Objectives: This in vitro study aimed to evaluate temperature variation on the external surface of mandibular molars and within ultrasonic inserts when using adapter-coupled versus one-piece inserts.Methods: Twenty-four extracted human mandibular molars were divided into two groups based on the type of ultrasonic insert used: adapter-coupled and one-piece inserts. Temperature on the external surface of each tooth was measured with a thermocouple probe positioned in the furcation area, capturing data continuously. The temperature of the ultrasonic inserts was monitored in real-time using a thermal imaging camera. Measurements were taken in a controlled environment without cooling for over 120 seconds. Statistical analysis was conducted using analysis of variance (ANOVA) and two-way ANOVA with repeated measures to evaluate temperature variations between groups and over time, with significance set at 5%.Results: In the external tooth surface temperature measurements, no significant differences were observed between the groups during the initial 15 seconds (p = 0.185) and 30 seconds (p = 0.067). However, significant differences emerged at 60 seconds (p = 0.025), 90 seconds (p = 0.024), and 120 seconds (p = 0.020), with the one-piece insert group demonstrating higher temperatures in the furcation region. Thermal imaging of the inserts revealed a significant difference at all time points (p < 0.001), with adapter-coupled inserts showing greater heating.Conclusions: The use of ultrasonic inserts leads to a gradual rise in temperature on the external tooth surface. One-piece inserts generated higher temperatures on the tooth, while adapter-coupled inserts exhibited greater heating within the insert.

Abstract

Objectives: This in vitro study aimed to evaluate temperature variation on the external surface of mandibular molars and within ultrasonic inserts when using adapter-coupled versus one-piece inserts.Methods: Twenty-four extracted human mandibular molars were divided into two groups based on the type of ultrasonic insert used: adapter-coupled and one-piece inserts. Temperature on the external surface of each tooth was measured with a thermocouple probe positioned in the furcation area, capturing data continuously. The temperature of the ultrasonic inserts was monitored in real-time using a thermal imaging camera. Measurements were taken in a controlled environment without cooling for over 120 seconds. Statistical analysis was conducted using analysis of variance (ANOVA) and two-way ANOVA with repeated measures to evaluate temperature variations between groups and over time, with significance set at 5%.Results: In the external tooth surface temperature measurements, no significant differences were observed between the groups during the initial 15 seconds (p = 0.185) and 30 seconds (p = 0.067). However, significant differences emerged at 60 seconds (p = 0.025), 90 seconds (p = 0.024), and 120 seconds (p = 0.020), with the one-piece insert group demonstrating higher temperatures in the furcation region. Thermal imaging of the inserts revealed a significant difference at all time points (p < 0.001), with adapter-coupled inserts showing greater heating.Conclusions: The use of ultrasonic inserts leads to a gradual rise in temperature on the external tooth surface. One-piece inserts generated higher temperatures on the tooth, while adapter-coupled inserts exhibited greater heating within the insert.

관련 논문AI추천

A comparison of magnetostrictive and piezoelectric ultrasonic scaling devices: an in vitro studyHojatollah Yousefimanesh, Mahdi Kadkhodazadeh, Maryam Robati, Reza Molla대한치주과학회 · Journal of Periodontal & Implant Science2012 · 제42권 제6호Effect of a metallic ultrasonic scaler tip on titanium surfaces: a preliminary studyByung-Ock Kim, Hyun-Min Lee, Min-Cheol Yang, Sang-Joun Yu, Seok-Hwan Jeong, Seung-Hwan Seol, Seung-Kyu Lee치의학연구원 · Oral Biology Research2024 · 제48권 제2호Effect of cooling water temperature on the temperature changes in pulp chamber and at handpiece head during high-speed tooth preparationRa'fat I. Farah대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제1호Evaluation of Pain Reduction and Clinical Efficacy of Feedback-Controlled Ultrasonic Scaler정임희, 황영선, Hee-jung Lim, Min-ju Kim, Myoung-hee Kim한국치위생과학회 · 치위생과학회지2023 · 제23권 제2호Comparison of the effect of hand instruments, an ultrasonic scaler, and an erbium-doped yttrium aluminium garnet laser on root surface roughness of teeth with periodontitis: a profilometer studyArash Ghafoori, Farzin Hajizadeh, Mahdi Kadkhodazadeh, Reza Amid, Reza Fekrazad대한치주과학회 · Journal of Periodontal & Implant Science2013 · 제43권 제2호Effect of ultrasonic tip designs on intraradicular post removalAndré Augusto Franco Marques, Angela Delfina Bitencourt Garrido, Anny Carine Barros Aguiar, Daniely Amorim de Meireles, Emílio Carlos Sponchiado Júnior, Lucas da Fonseca Roberti Garcia대한치과보존학회 · Restorative Dentistry and Endodontics2014 · 제39권 제4호

이 간행물의 다른 논문 (9건)