Purpose: A novel and simple method to ensure accurate acetabular component anteversion and inclination intraoperatively with the use of a transparency template is described. Materials and Methods: Patients who underwent total hip arthroplasty (THA) via direct anterior approach (DAA) from June 2019 to January 2020 were included. A transparency template that can be placed over the image intensifier monitor to allow surgeons an accurate reading of the acetabular component position intraoperatively was designed, developed and utilized to determine effectiveness. The first template consists of two perpendicular lines indicating the “trans-ischial line” and the “pubic symphysis/coccyx”. The second template consist of a line indicating 45。inclination and parallel lines of corresponding distances apart required to achieve 20。anteversion based on Lewinnek’s formula: version=sin-1 (D1/D2), where D1: minor axis and D2: major axis of the component. This template was used throughout the acetabular part of the surgery, from reaming to impaction of component. Postoperative acetabular inclination, anteversion, surgical duration, length of stay, as well as complications were recorded. Results: Twenty-six patients were included in this study. Mean postoperative acetabular cup inclination was 43.46±3.09。and mean version was 19.98±2.89。. A total of 21 patients (80.8%) fell within the Callanan safe zone and all 26 patients (100%) were within the Lewinnek safe zone. Conclusion: The transparency template is a simple, reproducible, and effective tool with a minimal learning curve and no requirement for expensive equipment. This template has the potential to assist surgeons, especially those who are less experienced with DAA THA, in obtaining better postoperative radiographic outcomes.

Abstract

Purpose: A novel and simple method to ensure accurate acetabular component anteversion and inclination intraoperatively with the use of a transparency template is described. Materials and Methods: Patients who underwent total hip arthroplasty (THA) via direct anterior approach (DAA) from June 2019 to January 2020 were included. A transparency template that can be placed over the image intensifier monitor to allow surgeons an accurate reading of the acetabular component position intraoperatively was designed, developed and utilized to determine effectiveness. The first template consists of two perpendicular lines indicating the “trans-ischial line” and the “pubic symphysis/coccyx”. The second template consist of a line indicating 45。inclination and parallel lines of corresponding distances apart required to achieve 20。anteversion based on Lewinnek’s formula: version=sin-1 (D1/D2), where D1: minor axis and D2: major axis of the component. This template was used throughout the acetabular part of the surgery, from reaming to impaction of component. Postoperative acetabular inclination, anteversion, surgical duration, length of stay, as well as complications were recorded. Results: Twenty-six patients were included in this study. Mean postoperative acetabular cup inclination was 43.46±3.09。and mean version was 19.98±2.89。. A total of 21 patients (80.8%) fell within the Callanan safe zone and all 26 patients (100%) were within the Lewinnek safe zone. Conclusion: The transparency template is a simple, reproducible, and effective tool with a minimal learning curve and no requirement for expensive equipment. This template has the potential to assist surgeons, especially those who are less experienced with DAA THA, in obtaining better postoperative radiographic outcomes.

참고문헌 (29)

  1. "Obesity and overweight" (2020)[URL]
  2. Kurtz S, "Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030", J Bone Joint Surg Am, 89, pp.780~785 (2007)
  3. 장준동, "The Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications", Hip and Pelvis, 29(1), pp.1~14 (2017), 대한고관절학회[DOI]
  4. Deep K, "Computer assisted navigation in total knee and hip arthroplasty", SICOT J, 3, pp.50~ (2017)
  5. Barrett WP, "Prospective randomized study of direct anterior vs postero-lateral approach for total hip arthroplasty", J Arthroplasty, 28, pp.1634~1638 (2013)
  6. Martin CT, "A comparison of hospital length of stay and short-term morbidity between the ante rior and the posterior approaches to total hip arthroplasty", J Arthroplasty, 28, pp.849~854 (2013)
  7. Higgins BT, "posterior approach for total hip arthroplasty, a systematic review and meta-analysis", J Arthroplasty, 30, pp.419~434 (2015)
  8. Lewinnek GE, "Dislocations after total hip-replacement arthroplasties", J Bone Joint Surg Am, 60, pp.217~220 (1978)
  9. Siebenrock KA, "Effect of pelvic tilt on acetabular retroversion : a study of pelves from cadavers", Clin Orthop Relat Res, (407), pp.241~248 (2003)
  10. Tannast M, "Estimation of pelvic tilt on anteroposterior X-rays--a comparison of six parameters", Skeletal Radiol, 35, pp.149~155 (2006)
  11. Liaw CK, "A new tool for measuring cup orientation in total hip arthroplasties from plain radiographs", Clin Orthop Relat Res, 451, pp.134~139 (2006)
  12. Biedermann R, "Reducing the risk of dislocation after total hip arthroplasty : the effect of orientation of the acetabular component", J Bone Joint Surg Br, 87, pp.762~769 (2005)
  13. Beverland DE, "Placement of the acetabular component", Bone Joint J., 98-B(1 Suppl A), pp.37~43 (2016)
  14. Little NJ, "Acetabular polyethylene wear and acetabular inclination and femoral offset", Clin Orthop Relat Res, 467, pp.2895~2900 (2009)
  15. Asayama I, "Reconstructed hip joint position and abductor muscle strength after total hip arthroplasty", J Arthroplasty, 20, pp.414~420 (2005)
  16. Ranawat CS, "Correction of limb-length inequality during total hip arthroplasty", J Arthroplasty, 16, pp.715~720 (2001)
  17. Kurtz WB, "Factors affecting bony impingement in hip arthroplasty", J Arthroplasty, 25, pp.624~634 (2010)
  18. Bolland BJ, "Indications for early hip revision surgery in the UK--a re-analysis of NJR data", Hip Int, 22, pp.145~152 (2012)
  19. Bozic KJ, "Risk of complication and revision total hip arthroplasty among Medicare patients with different bearing surfaces", Clin Orthop Relat Res, 468, pp.2357~2362 (2010)
  20. Callanan MC, "The John Charnley Award : risk factors for cup malpositioning : quality improvement through a joint registry at a tertiary hospital", Clin Orthop Relat Res, 469, pp.319~329 (2011)
  21. Soderquist MC, "Acetabular placement accuracy with the direct anterior approach freehand technique", J Arthroplasty, 32, pp.2748~2754 (2017)
  22. Slotkin EM, "Accuracy of fluoroscopic guided acetabular component positioning during direct anterior total hip arthroplasty", J Arthroplasty, 30(9Suppl), pp.102~106 (2015)
  23. Buckland AJ, "Acetabular anteversion changes due to spinal deformity correction : bridging the gap between hip and spine surgeons", J Bone Joint Surg Am, 97, pp.1913~1920 (2015)
  24. Anda S, "Pelvic inclination and spatial orientation of the acetabulum. A radiographic, computed tomographic and clinical investigation", Acta Radiol, 31, pp.389~394 (1990)
  25. Dorr LD, "Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position", Clin Orthop Relat Res, 465, pp.92~99 (2007)
  26. Ohmori T, "The optimal combined anteversion pattern to achieve a favorable impingement-free angle in total hip arthroplasty", J Orthop Sci, 24, pp.474~481 (2019)
  27. Dorr LD, "Combined anteversion technique for total hip arthroplasty", Clin Orthop Relat Res, 467, pp.119~127 (2009)
  28. Lee GC, "Accuracy of planar anteversion measurements using anteroposterior radiographs", BMC Musculoskelet Disord, 20, pp.586~ (2019)
  29. Nho JH, "Reliability and validity of measuring version of the acetabular component", J Bone Joint Surg Br, 94, pp.32~36 (2012)

관련 논문AI추천

이 간행물의 다른 논문 (7건)