups at D4, OC showed the worst results (p < 0.05). The OC system removed less material (ΔA) than the RB system, and for Δ1, OC yielded a worse result than RB (p < 0.05). Conclusions: The glide-path improved the centering ability in the apical part of the simulated S-shaped canals. The RB system showed a better centering ability in the apical part and major respect of the canal curvatures compared with OC system.

참고문헌 (39)

  1. Walia HM, "An initial investigation of the bending and torsional properties of Nitinol root canal files", J Endod, 14, pp.346~351 (1988)
  2. Bürklein S, "Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper", Int Endod J, 45, pp.449~461 (2012)
  3. Plotino G, "Cyclic fatigue of Reciproc and WaveOne reciprocating instruments", Int Endod J, 45, pp.614~618 (2012)
  4. De-Deus G, "The ability of the Reciproc R25 instrument to reach the full root canal working length without a glide path", Int Endod J, 46, pp.993~998 (2013)
  5. Zuolo ML, "Negotiability of second mesiobuccal canals in maxillary molars using a reciprocating system", J Endod, 41, pp.1913~1917 (2015)
  6. Yun HH, "A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 95, pp.228~233 (2003)
  7. Schäfer E, "Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 1. Shaping ability in simulated curved canals", Int Endod J, 36, pp.199~207 (2003)
  8. Peters OA, "Current challenges and concepts in the preparation of root canal systems: a review", J Endod, 30, pp.559~567 (2004)
  9. Greene KJ, "Clinical factors associated with ledged canals in maxillary and mandibular molars", Oral Surg Oral Med Oral Pathol, 70, pp.490~497 (1990)
  10. Schäfer E, "Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canals", Int Endod J, 37, pp.229~238 (2004)
  11. Plotino G, "Influence of negotiation, glide path, and preflaring procedures on root canal shaping-terminology, basic concepts, and a systematic review", J Endod, 46, pp.707~729 (2020)
  12. Ruddle CJ, "Endodontic canal preparation: innovations in glide path management and shaping canals", Dent Today, 33, pp.118~123 (2014)
  13. Berutti E, "Use of nickeltitanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals", J Endod, 35, pp.408~412 (2009)
  14. Pasqualini D, "Computed micro-tomographic evaluation of glide path with nickel-titanium rotary PathFile in maxillary first molars curved canals", J Endod, 38, pp.389~393 (2012)
  15. Plotino G, "Cyclic fatigue of reciproc and reciproc blue nickel-titanium reciprocating files at different environmental temperatures", J Endod, 44, pp.1549~1552 (2018)
  16. De-Deus G, "Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the reciproc files", J Endod, 43, pp.462~466 (2017)
  17. Özyürek T, "Comparison of cyclic fatigue resistance and bending properties of two reciprocating nickel-titanium glide path files", Int Endod J, 51, pp.1047~1052 (2018)
  18. Staffoli S, "Influence of environmental temperature, heat-treatment and design on the cyclic fatigue resistance of three generations of a single-file nickel-titanium rotary instrument", Odontology, 107, pp.301~307 (2019)
  19. Yılmaz K, "Cyclic fatigue resistances of several nickel-titanium glide path rotary and reciprocating instruments at body temperature", Int Endod J, 51, pp.924~930 (2018)
  20. Cunningham CJ, "A three-dimensional study of canal curvatures in the mesial roots of mandibular molars", J Endod, 18, pp.294~300 (1992)
  21. Berutti E, "Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments", J Endod, 30, pp.228~230 (2004)
  22. Patiño PV, "The influence of a manual glide path on the separation rate of NiTi rotary instruments", J Endod, 31, pp.114~116 (2005)
  23. D'Amario M, "Evaluation of a new nickeltitanium system to create the glide path in root canal preparation of curved canals", J Endod, 39, pp.1581~1584 (2013)
  24. Roland DD, "The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments", J Endod, 28, pp.543~545 (2002)
  25. Peters OA, "ProTaper rotary root canal preparation: effects of canal anatomy on final shape analysed by micro CT", Int Endod J, 36, pp.86~92 (2003)
  26. Abu Haimed A, "The root canal shaping ability of WaveOne and Reciproc versus ProTaper Universal and Mtwo rotary NiTi systems", Saudi Endod J, 7, pp.8~15 (2017)
  27. Yared G, "Canal preparation with only one reciprocating instrument without prior hand filing: a new concept", Quality Endodontic Distributors Ltd, 1~8 (2010)
  28. Uslu G, "Cyclic fatigue resistance of R-Pilot, HyFlex EDM and PathFile nickel-titanium glide path files in artificial canals with double (S-shaped) curvature", Int Endod J, 51, pp.584~589 (2018)
  29. Topçuoğlu HS, "Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature", Int Endod J, 50, pp.713~717 (2017)
  30. Hulsmann M, "Mechanical preparation of root canals: shaping goals, techniques and means", Endod Topics, 10, pp.30~76 (2005)
  31. Zhang L, "The shaping effect of the combination of two rotary nickel-titanium instruments in simulated S-shaped canals", J Endod, 34, pp.456~458 (2008)
  32. Keskin C, "Shaping ability of Reciproc Blue reciprocating instruments with or without glide path in simulated S-shaped root canals", J Dent Res Dent Clin Dent Prospect, 12, pp.63~67 (2018)
  33. Bürklein S, "Shaping ability of different nickel-titanium systems in simulated S-shaped canals with and without glide path", J Endod, 40, pp.1231~1234 (2014)
  34. Navós BV, "Centering and transportation: in vitro evaluation of continuous and reciprocating systems in curved root canals", J Conserv Dent, 19, pp.478~481 (2016)
  35. Jain A, "Comparative evaluation of canal transportation, centering ability, and remaining dentin thickness between WaveOne and ProTaper rotary by using cone beam computed tomography: an in vitro study", J Conserv Dent, 19, pp.440~444 (2016)
  36. Yao J, "Chemistry, physics and biology of graphene-based nanomaterials: New horizons for sensing, imaging and medicine", J Mater Chem, 22, pp.14313~14329 (2012)
  37. Elashiry MM, "Comparison of shaping ability of different single-file systems using microcomputed tomography", Eur J Dent, 14, pp.70~76 (2020)
  38. Özyürek T, "Shaping ability of reciproc, waveone gold, and hyflex edm single-file systems in simulated s-shaped canals", J Endod, 43, pp.805~809 (2017)
  39. Dhingra A, "Comparative evaluation of the canal curvature modifications after instrumentation with One Shape rotary and Wave One reciprocating files", J Conserv Dent, 17, pp.138~141 (2014)

관련 논문AI추천

이 간행물의 다른 논문 (13건)