균열치아 진단에서 정량광형광(Quantitative Light-Induced fluorescent(QLF))장비의 활용

Clinical Application of Quantitative Light-Induced fluorescent(QLF) device in the Diagnosis of cracked teeth

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

As social interest in health increases, interest in oral health and preservation of natural teeth are also increasing. The hard tissues in the oral cavity undergo physical changes as age increases. One of the changes is the progress of tooth cracks in natural or restored teeth. These cracks are commonly encountered in daily clinical practice but often confuse the operator due to its difficulties in diagnosis and therapeutic access. Diagnosing a cracked tooth has been a chanllenge to dental clinicians. For the diagnosis of a cracked tooth, the quantitative light-induced fluorescent (QLF) device, which is capable of detecting fluorescent reactions of the tooth with visible light (405nm), has been introduced as one of the methods for observing tooth cracks. Specific metabolites of microorganisms that penetrate through the crack’s line react with specific autofluorescence to 405nm visible light emitted from the QLF device. These fluorescent image provided by the QLF helps to observe the location of the crack during the diagnosis of a cracked tooth and helps the patient’s dental record. The QLF images provided a magnified image as well as a fluorescent image that could identify the location of the crack existing outside the tooth, around the restoration, and inside the cavity after removal of the restoration by a simple process of capturing images. This report shows the process of diagnosis of a cracked tooth using a QLF device by observing three separate cases which can help clinicians to understand this process.

Abstract

As social interest in health increases, interest in oral health and preservation of natural teeth are also increasing. The hard tissues in the oral cavity undergo physical changes as age increases. One of the changes is the progress of tooth cracks in natural or restored teeth. These cracks are commonly encountered in daily clinical practice but often confuse the operator due to its difficulties in diagnosis and therapeutic access. Diagnosing a cracked tooth has been a chanllenge to dental clinicians. For the diagnosis of a cracked tooth, the quantitative light-induced fluorescent (QLF) device, which is capable of detecting fluorescent reactions of the tooth with visible light (405nm), has been introduced as one of the methods for observing tooth cracks. Specific metabolites of microorganisms that penetrate through the crack’s line react with specific autofluorescence to 405nm visible light emitted from the QLF device. These fluorescent image provided by the QLF helps to observe the location of the crack during the diagnosis of a cracked tooth and helps the patient’s dental record. The QLF images provided a magnified image as well as a fluorescent image that could identify the location of the crack existing outside the tooth, around the restoration, and inside the cavity after removal of the restoration by a simple process of capturing images. This report shows the process of diagnosis of a cracked tooth using a QLF device by observing three separate cases which can help clinicians to understand this process.

참고문헌 (12)

  1. Ellis SG, "Incomplete tooth fracture-proposal for a new definition", Br Dent J, 190, pp.424~428 (2001)
  2. "Endodontics: colleagues for excellence" (2008), American Association of Endodontists
  3. Banerji S, "Cracked tooth syndrome. Part 1:aetiology and diagnosis", Br Dent J, 208, pp.459~463 (2010)
  4. Clark DJ, "Definitive diagnosis of early enamel and dentin cracks based on microscopic evaluation", J Esthet Restor Dent, 15, pp.391~401 (2003)
  5. Kim JH, "Association between longitudinal tooth fractures and visual detection methods in diagnosis", J Dent, 101, pp.103466~ (2020)
  6. Lee JI, "Evaluation of the clinical efficacy of quantitative light-induced fluorescence technology in diagnosing cracked teeth", Photodiagnosis Photodyn Ther, 41, pp.103299~ (2023)
  7. "Q-Ray User manual, Version 1.40, Ed", Inspektor Research Systems BV, Netherlands. Doc: 1730.01.19.01 Rev. 140, ~
  8. Jun MK, "Diagnosis and management of cracked tooth by quantitative light-induced fluorescence technology", Photodiagnosis Photodyn Ther, 26, pp.324~326 (2019)
  9. Son SA, "The effectiveness of a quantitative light-induced fluorescent device for the diagnosis of a cracked tooth: a case report", J Endod, 47, pp.1796~1800 (2021)
  10. Son SA, "Clinical applications of a quantitative light-induced fluorescent(QLF)device in the detection and management of cracked teeth : A case report", Photodiagnosis Photodyn Ther, 43, pp.103735~ (2023)
  11. Mamoun JS, "Cracked tooth diagnosis and treatment : An alternative paradigm", Eur J Dent, 9, pp.293~303 (2015)
  12. "치아 균열의 진단 및 치료에 관한 position statement", 대한치과보존학회 position statement, ~ (2016)