본문 바로가기
KERD
논문KCI 등재

Is Restoration of Hip Center Mandatory for Total Hip Arthroplasty of Protrusio Acetabuli?

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

Purpose: While initial fixation using a press-fit of the acetabular cup is critical for the durability of the component, restoration of the hip center is regarded as an attributable factor for implant survival and successful outcome. In protrusio acetabuli (PA), obtaining both restoration of the hip center and the press-fit of the acetabular cup simultaneously might be difficult during total hip arthroplasty (THA). We tested the hypothesis that use of a medialized cup, if press-fitted, will not result in compromise of the implant stability and outcome after cementless THA of PA. Materials and Methods: A total of 26 cementless THAs of 22 patients with PA were reviewed. During THA, press-fit of the cup was prioritized rather than hip center restoration. A press-fit was obtained in 24 hips. A pressfit could not be obtained in the two remaining hips; therefore, reinforcement acetabular components were used. Restoration of the hip center was achieved in 17 cups; 15 primary cups and two reinforcement components; it was medialized in nine cups. Implant stability and modified Harris hip score (mHHS) between the two groups were compared at a mean follow-up of 5.1 years (range, 2-16 years). Results: Twenty-six cups; 17 restored cups and nine medialized press-fitted cups, remained stable at the latest follow-up. A similar final mHHS was observed between the restored group and the medialized group (83.6±12.1 vs 83.8±10.4, P=0.786). Conclusion: Implant stability and favorable results were obtained by press-fitted cups, irrespective of hip center restoration. THA in PA patients showed promising clinical and radiological results.

Abstract

Purpose: While initial fixation using a press-fit of the acetabular cup is critical for the durability of the component, restoration of the hip center is regarded as an attributable factor for implant survival and successful outcome. In protrusio acetabuli (PA), obtaining both restoration of the hip center and the press-fit of the acetabular cup simultaneously might be difficult during total hip arthroplasty (THA). We tested the hypothesis that use of a medialized cup, if press-fitted, will not result in compromise of the implant stability and outcome after cementless THA of PA. Materials and Methods: A total of 26 cementless THAs of 22 patients with PA were reviewed. During THA, press-fit of the cup was prioritized rather than hip center restoration. A press-fit was obtained in 24 hips. A pressfit could not be obtained in the two remaining hips; therefore, reinforcement acetabular components were used. Restoration of the hip center was achieved in 17 cups; 15 primary cups and two reinforcement components; it was medialized in nine cups. Implant stability and modified Harris hip score (mHHS) between the two groups were compared at a mean follow-up of 5.1 years (range, 2-16 years). Results: Twenty-six cups; 17 restored cups and nine medialized press-fitted cups, remained stable at the latest follow-up. A similar final mHHS was observed between the restored group and the medialized group (83.6±12.1 vs 83.8±10.4, P=0.786). Conclusion: Implant stability and favorable results were obtained by press-fitted cups, irrespective of hip center restoration. THA in PA patients showed promising clinical and radiological results.

참고문헌 (39)

  1. Armbuster TG, "The adult hip : an anatomic study. Part I : the bony landmarks", Radiology, 128, pp.1~10 (1978)
  2. Guerra J Jr, "The adult hip : an anatomic study. Part II : the soft-tissue landmarks", Radiology, 128, pp.11~20 (1978)
  3. Hastings DE, "Protrusio acetabuli in rheumatoid arthritis", Clin Orthop Relat Res, (108), pp.76~83 (1975)
  4. McBride MT, "Protrusio acetabuli : diagnosis and treatment", J Am Acad Orthop Surg, 9, pp.79~88 (2001)
  5. Mullaji AB, "Acetabular protrusio: surgical technique of dealing with a problem in depth", Bone Joint J, 95-B(11 Suppl A), pp.37~40 (2013)
  6. Baghdadi YM, "Long-term results of the uncemented acetabular component in a primary total hip arthroplasty performed for protrusio acetabuli : a fifteen year median follow-up", Int Orthop, 39, pp.839~845 (2015)
  7. Kondo K, "Total hip arthroplasty with bone graft for acetabular protrusion in rheumatoid arthritis", Mod Rheumatol, 12, pp.219~225 (2002)
  8. Krushell RJ, "Primary total hip arthroplasty using a dual-geometry cup to treat protrusio acetabuli", J Arthroplasty, 23, pp.1128~1131 (2008)
  9. Zhen P, "Total hip arthroplasty to treat acetabular protrusions secondary to rheumatoid arthritis", J Orthop Surg Res, 13, pp.92~ (2018)
  10. Baghdadi YM, "Restoration of the hip center during THA performed for protrusio acetabuli is associated with better implant survival", Clin Orthop Relat Res, 471, pp.3251~3259 (2013)
  11. Bayley JC, "Long-term results of total hip arthroplasty in protrusio acetabuli", J Arthroplasty, 2, pp.275~279 (1987)
  12. Ranawat CS, "Role of bone grafting in correction of protrusio acetabuli by total hip arthroplasty", J Arthroplasty, 1, pp.131~137 (1986)
  13. Charnley J, "Total hip replacement by low-friction arthroplasty", Clin Orthop Relat Res, 72, pp.7~21 (1970)
  14. Sotelo-Garza A, "The results of Charnley arthroplasty of hip performed for protrusio acetabuli", Clin Orthop Relat Res, (132), pp.12~18 (1978)
  15. 신종기, "Accuracy and Reliability of Preoperative On-screen Templating Using Digital Radiographs for Total Hip Arthroplasty", Hip and Pelvis, 28(4), pp.201~207 (2016), 대한고관절학회[DOI]
  16. Ha YC, "Acetabular component positioning using anatomic landmarks of the acetabulum", Clin Orthop Relat Res, 470, pp.3515~3523 (2012)
  17. von Langenbeck B, "Ueber die Schussverletzungen des Hüftgelenks", Arch Klin Chir, 16, pp.263~339 (1874)
  18. Won SH, "Improving preoperative planning for complex total hip replacement with a Rapid Prototype model enabling surgical simulation", Bone Joint J, 95-B, pp.1458~1463 (2013)
  19. Woolson ST, "Comparison of primary total hip replacements performed with a standard incision or a mini-incision", J Bone Joint Surg Am, 86, pp.1353~1358 (2004)
  20. Widmer KH, "Compliant positioning of total hip components for optimal range of motion", J Orthop Res, 22, pp.815~821 (2004)
  21. Parvizi J, "Thirty-day mortality following hip arthroplasty for acute fracture", J Bone Joint Surg Am, 86, pp.1983~1988 (2004)
  22. Ji HM, "Dislocation after total hip arthroplasty : a randomized clinical trial of a posterior approach and a modified lateral approach", J Arthroplasty, 27, pp.378~385 (2012)
  23. Engh CA, "Cementless acetabular components", J Bone Joint Surg Br, 72, pp.53~59 (1990)
  24. Woo RY, "Dislocations after total hip arthroplasty", J Bone Joint Surg Am, 64, pp.1295~1306 (1982)
  25. Nho JH, "Reliability and validity of measuring version of the acetabular component", J Bone Joint Surg Br, 94, pp.32~36 (2012)
  26. Woolson ST, "Results of a method of leg-length equalization for patients undergoing primary total hip replacement", J Arthroplasty, 14, pp.159~164 (1999)
  27. Latimer HA, "Porous-coated acetabular components with screw fixation. Five to ten-year results", J Bone Joint Surg Am, 78, pp.975~981 (1996)
  28. Engh CA, "The case for porouscoated hip implants. The femoral side", Clin Orthop Relat Res, (261), pp.63~81 (1990)
  29. Livermore J, "Effect of femoral head size on wear of the polyethylene acetabular component", J Bone Joint Surg Am, 72, pp.518~528 (1990)
  30. Engh CA, "Porous-coated total hip replacement", Clin Orthop Relat Res, (298), pp.89~96 (1994)
  31. DeLee JG, "Radiological demarcation of cemented sockets in total hip replacement", Clin Orthop Relat Res, (121), pp.20~32 (1976)
  32. Gruen TA, ""Modes of failure"of cemented stem-type femoral components : a radiographic analysis of loosening", Clin Orthop Relat Res, (141), pp.17~27 (1979)
  33. Byrd JW, "Prospective analysis of hip arthroscopy with 2-year follow-up", Arthroscopy, 16, pp.578~587 (2000)
  34. Ranawat CS, "Total hip arthroplasty in protrusio acetabuli of rheumatoid arthritis", J Bone Joint Surg Am, 62, pp.1059~1065 (1980)
  35. McCollum DE, "Bone-grafting in total hip replacement for acetabular protrusion", J Bone Joint Surg Am, 62, pp.1065~1073 (1980)
  36. McGann WA, "Acetabular preparation in cementless revision total hip arthroplasty", Clin Orthop Relat Res, (235), pp.35~46 (1988)
  37. Garbuz D, "Classification and reconstruction in revision acetabular arthroplasty with bone stock deficiency", Clin Orthop Relat Res, (324), pp.98~107 (1996)
  38. Tabata T, "Initial stability of cementless acetabular cups : press-fit and screw fixation interaction--an in vitro biomechanical study", Eur J Orthop Surg Traumatol, 25, pp.497~502 (2015)
  39. Terrier A, "Benefit of cup medialization in total hip arthroplasty is associated with femoral anatomy", Clin Orthop Relat Res, 472, pp.3159~3165 (2014)

관련 논문AI추천

이 간행물의 다른 논문 (6건)