골다공증성 불안정 대퇴골 전자간 골절에서 내고정물의 종류에 따른 방사선학적 결과 비교
Comparison of the Radiologic Outcomes following the Kinds of Implants in Treating Unstable Osteoporotic Intertrochanteric Fracture
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: To determine whether kinds of implants would influence on the radiologic outcomes in the treatment of unstable osteoporotic intertrochanteric fractures. Materials and Methods: In this retrospective study, radiologic outcomes of 151 patients with unstable osteoporotic intertrochanteric fractures undergoing surgical treatments were compared based on the types of fixation implants as follows : PFNA (53 cases, group Ⅰ), gamma nail 3(31 cases, group Ⅱ), CHS with TSP (43 cases, group Ⅲ), and helical blade type LCP-DHS with TSP (24 cases, group Ⅳ). On the follow-up radiographs after operations, we assessed differences of bone union durations, neck-shaft ankle changes, lag screw or helical blade slippages, and varus alpha angle changes among the study groups. Results: All the radiologic outcomes evaluated in this study were not significantly different among the study groups. The average bone union durations of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 17.7, 18.0, 18.2, and 17.8 weeks, respectively (P=0.429). The average variation of neck-shaft angle of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 3.6o, 3.1o, 3.7o and 2.9o, respectively (P=0.273). The average lag screw or blade slippage of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 5.1 mm, 3.3 mm, 3.6 mm and 2.7 mm, respectively (P=0.154). The average variation of varus alpha of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 5.3o, 4.7o, 4.1o and 4.6º, respectively (P=0.894). Conclusions: This study indicates that four typical types of fixation implants for treating unstable osteoporotic intertrochanteric fractures would not lead to differences in postoperative radiological outcomes.
Abstract
Objectives: To determine whether kinds of implants would influence on the radiologic outcomes in the treatment of unstable osteoporotic intertrochanteric fractures. Materials and Methods: In this retrospective study, radiologic outcomes of 151 patients with unstable osteoporotic intertrochanteric fractures undergoing surgical treatments were compared based on the types of fixation implants as follows : PFNA (53 cases, group Ⅰ), gamma nail 3(31 cases, group Ⅱ), CHS with TSP (43 cases, group Ⅲ), and helical blade type LCP-DHS with TSP (24 cases, group Ⅳ). On the follow-up radiographs after operations, we assessed differences of bone union durations, neck-shaft ankle changes, lag screw or helical blade slippages, and varus alpha angle changes among the study groups. Results: All the radiologic outcomes evaluated in this study were not significantly different among the study groups. The average bone union durations of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 17.7, 18.0, 18.2, and 17.8 weeks, respectively (P=0.429). The average variation of neck-shaft angle of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 3.6o, 3.1o, 3.7o and 2.9o, respectively (P=0.273). The average lag screw or blade slippage of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 5.1 mm, 3.3 mm, 3.6 mm and 2.7 mm, respectively (P=0.154). The average variation of varus alpha of the group Ⅰ, Ⅱ, Ⅲ and Ⅳ were 5.3o, 4.7o, 4.1o and 4.6º, respectively (P=0.894). Conclusions: This study indicates that four typical types of fixation implants for treating unstable osteoporotic intertrochanteric fractures would not lead to differences in postoperative radiological outcomes.
참고문헌 (18)
- 남우동, "90세 이상의 고령 환자에서 발생한 전자간 골절의 근위 대퇴정을 이용한 치료", Hip and Pelvis, 21(4), pp.339~344 (2009), 대한고관절학회
- Parker MJ, "A new mobility score for predicting mortality after hip fracture", J Bone Joint Surg Br, 75, pp.797~798 (1993)
- 김용식, "심한 골다공증 환자에서 압박 고 나사 금속판을 이용한 대퇴 전자간 골절의 치료", Hip and Pelvis, 21(1), pp.29~34 (2009), 대한고관절학회
- 노재영, "불안정성 대퇴골 전자간 골절의 치료에서 항회전 근위 대퇴 골수정과 전자부 안정화 금속판을 이용한 압박 고 나사의 비교", 대한골절학회지, 23(2), pp.161~166 (2010), 대한골절학회
- Aune AK, "Gamma nail vs compression screw for trochanteric femoral fractures. 15 reoperation in a prospective, randomized study of 378 patients", Acta Orthop Scand, 65, pp.127~130 (1994)
- Babst R, "Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures", J Orthop Trauma, 12, pp.392~399 (1998)
- Lorich DG, "Osteoporotic pertrochanteric hip fractures: management and current controversies", Instr Course Lect, 53, pp.441~454 (2004)
- Buciuto R, "RAB-plate vs Richards CHS plate for unstable trochanteric hip fractures. A randomized study of 233 patients with 1-year follow-up", Acta Orthop Scand, 69, pp.25~28 (1998)
- Madsen JE, "Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw", J Orthop Trauma, 12, pp.241~248 (1998)
- Su ET, "The effect of an attachable lateral support plate on the stability of intertrochanteric fracture fixation with a sliding hip screw", J Trauma, 55, pp.504~508 (2003)
- Sommers MB, "A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation", J Orthop Trauma, 18, pp.361~368 (2004)
- Swiontkowski MF, "Torsion and bending analysis of internal fixation techniques for femoral neck fractures: the role of implant design and bone density", J Orthop Res, 5, pp.433~444 (1987)
- Simmermacher RK, "The AO", ASIF-proximal femoral nail (PFN): a new device for the treatment of unstable proximal femoral fractures, 1999, pp.30, 327~332
- Windolf, M, "Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation", Clin Biomech, 24, pp.59~64 (2009)
- Strauss E, "Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: a Biomechanical evaluation", Injury, 37, pp.984~989 (2006)
- Ahrengart L, "A randomized study of the compression hip screw and Gamma nail in 426 fractures", Clin Orthop Relat Res, 401, pp.209~222 (2002)
- Niemeyer P, "Principles and clinical application of the locking compression plate (LCP)", Acta Chir Orthop Traumatol Cech, 73, pp.221~228 (2006)
- Jewell DP, "Locking plates increase the strength of dynamic hip screws", Injury, 39, pp.209~212 (2008)
