본문 바로가기
KERD
논문KCI 등재

Clinical Outcomes of U-blade Gamma3 Nails Used to Treat Patients with Trochanteric Fractures: Retrospective Multicenter Study

2

조회

0

다운로드

4

인용

0

참고문헌

키워드

초록

Purpose: This study was performed to assess the radiologic and clinical results of U-blade Gamma3 nail use for the treatment of trochanteric fractures. Materials and Methods: Between September 2015 and May 2018, all patients aged 65 years and older who underwent surgery with U-blade Gamma3 nails were analyzed. A total of 129 patients were selected based on having at least six months of follow-up. Image evaluations included bone quality (T-score), fracture classification on plain radiograph (AO/OTA), computed tomography configuration, union period, position of lag screw, anatomical reduction, tip apex distance (TAD), sliding extent of lag screw, change of neck shaft angle, and complications leading to reoperations were analyzed. Functional outcome were assessed using the Koval grade (ambulatory ability) at the final follow-up. Results: The mean time to union was 19.7 (range, 6-36) weeks. The screw position was centric (93 cases; 72.1%) and anatomical reduction was achieved in 74 cases (57.4%). The mean TAD was 20.3 (range, 12.3-38.1)mm. The mean sliding length of the lag screws was 3.8 (range, 0.1-12.6) mm. The mean change of neck shaft angle was 3.4。(range, 0-12.8。). Reoperations were required in two cases (1.6%) due to the cutting out of the lag screw (n=1) and metal failure with U-blade bending (n=1). Finally, Koval grades for 49.8% of patients reached preoperative status. Conclusion: Overall, use of the U-blade Gamma3 nail led to favorable clinical results, suggesting that this system may be a good option for the treatment of trochanteric fractures.

Abstract

Purpose: This study was performed to assess the radiologic and clinical results of U-blade Gamma3 nail use for the treatment of trochanteric fractures. Materials and Methods: Between September 2015 and May 2018, all patients aged 65 years and older who underwent surgery with U-blade Gamma3 nails were analyzed. A total of 129 patients were selected based on having at least six months of follow-up. Image evaluations included bone quality (T-score), fracture classification on plain radiograph (AO/OTA), computed tomography configuration, union period, position of lag screw, anatomical reduction, tip apex distance (TAD), sliding extent of lag screw, change of neck shaft angle, and complications leading to reoperations were analyzed. Functional outcome were assessed using the Koval grade (ambulatory ability) at the final follow-up. Results: The mean time to union was 19.7 (range, 6-36) weeks. The screw position was centric (93 cases; 72.1%) and anatomical reduction was achieved in 74 cases (57.4%). The mean TAD was 20.3 (range, 12.3-38.1)mm. The mean sliding length of the lag screws was 3.8 (range, 0.1-12.6) mm. The mean change of neck shaft angle was 3.4。(range, 0-12.8。). Reoperations were required in two cases (1.6%) due to the cutting out of the lag screw (n=1) and metal failure with U-blade bending (n=1). Finally, Koval grades for 49.8% of patients reached preoperative status. Conclusion: Overall, use of the U-blade Gamma3 nail led to favorable clinical results, suggesting that this system may be a good option for the treatment of trochanteric fractures.

참고문헌 (21)

  1. Stapert JW, "First experience and complications with the long Gamma nail", J Trauma, 34, pp.394~400 (1993)
  2. Corrales LA, "Variability in the assessment of fracture-healing in orthopaedic trauma studies", J Bone Joint Surg Am, 90, pp.1862~1868 (2008)
  3. Koval KJ, "Ambulatory ability after hip fracture. A prospective study in geriatric patients", Clin Orthop Relat Res, (310), pp.150~159 (1995)
  4. Koval KJ, "Functional outcome after hip fracture. Effect of general versus regional anesthesia", Clin Orthop Relat Res, (348), pp.37~41 (1998)
  5. Chang SM, "Fracture reduction with positive medial cortical support : a key element in stability reconstruction for the unstable pertrochanteric hip fractures", Arch Orthop Trauma Surg, 135, pp.811~818 (2015)
  6. Halder SC, "The Gamma nail for peritrochanteric fractures", J Bone Joint Surg Br, 74, pp.340~344 (1992)
  7. Rosenblum SF, "A biomechanical evaluation of the Gamma nail", J Bone Joint Surg Br, 74, pp.352~357 (1992)
  8. Williams WW, "Complications associated with the use of the gamma nail", Injury, 23, pp.291~292 (1992)
  9. Hesse B, "Complications following the treatment of trochanteric fractures with the gamma nail", Arch Orthop Trauma Surg, 124, pp.692~698 (2004)
  10. 김성수, "대퇴 전자간 골절에 있어 고정형 전자부 금속정, 항회전 근위 대퇴 금속정 및 3세대 감마정의 치료 비교", Hip and Pelvis, 25(3), pp.211~219 (2013), 대한고관절학회[DOI]
  11. Lang NW, "Does an additional antirotation U-Blade (RC) lag screw improve treatment of AO", OTA 31 A1-3 fractures with gamma 3 nail?, 2016, pp.47, 2733~2738
  12. Mereddy P, "The AO", ASIF proximal femoral nail antirotation(PFNA) : a new design for the treatment of unstable proximal femoral fractures, 2009, pp.40, 428~432
  13. Nobuaki Chinzei, "Comparison of the Sliding and Femoral Head Rotation among Three Different Femoral Head Fixation Devices for Trochanteric Fractures", Clinics in Orthopedic Surgery, 7(3), pp.291~297 (2015), 대한정형외과학회
  14. Chevalley F, "Gamma nailing of pertrochanteric and subtrochanteric fractures : clinical results of a series of 63 consecutive cases", J Orthop Trauma, 11, pp.412~415 (1997)
  15. Goldhagen PR, "A prospective comparative study of the compression hip screw and the gamma nail", J Orthop Trauma, 8, pp.367~372 (1994)
  16. Friedl W, "Gamma nail osteosynthesis of per- and subtrochanteric femoral fractures. 4 years experiences and their consequences for further implant development", Chirurg, 65, pp.953~963 (1994)[DOI]
  17. Forthomme JP, "Treatment of trochanteric fractures of the femur using the gamma nail (apropos of a series of 92 cases)", Acta Orthop Belg, 59, pp.22~29 (1993)[DOI]
  18. Robinson CM, "Implant-related fractures of the femur following hip fracture surgery", J Bone Joint Surg Am, 84-A, pp.1116~1122 (2002)
  19. Wang CJ, "Intramedullary femoral nails: one or two lag screws? A preliminary study", Med Eng Phys, 22, pp.613~624 (2000)
  20. 최경호, "Failure of a Rotation Control Gamma 3 Lag Screw Used to Treat a Trochanteric Fracture", Hip and Pelvis, 30(2), pp.129~133 (2018), 대한고관절학회[DOI]
  21. Loch DA, "Forces required to initiate sliding in secondgeneration intramedullary nails", J Bone Joint Surg Am, 80, pp.1626~1631 (1998)

관련 논문AI추천

이 간행물의 다른 논문 (8건)