본문 바로가기
KERD
논문KCI 등재

기능적 부하 후 임플란트 주변의 골 흡수에 대한 방사선학적 연구

STUDY ON RADIOGRAPHIC EVALUATION OF MARGINAL BONE LOSS AROUND OSSEOINTEGRATED IMPLANT AFTER FUNCTIONAL LOADING

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: The purpose of this study was to evaluate marginal bone loss to the bone crest functionally loaded for up to eighteen months and also with regard to other variables of interest. Material and Methods: 135 endosseous implants(GS Ⅱ, Osstem, South Korea) were placed in 35 patients. The design of GS II implant is straight with the microthread. Radiographic examinations were conducted at baseline (implant loading) and 3, 6, 9, 12 and 18 months after loading. Marginal bone level measurement was made from the reference point to the lowest observed point of contact of the marginal bone with the fixture. The reference point of the fixture was the border between the blasted surface and machined surface of the fixture. Results: Implants were on function for a mean 12.7 months(range, 3?18 months). For the 56 maxillary and 79 mandibular implants, mean marginal bone loss was 0.68 mm and 0.70 mm. Implants placed maxillary posterior area displayed more crestal bone loss than the other position. The difference between mesial and distal bone levels was statistically significant (p<0.05) with respective means of 0.51 mm and 0.62 mm. Also, The difference between bone graft group and no-bone graft group was statistically significant(p<0.05) with respective means of 0.38 mm and 0.66 mm. But no statistically significant influence of sex, type of surgery(one or two stage surgery), the implant length was observed(p>0.05). Conclusion: This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

Abstract

Purpose: The purpose of this study was to evaluate marginal bone loss to the bone crest functionally loaded for up to eighteen months and also with regard to other variables of interest. Material and Methods: 135 endosseous implants(GS Ⅱ, Osstem, South Korea) were placed in 35 patients. The design of GS II implant is straight with the microthread. Radiographic examinations were conducted at baseline (implant loading) and 3, 6, 9, 12 and 18 months after loading. Marginal bone level measurement was made from the reference point to the lowest observed point of contact of the marginal bone with the fixture. The reference point of the fixture was the border between the blasted surface and machined surface of the fixture. Results: Implants were on function for a mean 12.7 months(range, 3?18 months). For the 56 maxillary and 79 mandibular implants, mean marginal bone loss was 0.68 mm and 0.70 mm. Implants placed maxillary posterior area displayed more crestal bone loss than the other position. The difference between mesial and distal bone levels was statistically significant (p<0.05) with respective means of 0.51 mm and 0.62 mm. Also, The difference between bone graft group and no-bone graft group was statistically significant(p<0.05) with respective means of 0.38 mm and 0.66 mm. But no statistically significant influence of sex, type of surgery(one or two stage surgery), the implant length was observed(p>0.05). Conclusion: This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

참고문헌 (36)

  1. Albrektsson T, "The longterm efficacy of currently used dental implants: A review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
  2. Adell R, "Marginal tissue reactions at osseointegrated titanium fixtures. A 3-year longitudinal prospective study", Int J Oral Maxillofac Implants, 15, pp.39~52 (1986)
  3. Jemt T, "3-Year follow-up study of early single implant restoration ad modum Branemark", Int J Periodontics Restorative Dent, 10, pp.341~349 (1990)
  4. Jung YC, "A 1 year radiographic evaluation of margingla bone around dental implants", Int J Oral Maxillofac Implants, 11, pp.811~818 (1996)
  5. Misch CE, "A scientific rationale for dental implant design, in Contemporary Implant Dentistry", pp.329~343 (1999), Mosby
  6. Quirynen M, "Periodontal aspects of osseointegrated fixtures supporting a partial bridges. An up to 6-years retrospective study", Journal of Clinical Periodontology, 19, pp.118~126 (1992)
  7. Michael R, Norton, "Marginal bone levels at single tooth implants with a conical fixture design, The influence of surface macro-and microstructure", Clin Oral Impl Res, 9, pp.91~99 (1998)
  8. Engquist B, "Marginal bone reaction to oral implants: a prospective comparative study of Astra Tech and Branemark System implants", Clin Oral Implants Res, 13, pp.30~37 (2002)
  9. 신동환, "임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구", The Journal of the Korean Academy of Periodontology (JPIS), 33(3), pp.349~358 (2003), 대한치주과학회
  10. Gotfredsen K, "Marginal tissue response adjacent to Astra Dental Implants supporting overdentures in the mandible. A 2-year follow-up study", Clin Oral Implants Res, 4, pp.83~89 (1993)
  11. Hollender L, "Radiographic evaluation of osseointegrated implants in the jaws", Journal of Dentomaxillofacial Radiology, 9, pp.91~95 (1980)
  12. Cox JF, "An alternative holder for radiographic evaluation of tissue integrated prosthese", J of Prosthetic Dentistry, 56, pp.338~341 (1985)
  13. Molander B, "Agreement between panoramic and intraoral radiography in the assessment of marginal bone height", Journal of Dentomaxillofacial Radiology, 20, pp.155~160 (1991)
  14. Oh TJ, "The caused of early implant bone loss:myth or science?", J Periodontol, 73, pp.322~333 (2002)
  15. Jeong SM, "Bone healing around implants following flap and mini-flap surgeries: A radiographic evaluation between stage I and stage II surgery", Oral Surg Oral Med Oral Pathol Oral Radiol Endol, 105, pp.293~296 (2008)
  16. Eriksson RA, "The effect of heat on bone regeneration", J Oral Maxillofac surg, 42, pp.701~711 (1984)
  17. Hermann JS, "Crestal bone changed around titanium implants. A radiographic evaluaion of unloaded nonsubmerged and submerged implants in the canine mandible", J Periodontol, 68, pp.1117~1130 (1997)
  18. Ericsson I, "Different types of inflammatory reactions in peri-implant soft tissues", J Clin Periodontol, 22, pp.255~261 (1995)
  19. Berglundh T, "The soft tissue barrier at implants and teeth", Clin Oral Implants Res, 2, pp.81~90 (1991)
  20. Siegele D, "Numerical investigations of influence of implant shape on stress distribution in the jaw bone", Int J Oral Maxillofac Implant, 4, pp.333~ (1989)
  21. Guo EX, "Mechanical properties of cortical bone and cancellous bone tissue, in Bone Mechanics Handbook", pp.1~23 (2001), CRC Press
  22. Hansson S, "The implant neck: smooth or provided with retention elements. A biomechanical approach", Clin Oral Implants Res, 10, pp.394~405 (1999)
  23. North MR, "Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macro- and microstructure", Clin Oral Implants Res, 9, pp.91~99 (1998)
  24. Palmer RM, "A prospective study of Astra single tooth implants", Clin Oral Implants Res, 8, pp.173~179 (1997)
  25. Lee DW, "Effect of microthread on the maintenance of marginal bone level: a 3-year prospective study", Clin Oral Implants Res, 18, pp.465~470 (2007)
  26. Abrahammson I, "Tissue Characteristics at Microthreaded Implants: An Experimental Study in Dogs", Clin Oral Implants Res, 8, pp.107~113 (2006)
  27. Wyatt CCL, "Treatment outcomes of patients with implant- supported fixed partial prostheses", Int J Oral Maxillofac Implants, 13, pp.204~211 (1998)
  28. Peñarrocha M, "Radiologic study of marginal bone loss around 108 dental implants and its relationship to smoking, implant location and morphology", Int J Oral Maxillofac Implants, 19, pp.861~867 (2004)
  29. Tada S, "Influence of implant design and bone quality on stress", strain distribution in bone around implants: a 3-dimensional finite element analysis, 2003, pp.18, 357~368
  30. Petrie CS, "Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis", Clin Oral Implants Res, 16, pp.486~494 (2005)
  31. Hertel R, "Influence of the dimensions of implant superstructure on peri-implant bone loss", Int J Prosthodont, 6, pp.18~ (1993)
  32. Jovanovic SA, "Bone regeneration around titanium dental implants in dehisced defect sites. A clinical study", Int J Oral Maxillofac Implants, 7, pp.233~245 (1992)
  33. Zitzmann NU, "Long-term results of implants treated with guided bone regeneration: A 5-year prospective study", Int J Oral Maxillofac Implnats, 16, pp.355~366 (2001)
  34. Jensen OT, "Vertical guided bone graft augmentation in an new canine mandibular model", Int J Oral Maxillofac Implants, 10, pp.335~344 (1995)
  35. Christoph HF, "A systematic review of the survival of implants in bone sites augmented with barrier membranes(guided bone regeneration) in partially edentulous patients", J Clin Periodontology, 29(3), pp.226~231 (2002)
  36. Hardt CRE, "Outcome of implant therapy in relation to experienced loss of periodontal bone support. A retrospective 5-year study", Clin Oral Implants Res, 13, pp.488~494 (2002)

관련 논문AI추천

이 간행물의 다른 논문 (12건)