Despite the overall satisfactory results of total hip arthroplasty, post-operative complications continue to occur. To minimize these problems, computer-assisted total hip arthroplasty using navigation or robot-assisted systems is being developed. A navigation system is defined as a system that locates a position in three-dimensional space and traces the target spot, and a robot-assisted system is defined as a system that performs operations automatically with mechanical robot arms based on prior preoperative planning. Computer-assisted surgeries have shown superior results to conventional methods in implant positioning, fixation, and accurate lower extremity alignment in the limited reports available. However, computer-assisted surgeries take longer compared to conventional methods. Due to the extra time needed, the risk of postoperative infection and blood loss is considered to be higher. Nevertheless, robot-assisted system is being developed for the field of hip arthroplasty, and thus its efficacy and accuracy needs to be further investigated. Since these methods have other advantages compared to conventional methods, they are the focus of much interest.

Abstract

Despite the overall satisfactory results of total hip arthroplasty, post-operative complications continue to occur. To minimize these problems, computer-assisted total hip arthroplasty using navigation or robot-assisted systems is being developed. A navigation system is defined as a system that locates a position in three-dimensional space and traces the target spot, and a robot-assisted system is defined as a system that performs operations automatically with mechanical robot arms based on prior preoperative planning. Computer-assisted surgeries have shown superior results to conventional methods in implant positioning, fixation, and accurate lower extremity alignment in the limited reports available. However, computer-assisted surgeries take longer compared to conventional methods. Due to the extra time needed, the risk of postoperative infection and blood loss is considered to be higher. Nevertheless, robot-assisted system is being developed for the field of hip arthroplasty, and thus its efficacy and accuracy needs to be further investigated. Since these methods have other advantages compared to conventional methods, they are the focus of much interest.

참고문헌 (25)

  1. Parvizi J, "Recurrent instability after total hip arthroplasty: beware of subtle component malpositioning", Clin Orthop Relat Res, 447, pp.60~65 (2006)
  2. Bonutti PM, "Minimally invasive total knee arthroplasty using the contralateral knee as a control group: a case-control study", Int Orthop, 34, pp.491~495 (2010)
  3. Bargar WL, "Primary and revision total hip replacement using the Robodoc system", Clin Orthop Relat Res, 354, pp.82~91 (1998)
  4. Paul HA, "Development of a surgical robot for cementless total hip arthroplasty", Clin Orthop Relat Res, 285, pp.57~66 (1992)
  5. Stulberg SD, "Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients", J Bone Joint Surg Am, 84(2), pp.90~98 (2002)
  6. Dalury DF, "Mini-incision total knee arthroplasty can increase risk of component malalignment", Clin Orthop Relat Res, 440, pp.77~81 (2005)
  7. Saxler G, "The accuracy of free-hand cup positioning--a CT based measurement of cup placement in 105 total hip arthroplasties", Int Orthop, 28, pp.198~201 (2004)
  8. Kalteis T, "Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation", J Bone Joint Surg Br, 88, pp.163~167 (2006)
  9. Leenders T, "Reduction in variability of acetabular cup abduction using computer assisted surgery: a prospective and randomized study", Comput Aided Surg, 7, pp.99~106 (2002)
  10. Honl M, "Comparison of roboticassisted and manual implantation of a primary total hip replacement. A prospective study", J Bone Joint Surg Am, 85, pp.1470~1478 (2003)
  11. Kwoh YS, "A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery", IEEE Trans Biomed Eng, 35, pp.153~160 (1988)
  12. Nishihara S, "Clinical accuracy evaluation of femoral canal preparation using the ROBODOC system", J Orthop Sci, 9, pp.452~461 (2004)
  13. Jakopec M, "The first clinical application of a hands-on robotic knee surgery system", Comput Aided Surg, 6, pp.329~339 (2001)
  14. Nolte LP, "Clinical evaluation of a system for precision enhancement in spine surgery", Clin Biomech, 10, pp.293~303 (1995)
  15. Langlots U, "Image guided cup placement. In Computer Assisted Radiology and Surgery", pp.717~721 (1999), Amsterdam: Elsevier
  16. Digioia AM, "The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment", Clin Orthop Relat Res, 355, pp.8~22 (1998)
  17. Hananouchi T, "Preoperative templating of femoral components on plain X-rays. Rotational evaluation with synthetic X-rays on ORTHODOC", Arch Orthop Trauma Surg, 127, pp.381~385 (2007)
  18. Dorr LD, "Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position", Clin Orthop Relat Res, 465, pp.92~99 (2007)
  19. Ryan JA, "Accuracy of computer navigation for acetabular component placement in THA", Clin Orthop Relat Res, 468, pp.169~177 (2010)
  20. Nishihara S, "Comparison between hand rasping and robotic milling for stem implantation in cementless total hip arthroplasty", J Arthroplasty, 21, pp.957~966 (2006)
  21. Nakamura N, "A comparison between robotic-assisted and manual implantation of cementless total hip arthroplasty", Clin Orthop Relat Res, 468, pp.1072~1081 (2010)
  22. Prymka M, "The dimensional accuracy for preparation of the femoral cavity in HIP arthroplasty. A comparison between manual- and robot-assisted implantation of hip endoprosthesis stems in cadaver femurs", Arch Orthop Trauma Surg, 126, pp.36~44 (2006)
  23. Kelley TC, "Role of navigation in total hip arthroplasty", J Bone Joint Surg Am, 91(1), pp.153~158 (2009)
  24. Parratte S, "Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study", J Bone Joint Surg Am, 89, pp.494~499 (2007)
  25. Beckmann J, "Navigated cup implantation in hip arthroplasty", Acta Orthop, 80, pp.538~544 (2009)