본문 바로가기
KERD
논문KCI 등재

A comparison of fixation methods using three-dimensional finite element analysis following anterior segmental osteotomy

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: This study sought to evaluate fixation methods and determine the best method for the postoperative stabilization of maxillary osteotomy. For our analysis we performed a three-dimensional finite element analysis of stress distribution on the plate, screw, and surrounding bone, as well as displacement onto the plate. Materials and Methods: We generated a model using synthetic skull scan data; an initital surface model was changed to a solid model using software. Modified anterior segmental osteotomy (using Park’s method) was made using the program, and four different types of fixation methods were used. An anterior load of 100 N was applied on the palatal surface of two central incisors. Results: The Type 1 (L-shaped) fixation method gave stresses of 187.8 MPa at the plate, 45.8 MPa at the screw, and 15.4 MPa at the bone around the plate. The Type 2 (I-shaped) fixation method gave stresses of 186.6 MPa at the plate, 75.7 MPa at the screw, and 13.8 MPa at the bone around the plate. The Type 3 (inverted L-shaped) fixation method gave stresses of 28.6 MPa at the plate, 29.9 MPa at the screw, and 15.3 MPa at the bone around the plate. The Type 4 (I-shaped) fixation method gave stresses of 34.8 MPa at the plate, 36.9 MPa at the screw, and 14.9 MPa at the bone around the plate. The deflection of the plates for the four fixation methods was 0.014 mm, 0.022 mm, 0.017 mm, and 0.018 mm, respectively. Conclusion: The Type 3 (inverted L-shaped) fixation method offers more stability than the other fixation methods. We therefore recommend this method for the postoperative stabilization of maxillary osteotomy.

Abstract

Objectives: This study sought to evaluate fixation methods and determine the best method for the postoperative stabilization of maxillary osteotomy. For our analysis we performed a three-dimensional finite element analysis of stress distribution on the plate, screw, and surrounding bone, as well as displacement onto the plate. Materials and Methods: We generated a model using synthetic skull scan data; an initital surface model was changed to a solid model using software. Modified anterior segmental osteotomy (using Park’s method) was made using the program, and four different types of fixation methods were used. An anterior load of 100 N was applied on the palatal surface of two central incisors. Results: The Type 1 (L-shaped) fixation method gave stresses of 187.8 MPa at the plate, 45.8 MPa at the screw, and 15.4 MPa at the bone around the plate. The Type 2 (I-shaped) fixation method gave stresses of 186.6 MPa at the plate, 75.7 MPa at the screw, and 13.8 MPa at the bone around the plate. The Type 3 (inverted L-shaped) fixation method gave stresses of 28.6 MPa at the plate, 29.9 MPa at the screw, and 15.3 MPa at the bone around the plate. The Type 4 (I-shaped) fixation method gave stresses of 34.8 MPa at the plate, 36.9 MPa at the screw, and 14.9 MPa at the bone around the plate. The deflection of the plates for the four fixation methods was 0.014 mm, 0.022 mm, 0.017 mm, and 0.018 mm, respectively. Conclusion: The Type 3 (inverted L-shaped) fixation method offers more stability than the other fixation methods. We therefore recommend this method for the postoperative stabilization of maxillary osteotomy.

참고문헌 (21)

  1. Bell WH, "Surgical correction of dentofacial deformities", pp.1015~ (1980), Saunders
  2. Chu YM, "Surgical approach to the patient with bimaxillary protrusion", Clin Plast Surg, 34, pp.535~546 (2007)
  3. Baek SH, "Determinants of successful treatment of bimaxillary protrusion: orthodontic treatment versus anterior segmental osteotomy.", J Craniofac Surg, 16, pp.234~246 (2005)
  4. Jacobs JD, "Combined surgical and orthodontic treatment of bimaxillary protrusion", Am J Orthod, 83, pp.321~333 (1983)
  5. Rosenquist B, "Anterior segmental maxillary osteotomy. A 24-month follow-up", Int J Oral Maxillofac Surg, 22, pp.210~213 (1993)
  6. Park JU, "Orthognathic surgery", pp.267~ (2003), Koonja Publishing
  7. 이혜련, "Evaluation of the soft and hard tissue changes after anterior segmental osteotomy on the maxifla and mandible", JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 66, pp.98~103, CHURCHILL LIVINGSTONE, JOURNAL PRODUCTION DEPT,
  8. Atac MS, "Comparison of biomechanical behaviour of maxilla following Le Fort I osteotomy with 2- versus 4-plate fixation using 3D-FEA. Part 1: advancement surgery", Int J Oral Maxillofac Surg, 37, pp.1117~1124 (2008)
  9. Poiate IA, "Three dimensional finite element analyses of oral structures by computerized tomography", J Biosci Bioeng, 106, pp.606~609 (2008)
  10. Tanne K, "Three-dimensional model of the human craniofacial skeleton: method and preliminary results using finite element analysis", J Biomed Eng, 10, pp.246~252 (1988)
  11. Tanne K, "Three-dimensional finite element analysis for stress in the periodontal tissue by orthodontic forces", Am J Orthod Dentofacial Orthop, 92, pp.499~505 (1987)
  12. Proffit WR, "Combined surgical and orthodontic treatment, In Contemporary orthodontics", pp.686~ (2007), Elsevier Inc
  13. Ziccardi VB, "Anterior and posterior maxillary segmental osteotomies, In Oral and maxillofacial surgery", pp.249~ (2000), Saunders
  14. Korkmaz HH, "Evaluation of different miniplates in fixation of fractured human mandible with the finite element method", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 103, pp.1~13 (2007)
  15. Gunaseelan R, "Intraoperative and perioperative complications in anterior maxillary osteotomy: a retrospective evaluation of 103 patients", J Oral Maxillofac Surg, 67, pp.1269~1273 (2009)
  16. Vollmer D, "Experimental and finite element study of a human mandible", J Craniomaxillofac Surg, 28, pp.91~96 (2000)
  17. Atac MS, "Comparison of biomechanical behaviour of maxilla following Le Fort I osteotomy with 2- versus 4-plate fixation using 3D-FEA Part 2: impaction surgery", Int J Oral Maxillofac Surg, 38, pp.58~63 (2009)
  18. Erkmen E, "Comparison of biomechanical behaviour of maxilla following Le Fort I osteotomy with 2- versus 4-plate fixation using 3D-FEA: part 3: inferior and anterior repositioning surgery", Int J Oral Maxillofac Surg, 38, pp.173~179 (2009)
  19. Alberts LR, "A biologic model for assessment of osseous strain patterns and plating systems in the human maxilla", J Oral Maxillofac Surg, 61, pp.79~88 (2003)
  20. Armstrong JE, "Preliminary investigation of the biomechanics of internal fixation of sagittal split osteotomies with miniplates using a newly designed in vitro testing model", J Oral Maxillofac Surg, 59, pp.191~195 (2001)
  21. Song HC, "Functional and morphologic alterations after anterior or inferior repositioning of the maxilla", J Oral Maxillofac Surg, 55, pp.41~49 (1997)

관련 논문AI추천

Three-dimensional finite element analysis of the stress distribution and displacement in different fixation methods of bilateral sagittal split ramus osteotomy박재억, 윤경인, Jong Min Lee, Myung-Kyun Park, Yoon-Hee Park, Young-Gyu Cho대한구강악안면외과학회 · 대한구강악안면외과학회지2012 · 제38권 제5호Three-dimensional finite element analysis on the effects of maxillary protraction with an individual titanium plate at multiple directions and locationsFan Wang, Qiao Chang, Shuran Liang, Yuxing Bai대한치과교정학회 · 대한치과교정학회지2024 · 제54권 제2호Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomyDouglas Rangel Goulart, Eder Alberto Sigua-Rodriguez, José Ricardo Albergaria-Barbosa, Leandro Pozzer, Sergio Olate, Zarina Tatia Barbosa Vieira Santos대한구강악안면외과학회 · 대한구강악안면외과학회지2017 · 제43권 제2호An in vitro comparison between two different designs of sagittal split ramus osteotomyFabio Loureiro Sato, Jose Ricardo Albergaria-Barbosa, Leandro Pozzer, Leonardo Flores Luthi, Sergio Olate, Valdir Cabral Andrade대한구강악안면외과학회 · 대한구강악안면외과학회지2015 · 제41권 제3호Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length김성훈, 정규림, Bohm Choi, Dong-Ok Lee, Gerald Nelson, Ki-Ho Park, Seong Ho Han, Sung-Seo Mo대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제6호하악 이부확장 시 하악골 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구김상철, 이도훈, 조진형, 채종문, 홍현실대한치과교정학회 · 대한치과교정학회지2008 · 제38권 제1호

이 간행물의 다른 논문 (11건)