치과 진단용 방사선 발생장치의 검사 주기 평가
Evaluation of the Inspection Cycle of Dental Diagnostic X-ray Equipment
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
All diagnostic X-ray equipments in dental clinics must undergo a radiation safety inspection upon initial installation and every three years thereafter. The objective of this study was to propose an appropriate inspection cycle based on the results of safety management inspection for dental diagnostic X-ray equipment. The subject of this study was the radiation safety management inspection results of 774 X-ray equipments at 88 dental clinics. The period of use of the X-ray equipment was analyzed using the device type, inspection date, installation date, manufacturing date, approval date, date of discontinuation of use, transfer date, and disposal date. The X-ray equipment composition comprised 477 intraoral units, 143 panoramic units, 134 CBCT units, and 20 other radiographic units. In equipment suitability classification, out of 774 devices, 98.7% (764 devices) were deemed suitable, and 1.3% (10 devices) were deemed unsuitable. Among the 10 unfit devices, one (0.8%) had a lifespan of 9 years, two (1.8%) had 12 years, three (5.4%) had 15 years, one (4.3%) had 18 years, two (18.2%) had 21 years, and one (100%) had 27 years.
Abstract
All diagnostic X-ray equipments in dental clinics must undergo a radiation safety inspection upon initial installation and every three years thereafter. The objective of this study was to propose an appropriate inspection cycle based on the results of safety management inspection for dental diagnostic X-ray equipment. The subject of this study was the radiation safety management inspection results of 774 X-ray equipments at 88 dental clinics. The period of use of the X-ray equipment was analyzed using the device type, inspection date, installation date, manufacturing date, approval date, date of discontinuation of use, transfer date, and disposal date. The X-ray equipment composition comprised 477 intraoral units, 143 panoramic units, 134 CBCT units, and 20 other radiographic units. In equipment suitability classification, out of 774 devices, 98.7% (764 devices) were deemed suitable, and 1.3% (10 devices) were deemed unsuitable. Among the 10 unfit devices, one (0.8%) had a lifespan of 9 years, two (1.8%) had 12 years, three (5.4%) had 15 years, one (4.3%) had 18 years, two (18.2%) had 21 years, and one (100%) had 27 years.
참고문헌 (6)
- "의료법. 법률 제19421호, 2023년 11월 2020일 시행", ~
- "진단용 방사선 발생장치의 안전관리에 관한 규칙. 보건복지부령 제924호. 2022년 12월 19일 시행", ~
- 2022년도 의료기관 방사선관계종사자의 개인피폭선량 연보, , 질병관리청, ~
- 김현지, "2018년 진단용 방사선 안전관리 통계Status of Diagnostic X-ray Equipment in Korea, 2018", 주간 건강과 질병, 12(51), pp.2388~2396 (2019)
- 김현진, "2019년 진단용 방사선 안전관리 통계 Status of Diagnostic X-ray Equipment in Korea, 2019", 주간 건강과 질병, 13(16), pp.1006~1013 (2020)
- 송승기, "2021년 진단용 방사선 안전관리 통계 Status of Diagnostic X-ray Equipment in the Republic of Korea, 2021", 주간 건강과 질병, 15(51), pp.3021~3032 (2022)