Comparison of shaping ability of the Reciproc Blue and One Curve with or without glide path in simulated S-shaped root canals
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: This study aimed to assess the impact of a glide-path on the shaping ability of 2 single-file instruments and to compare the centering ability, maintenance of original canal curvatures and area of instrumentation in simulated S-shaped root canals. Materials and methods: Forty simulated S-shaped root canals were used and were prepared with One Curve (group OC), One G and OC (group GOC), Reciproc Blue (group RB) and R-Pilot and RB (group PRB) and scanned before and after instrumentation. The images were analyzed using AutoCAD. After superimposing the samples, 4 levels (D1, D2, D3, and D4) and 2 angles (Δ1 and Δ2) were established to evaluate the centering ability and modification of the canal curvatures. Then, the area of instrumentation (ΔA) was measured. The data were analyzed using 2-way analysis of variance and Tukey's test for multiple comparisons (p < 0.05). Results: Regarding the centering ability in the apical part (D3, D4), the use of the glide-path yielded better results than the single-file groups. Among the groups at D4, OC showed the worst results (p < 0.05). The OC system removed less material (ΔA) than the RB system, and for Δ1, OC yielded a worse result than RB (p < 0.05). Conclusions: The glide-path improved the centering ability in the apical part of the simulated S-shaped canals. The RB system showed a better centering ability in the apical part and major respect of the canal curvatures compared with OC system.
Abstract
Objectives: This study aimed to assess the impact of a glide-path on the shaping ability of 2 single-file instruments and to compare the centering ability, maintenance of original canal curvatures and area of instrumentation in simulated S-shaped root canals. Materials and methods: Forty simulated S-shaped root canals were used and were prepared with One Curve (group OC), One G and OC (group GOC), Reciproc Blue (group RB) and R-Pilot and RB (group PRB) and scanned before and after instrumentation. The images were analyzed using AutoCAD. After superimposing the samples, 4 levels (D1, D2, D3, and D4) and 2 angles (Δ1 and Δ2) were established to evaluate the centering ability and modification of the canal curvatures. Then, the area of instrumentation (ΔA) was measured. The data were analyzed using 2-way analysis of variance and Tukey's test for multiple comparisons (p < 0.05). Results: Regarding the centering ability in the apical part (D3, D4), the use of the glide-path yielded better results than the single-file groups. Among the groups at D4, OC showed the worst results (p < 0.05). The OC system removed less material (ΔA) than the RB system, and for Δ1, OC yielded a worse result than RB (p < 0.05). Conclusions: The glide-path improved the centering ability in the apical part of the simulated S-shaped canals. The RB system showed a better centering ability in the apical part and major respect of the canal curvatures compared with OC system.
참고문헌 (39)
- Walia HM, "An initial investigation of the bending and torsional properties of Nitinol root canal files", J Endod, 14, pp.346~351 (1988)
- Bürklein S, "Shaping ability and cleaning effectiveness of two single-file systems in severely curved root canals of extracted teeth: Reciproc and WaveOne versus Mtwo and ProTaper", Int Endod J, 45, pp.449~461 (2012)
- Plotino G, "Cyclic fatigue of Reciproc and WaveOne reciprocating instruments", Int Endod J, 45, pp.614~618 (2012)
- De-Deus G, "The ability of the Reciproc R25 instrument to reach the full root canal working length without a glide path", Int Endod J, 46, pp.993~998 (2013)
- Zuolo ML, "Negotiability of second mesiobuccal canals in maxillary molars using a reciprocating system", J Endod, 41, pp.1913~1917 (2015)
- Yun HH, "A comparison of the shaping abilities of 4 nickel-titanium rotary instruments in simulated root canals", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 95, pp.228~233 (2003)
- Schäfer E, "Efficiency of rotary nickel-titanium K3 instruments compared with stainless steel hand K-Flexofile. Part 1. Shaping ability in simulated curved canals", Int Endod J, 36, pp.199~207 (2003)
- Peters OA, "Current challenges and concepts in the preparation of root canal systems: a review", J Endod, 30, pp.559~567 (2004)
- Greene KJ, "Clinical factors associated with ledged canals in maxillary and mandibular molars", Oral Surg Oral Med Oral Pathol, 70, pp.490~497 (1990)
- Schäfer E, "Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canals", Int Endod J, 37, pp.229~238 (2004)
- Plotino G, "Influence of negotiation, glide path, and preflaring procedures on root canal shaping-terminology, basic concepts, and a systematic review", J Endod, 46, pp.707~729 (2020)
- Ruddle CJ, "Endodontic canal preparation: innovations in glide path management and shaping canals", Dent Today, 33, pp.118~123 (2014)
- Berutti E, "Use of nickeltitanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals", J Endod, 35, pp.408~412 (2009)
- Pasqualini D, "Computed micro-tomographic evaluation of glide path with nickel-titanium rotary PathFile in maxillary first molars curved canals", J Endod, 38, pp.389~393 (2012)
- Plotino G, "Cyclic fatigue of reciproc and reciproc blue nickel-titanium reciprocating files at different environmental temperatures", J Endod, 44, pp.1549~1552 (2018)
- De-Deus G, "Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the reciproc files", J Endod, 43, pp.462~466 (2017)
- Özyürek T, "Comparison of cyclic fatigue resistance and bending properties of two reciprocating nickel-titanium glide path files", Int Endod J, 51, pp.1047~1052 (2018)
- Staffoli S, "Influence of environmental temperature, heat-treatment and design on the cyclic fatigue resistance of three generations of a single-file nickel-titanium rotary instrument", Odontology, 107, pp.301~307 (2019)
- Yılmaz K, "Cyclic fatigue resistances of several nickel-titanium glide path rotary and reciprocating instruments at body temperature", Int Endod J, 51, pp.924~930 (2018)
- Cunningham CJ, "A three-dimensional study of canal curvatures in the mesial roots of mandibular molars", J Endod, 18, pp.294~300 (1992)
- Berutti E, "Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments", J Endod, 30, pp.228~230 (2004)
- Patiño PV, "The influence of a manual glide path on the separation rate of NiTi rotary instruments", J Endod, 31, pp.114~116 (2005)
- D'Amario M, "Evaluation of a new nickeltitanium system to create the glide path in root canal preparation of curved canals", J Endod, 39, pp.1581~1584 (2013)
- Roland DD, "The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments", J Endod, 28, pp.543~545 (2002)
- Peters OA, "ProTaper rotary root canal preparation: effects of canal anatomy on final shape analysed by micro CT", Int Endod J, 36, pp.86~92 (2003)
- Abu Haimed A, "The root canal shaping ability of WaveOne and Reciproc versus ProTaper Universal and Mtwo rotary NiTi systems", Saudi Endod J, 7, pp.8~15 (2017)
- Yared G, "Canal preparation with only one reciprocating instrument without prior hand filing: a new concept", Quality Endodontic Distributors Ltd, 1~8 (2010)
- Uslu G, "Cyclic fatigue resistance of R-Pilot, HyFlex EDM and PathFile nickel-titanium glide path files in artificial canals with double (S-shaped) curvature", Int Endod J, 51, pp.584~589 (2018)
- Topçuoğlu HS, "Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature", Int Endod J, 50, pp.713~717 (2017)
- Hulsmann M, "Mechanical preparation of root canals: shaping goals, techniques and means", Endod Topics, 10, pp.30~76 (2005)
- Zhang L, "The shaping effect of the combination of two rotary nickel-titanium instruments in simulated S-shaped canals", J Endod, 34, pp.456~458 (2008)
- Keskin C, "Shaping ability of Reciproc Blue reciprocating instruments with or without glide path in simulated S-shaped root canals", J Dent Res Dent Clin Dent Prospect, 12, pp.63~67 (2018)
- Bürklein S, "Shaping ability of different nickel-titanium systems in simulated S-shaped canals with and without glide path", J Endod, 40, pp.1231~1234 (2014)
- Navós BV, "Centering and transportation: in vitro evaluation of continuous and reciprocating systems in curved root canals", J Conserv Dent, 19, pp.478~481 (2016)
- Jain A, "Comparative evaluation of canal transportation, centering ability, and remaining dentin thickness between WaveOne and ProTaper rotary by using cone beam computed tomography: an in vitro study", J Conserv Dent, 19, pp.440~444 (2016)
- Yao J, "Chemistry, physics and biology of graphene-based nanomaterials: New horizons for sensing, imaging and medicine", J Mater Chem, 22, pp.14313~14329 (2012)
- Elashiry MM, "Comparison of shaping ability of different single-file systems using microcomputed tomography", Eur J Dent, 14, pp.70~76 (2020)
- Özyürek T, "Shaping ability of reciproc, waveone gold, and hyflex edm single-file systems in simulated s-shaped canals", J Endod, 43, pp.805~809 (2017)
- Dhingra A, "Comparative evaluation of the canal curvature modifications after instrumentation with One Shape rotary and Wave One reciprocating files", J Conserv Dent, 17, pp.138~141 (2014)
