Direction of the J-Tip of the Guidewire to Decrease the Malposition Rate of an Internal Jugular Vein Catheter
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Background: We hypothesized that the direction of the J-tip of the guidewire during insertion into the internal jugular vein (IJV) might determine its ultimate location. Methods: In this study, 300 patients between the ages of 18 and 99 years who required central venous catheterization via IJV in the emergency department enrolled for randomization. IVJ catheterization was successful in 285 of 300 patients. An independent operator randomly prefixed the direction of the J-tip of the guidewire to one of three directions. Based on the direction of the J-tip, patients were allocated into three groups: the J-tip medial-directed group (Group A), the lateral-directed group (Group B), or the downwarddirected group (Group C). Postoperative chest radiography was performed on all patients in order to visualize the location of the catheter tip. A catheter is considered malpositioned if it is not located in the superior vena cava or right atrium. Results: Of the total malpositioned catheter tips (8 of 285; 2.8%), the majority (5 of 8; 62.5%) entered the contralateral subclavian vein, 2 (25.0%) were complicated by looping, and 1 (12.5%) entered the ipsilateral subclavian vein. According to the direction of the Jtip of the guidewire, the incidence of malpositioning of the catheter tip was 4 of 92 in Group A (4.3%), 4 of 96 in Group B (4.2%), and there were no malpositions in Group C. There were no significant differences among the three groups (p = 0.114). Conclusions: The direction of the J-tip of the guidewire had no statistically significant effect on incidence of malpositioned tips.
Abstract
Background: We hypothesized that the direction of the J-tip of the guidewire during insertion into the internal jugular vein (IJV) might determine its ultimate location. Methods: In this study, 300 patients between the ages of 18 and 99 years who required central venous catheterization via IJV in the emergency department enrolled for randomization. IVJ catheterization was successful in 285 of 300 patients. An independent operator randomly prefixed the direction of the J-tip of the guidewire to one of three directions. Based on the direction of the J-tip, patients were allocated into three groups: the J-tip medial-directed group (Group A), the lateral-directed group (Group B), or the downwarddirected group (Group C). Postoperative chest radiography was performed on all patients in order to visualize the location of the catheter tip. A catheter is considered malpositioned if it is not located in the superior vena cava or right atrium. Results: Of the total malpositioned catheter tips (8 of 285; 2.8%), the majority (5 of 8; 62.5%) entered the contralateral subclavian vein, 2 (25.0%) were complicated by looping, and 1 (12.5%) entered the ipsilateral subclavian vein. According to the direction of the Jtip of the guidewire, the incidence of malpositioning of the catheter tip was 4 of 92 in Group A (4.3%), 4 of 96 in Group B (4.2%), and there were no malpositions in Group C. There were no significant differences among the three groups (p = 0.114). Conclusions: The direction of the J-tip of the guidewire had no statistically significant effect on incidence of malpositioned tips.
참고문헌 (17)
- Miller AH, "Ultrasound guidance versus landmark technique for the placement of central venous catheters in the emergency department", Acad Emeg Med, 9, pp.800~805 (2002)
- Ruesch S, "Complications of central venous catheters: internal jugular versus subclavian access--a systematic review", Crit Care Med, 30, pp.454~460 (2002)
- Boardman P, "Radiological evaluation and management of malfunctioning central venous catheters", Clin Radiol, 53, pp.10~16 (1998)
- Oh AY, "The influence of the direction of J-tip on placement of a subclavian catheter: real time ultrasound-guided cannulation versus landmark method, a randomized controlled trial", BMC Anesthesiology, 14, pp.11~ (2014)
- Sanchez R, "Misplacement of subclavian venous catheters: importance of head position and choice of puncture site", Br J Anaesth, 64, pp.632~633 (1990)
- Kang M, "Influence of shoulder position on central venous catheter tip location during infraclavicular subclavian approach", Br J Anaesth, 106, pp.344~347 (2011)
- Tripathi M, "Direction of the Jtip of the guidewire, in seldinger technique, is a significant factor in misplacement of subclavian vein catheter:a randomized, controlled study", Anesth Analg, 100, pp.21~24 (2005)
- 안홍준, "중심정맥도관삽입술 시 위치이상의 빈도를 감소시키는 방법: 실시간 초음파 유도하 재위치", 대한중환자의학회지, 28(4), pp.280~286 (2013), 대한중환자의학회
- Leung J, "Real-time ultrasonographically-guided internal jugular vein catheterization in the emergency department increases success rates and reduces complications: a randomized, prospective study", Ann Emerg Med, 48, pp.540~547 (2006)
- Felleiter P, "Use of electrocardiographic placement control of central venous catheters in Austria", Acta Med Austriaca, 26, pp.109~113 (1999)
- Wang HE, "Subclavian central venous catheterization complicated by guidewire looping and entrapment", J Emerg Med, 17, pp.721~724 (1999)
- Maffessanti M, "Malpositions and complications following central venous catheterization in relation to the access site", Radiol Med, 75, pp.609~612 (1988)
- Muhm M, "Malposition of central venous catheters. Incidence, management and preventive practices", Wien Klin Wochenschr, 109, pp.400~405 (1997)
- Bagwell CE, "Potentially lethal complications of central venous catheter placement", J Pediatr Surg, 35, pp.709~713 (2000)
- McGee WT, "Accurate placement of central venous catheters: a prospective, randomized, multicenter trial", Crit Care Med, 21, pp.1118~1123 (1993)
- Peres PW, "Positioning central venous catheters--a prospective survey", Anaesth Intensive Care, 18, pp.536~539 (1990)
- Vesely TM, "Central venous catheter tip position: a continuing controversy", J Vasc Interv Radiol, 14, pp.527~534 (2003)