본문 바로가기
KERD
논문KCI 등재후보

골다공증성 불안정 대퇴골 전자간 골절에서 내고정물의 종류에 따른 방사선학적 결과 비교

Comparison of the Radiologic Outcomes following the Kinds of Implants in Treating Unstable Osteoporotic Intertrochanteric Fracture

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타의약학

초록

Objectives: To determine whether kinds of implants would influence on the radiologic outcomes in the treatment of unstable osteoporotic intertrochanteric fractures. Materials and Methods: In this retrospective study, radiologic outcomes of 151 patients with unstable osteoporotic intertrochanteric fractures undergoing surgical treatments were compared based on the types of fixation implants as follows : PFNA (53 cases, group Ⅰ), gamma nail 3(31 cases, group Ⅱ), CHS with TSP (43 cases, group Ⅲ), and helical blade type LCP-DHS with TSP (24 cases, group Ⅳ). On the follow-up radiographs after operations, we assessed differences of bone union durations, neck-shaft ankle changes, lag screw or helical blade slippages, and varus alpha angle changes among the study groups. Results: All the radiologic outcomes evaluated in this study were not significantly different among the study groups. The average bone union durations of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 17.7, 18.0, 18.2, and 17.8 weeks, respectively (P=0.429). The average variation of neck-shaft angle of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 3.6o, 3.1o, 3.7o and 2.9o, respectively (P=0.273). The average lag screw or blade slippage of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 5.1 mm, 3.3 mm, 3.6 mm and 2.7 mm, respectively (P=0.154). The average variation of varus alpha of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 5.3o, 4.7o, 4.1o and 4.6º, respectively (P=0.894). Conclusions: This study indicates that four typical types of fixation implants for treating unstable osteoporotic intertrochanteric fractures would not lead to differences in postoperative radiological outcomes.

Abstract

Objectives: To determine whether kinds of implants would influence on the radiologic outcomes in the treatment of unstable osteoporotic intertrochanteric fractures. Materials and Methods: In this retrospective study, radiologic outcomes of 151 patients with unstable osteoporotic intertrochanteric fractures undergoing surgical treatments were compared based on the types of fixation implants as follows : PFNA (53 cases, group Ⅰ), gamma nail 3(31 cases, group Ⅱ), CHS with TSP (43 cases, group Ⅲ), and helical blade type LCP-DHS with TSP (24 cases, group Ⅳ). On the follow-up radiographs after operations, we assessed differences of bone union durations, neck-shaft ankle changes, lag screw or helical blade slippages, and varus alpha angle changes among the study groups. Results: All the radiologic outcomes evaluated in this study were not significantly different among the study groups. The average bone union durations of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 17.7, 18.0, 18.2, and 17.8 weeks, respectively (P=0.429). The average variation of neck-shaft angle of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 3.6o, 3.1o, 3.7o and 2.9o, respectively (P=0.273). The average lag screw or blade slippage of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 5.1 mm, 3.3 mm, 3.6 mm and 2.7 mm, respectively (P=0.154). The average variation of varus alpha of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 5.3o, 4.7o, 4.1o and 4.6º, respectively (P=0.894). Conclusions: This study indicates that four typical types of fixation implants for treating unstable osteoporotic intertrochanteric fractures would not lead to differences in postoperative radiological outcomes.

참고문헌 (18)

  1. 남우동, "90세 이상의 고령 환자에서 발생한 전자간 골절의 근위 대퇴정을 이용한 치료", Hip and Pelvis, 21(4), pp.339~344 (2009), 대한고관절학회
  2. Parker MJ, "A new mobility score for predicting mortality after hip fracture", J Bone Joint Surg Br, 75, pp.797~798 (1993)
  3. 김용식, "심한 골다공증 환자에서 압박 고 나사 금속판을 이용한 대퇴 전자간 골절의 치료", Hip and Pelvis, 21(1), pp.29~34 (2009), 대한고관절학회
  4. 노재영, "불안정성 대퇴골 전자간 골절의 치료에서 항회전 근위 대퇴 골수정과 전자부 안정화 금속판을 이용한 압박 고 나사의 비교", 대한골절학회지, 23(2), pp.161~166 (2010), 대한골절학회
  5. Aune AK, "Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperation in a prospective, randomized study of 378 patients", Acta Orthop Scand, 65, pp.127~130 (1994)
  6. Babst R, "Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures", J Orthop Trauma, 12, pp.392~399 (1998)
  7. Lorich DG, "Osteoporotic pertrochanteric hip fractures: management and current controversies", Instr Course Lect, 53, pp.441~454 (2004)
  8. Buciuto R, "RAB-plate vs Richards CHS plate for unstable trochanteric hip fractures. A randomized study of 233 patients with 1-year follow-up", Acta Orthop Scand, 69, pp.25~28 (1998)
  9. Madsen JE, "Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw", J Orthop Trauma, 12, pp.241~248 (1998)
  10. Su ET, "The effect of an attachable lateral support plate on the stability of intertrochanteric fracture fixation with a sliding hip screw", J Trauma, 55, pp.504~508 (2003)
  11. Sommers MB, "A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation", J Orthop Trauma, 18, pp.361~368 (2004)
  12. Swiontkowski MF, "Torsion and bending analysis of internal fixation techniques for femoral neck fractures: the role of implant design and bone density", J Orthop Res, 5, pp.433~444 (1987)
  13. Simmermacher RK, "The AO", ASIF-proximal femoral nail (PFN): a new device for the treatment of unstable proximal femoral fractures, 1999, pp.30, 327~332
  14. Windolf, M, "Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation", Clin Biomech, 24, pp.59~64 (2009)
  15. Strauss E, "Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a Biomechanical evaluation", Injury, 37, pp.984~989 (2006)
  16. Ahrengart L, "A randomized study of the compression hip screw and Gamma nail in 426 fractures", Clin Orthop Relat Res, 401, pp.209~222 (2002)
  17. Niemeyer P, "Principles and clinical application of the locking compression plate (LCP)", Acta Chir Orthop Traumatol Cech, 73, pp.221~228 (2006)
  18. Jewell DP, "Locking plates increase the strength of dynamic hip screws", Injury, 39, pp.209~212 (2008)

관련 논문AI추천

이 간행물의 다른 논문 (5건)