Total Hip Arthroplasty with Cemented Dual Mobility Cup into a Fully Porous Multihole Cup with Variable Angle Locking Screws for Acetabular Fractures in the Frail Elderly
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose: The purpose was to examine the clinical and radiological outcomes after surgical treatment of acetabular fractures with total hip arthroplasty with a dual mobility cup cemented into a porous multihole cup in the population of frail elderly patients. Materials and Methods: A retrospective review of 16 patients who underwent surgery (mean age, 76.7 years) with a mean follow-up period of 36.9 months was conducted. Following surgery, patients underwent postoperative follow-up at six weeks, thre e, six, and 12 months and clinical and radiological examinations were performed. Results: Classification of fractures was based on the Letournel classification. Following surgery, all patients were allowed weight-bearing as tolerated immediately postoperative. Fourteen patients showed maintenance of preoperative mobility status at one year. The mean Harris hip score was 64.8 (range, 34.7-82.8) and 80.0 (range, 60.8-93.8) at three months and one year, respectively. The mortality rate was 12.5% at one year (2/16). Complications included heterotopic ossification (2/16), deep venous thrombosis (1/16), heamatoma (1/16), and femoral revision due to a Vancouver B2 fracture (1/16). No case of deep infection, dislocation, or implant loosening was reported. Conclusion: Total hip arthroplasty using a dual mobility cup cemented into a porous multihole cup with locking screws resulted in a stable construct with a capacity for immediate weight-bearing as tolerated with rapid relief of pain. The findings of this study suggest that this procedure can be regarded as a safe method that has shown promising clinical and radiological outcomes for treatment of patients with medical frailty.
Abstract
Purpose: The purpose was to examine the clinical and radiological outcomes after surgical treatment of acetabular fractures with total hip arthroplasty with a dual mobility cup cemented into a porous multihole cup in the population of frail elderly patients. Materials and Methods: A retrospective review of 16 patients who underwent surgery (mean age, 76.7 years) with a mean follow-up period of 36.9 months was conducted. Following surgery, patients underwent postoperative follow-up at six weeks, thre e, six, and 12 months and clinical and radiological examinations were performed. Results: Classification of fractures was based on the Letournel classification. Following surgery, all patients were allowed weight-bearing as tolerated immediately postoperative. Fourteen patients showed maintenance of preoperative mobility status at one year. The mean Harris hip score was 64.8 (range, 34.7-82.8) and 80.0 (range, 60.8-93.8) at three months and one year, respectively. The mortality rate was 12.5% at one year (2/16). Complications included heterotopic ossification (2/16), deep venous thrombosis (1/16), heamatoma (1/16), and femoral revision due to a Vancouver B2 fracture (1/16). No case of deep infection, dislocation, or implant loosening was reported. Conclusion: Total hip arthroplasty using a dual mobility cup cemented into a porous multihole cup with locking screws resulted in a stable construct with a capacity for immediate weight-bearing as tolerated with rapid relief of pain. The findings of this study suggest that this procedure can be regarded as a safe method that has shown promising clinical and radiological outcomes for treatment of patients with medical frailty.
참고문헌 (32)
- Dana C. Mears, "Surgical Treatment of Acetabular Fractures in Elderly Patients With Osteoporotic Bone", Journal of the American Academy of Orthopaedic Surgeons, 7(2), pp.128~141 (1999), Ovid Technologies (Wolters Kluwer Health)[DOI]
- T. A. Ferguson, "Fractures of the acetabulum in patients aged 60 years and older", The Journal of Bone and Joint Surgery. British volume, 92-B(2), pp.250~257 (2010), British Editorial Society of Bone & Joint Surgery[DOI]
- Cynthia M. Harper, "Physiology and Complications of Bed Rest", Journal of the American Geriatrics Society, 36(11), pp.1047~1054 (1988), Wiley[DOI]
- Narender Kumar Magu, "Conservatively treated acetabular fractures: A retrospective analysis", Indian Journal of Orthopaedics, 46(1), pp.36~45 (2012), Springer Science and Business Media LLC[DOI]
- Johannes Wollmerstädt, "Mortality, complications and long-term functional outcome in elderly patients with fragility fractures of the acetabulum", BMC Geriatrics, 20(1) (2020), Springer Science and Business Media LLC[DOI]
- Joshua L. Gary, "Survivorship of the native hip joint after percutaneous repair of acetabular fractures in the elderly", Injury, 42(10), pp.1144~1151 (2011), Elsevier BV[DOI]
- P. V. Giannoudis, "Operative treatment of displaced fractures of the acetabulum", The Journal of Bone and Joint Surgery. British volume, 87-B(1), pp.2~9 (2005), British Editorial Society of Bone & Joint Surgery[DOI]
- MARTIN WEBER, "Total Hip Arthroplasty after Operative Treatment of an Acetabular Fracture*", The Journal of Bone & Joint Surgery, 80(9), pp.1295~1305 (1998), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Antomio Capone, "Surgical treatment of acetabular fractures in the elderly: a systematic review of the results", EFORT Open Reviews, 2(4), pp.97~103 (2017), Bioscientifica[DOI]
- J. S. Daurka, "Acetabular fractures in patients aged > 55 years", The Bone & Joint Journal, 96-B(2), pp.157~163 (2014), British Editorial Society of Bone & Joint Surgery[DOI]
- Umberto Giovanni De Bellis, "Acute total hip replacement for acetabular fractures: A systematic review of the literature", Injury, 45(2), pp.356~361 (2014), Elsevier BV[DOI]
- Dana C. Mears, "Acute Total Hip Arthroplasty for Selected Displaced Acetabular Fractures", The Journal of Bone and Joint Surgery-American Volume, 84(1), pp.1~9 (2002), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Julio J. Jauregui, "Acute total hip arthroplasty for older patients with acetabular fractures: A meta-analysis", Journal of Clinical Orthopaedics and Trauma, 11(6), pp.976~982 (2020), Elsevier BV[DOI]
- Deepak Gautam, "Total hip arthroplasty in acetabular fractures", Journal of Clinical Orthopaedics and Trauma, 11(6), pp.1090~1098 (2020), Elsevier BV[DOI]
- R M. D Meek, "Epidemiology of Dislocation after Total Hip Arthroplasty", Clinical Orthopaedics & Related Research, 447, pp.9~18, Ovid Technologies (Wolters Kluwer Health)[DOI]
- Preetesh D. Patel, "The dislocating hip arthroplasty: prevention and treatment", The Journal of Arthroplasty, 22(4), pp.86~90 (2007), Elsevier BV[DOI]
- B. Darrith, "Outcomes of dual mobility components in total hip arthroplasty", The Bone & Joint Journal, 100-B(1), pp.11~19 (2018), British Editorial Society of Bone & Joint Surgery[DOI]
- I. De Martino, "Dislocation following total hip arthroplasty using dual mobility acetabular components", The Bone & Joint Journal, 99-B(1_Supple_A), pp.18~24 (2017), British Editorial Society of Bone & Joint Surgery[DOI]
- Matthew P. Abdel, "Dual-Mobility Constructs in Revision Total Hip Arthroplasties", The Journal of Arthroplasty, 33(5), pp.1328~1330 (2018), Elsevier BV[DOI]
- Darren R. Plummer, "Dual-Mobility Articulations for Patients at High Risk for Dislocation", The Journal of Arthroplasty, 31(9), pp.131~135 (2016), Elsevier BV[DOI]
- Jesús Moreta, "Cementation of a dual-mobility cup into a well-fixed cementless shell in patients with high risk of dislocation undergoing revision total hip arthroplasty", HIP International, 31(1), pp.97~102 (2019), SAGE Publications[DOI]
- Jonathan A. Gabor, "Cementation of a monoblock dual mobility bearing in a newly implanted porous revision acetabular component in patients undergoing revision total hip arthroplasty", Arthroplasty Today, 5(3), pp.341~347 (2019), Elsevier BV[DOI]
- Perry Evangelista, "Do Cemented Dual-Mobility Cups Confer Stability for Patients at High Risk of Dislocation in Revision Total Hip Arthroplasty?", The Journal of Hip Surgery, 02(02), pp.088~091 (2018), Georg Thieme Verlag KG[DOI]
- Letournel E, "Acetabulum fractures : classification and management", Clin Orthop Relat Res, (151), pp.81~106 (1980)
- Wasielewski RC, "Acetabular anatomy and the transacetabular fixation of screws in total hip arthroplasty", J Bone Joint Surg Am, 72, pp.501~508 (1990)
- Patrick D.G. Henry, "The Osteoporotic Acetabular Fracture", Orthopedic Clinics of North America, 44(2), pp.201~215 (2013), Elsevier BV[DOI]
- Jan Tidermark, "Primary Total Hip Arthroplasty with a Burch-Schneider Antiprotrusion Cage and Autologous Bone Grafting for Acetabular Fractures in Elderly Patients", Journal of Orthopaedic Trauma, 17(3), pp.193~197 (2003), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Anders Enocson, "Acetabular Fractures in the Elderly Treated With a Primary Burch–Schneider Reinforcement Ring, Autologous Bone Graft, and a Total Hip Arthroplasty", Journal of Orthopaedic Trauma, 28(6), pp.330~337 (2014), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Frank Liaw, "Primary total hip replacement using Burch-Schneider cages for acetabular fractures", HIP International, 32(3), pp.401~406 (2020), SAGE Publications[DOI]
- Snir Heller, "Locking versus standard screw fixation for acetabular cups: is there a difference?", Archives of Orthopaedic and Trauma Surgery, 133(5), pp.701~705 (2013), Springer Science and Business Media LLC[DOI]
- George J. Haidukewych, "Innovations in Locking Plate Technology", Journal of the American Academy of Orthopaedic Surgeons, 12(4), pp.205~212 (2004), Ovid Technologies (Wolters Kluwer Health)[DOI]
- Lachlan P. Milne, "Polyaxial Locking and Compression Screws Improve Construct Stiffness of Acetabular Cup Fixation: A Biomechanical Study", The Journal of Arthroplasty, 29(5), pp.1043~1051 (2014), Elsevier BV[DOI]
