본문 바로가기
KERD
논문KCI 등재

Differences in preoperative planning for high-tibial osteotomy between the standing and supine positions

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Previous studies have reported that alignment changes depend on the patient’s position in orthopedic surgery. However, it has not yet been well examined how the patient’s position affects the preoperative planning in high-tibial osteotomy (HTO). Therefore, the aim of this study was to investigate the effects of the patient’s position on preoperative planning in HTO.A total of 60 knees in 55 patients who underwent HTO were retrospectively examined. Virtual preoperative planning for medial open-wedge HTO (OWHTO), lateral closed-wedge HTO (CWHTO), and hybrid CWHTO were performed by setting the percentage of the weight-bearing line (%WBL) at 62% as an optimal alignment. The correction angle differences between the supine and standing radiographs were measured. The virtual %WBL (v%WBL) was determined by applying the correction angle obtained from the standing radiograph to the supine radiograph. The %WBL discrepancy (%WBLd) was calculated as v%WBL − 62 (%) to predict the possible correction errors during surgeries. A single regression analysis was performed to examine the correlation between the correction angle difference and %WBLd. The mean correction angle was significantly higher when the preoperative planning was based on standing radiographs than when based on supine radiographs ( P < 0.001), and the mean difference was 2.2 ± 1.5°. The difference between the two conditions in the medial opening gaps for OWHTO, lateral wedge sizes (mm) for CWHTO, and hybrid CWHTO were 2.6 ± 2.0, 2.3 ± 1.6, and 1.9 ± 1.4, respectively. The mean v%WBL was 71.2% ± 7.3%, and the mean %WBLd was 10.1% ± 7.4%. A single regression analysis revealed a linear correlation between the correction angle difference and %WBLd (%WBLd = 4.72 × correction angle difference + 0.08). No statistically significant difference in the parameters was found between the supine and standing radiographs postoperatively. We found significant differences in the estimated correction angles between the supine and standing radiographs in the planning for HTO. Therefore, surgeons should carefully consider the difference between supine and standing radiographs and estimate the possible correction error during surgery when planning a HTO.

Abstract

Previous studies have reported that alignment changes depend on the patient’s position in orthopedic surgery. However, it has not yet been well examined how the patient’s position affects the preoperative planning in high-tibial osteotomy (HTO). Therefore, the aim of this study was to investigate the effects of the patient’s position on preoperative planning in HTO.A total of 60 knees in 55 patients who underwent HTO were retrospectively examined. Virtual preoperative planning for medial open-wedge HTO (OWHTO), lateral closed-wedge HTO (CWHTO), and hybrid CWHTO were performed by setting the percentage of the weight-bearing line (%WBL) at 62% as an optimal alignment. The correction angle differences between the supine and standing radiographs were measured. The virtual %WBL (v%WBL) was determined by applying the correction angle obtained from the standing radiograph to the supine radiograph. The %WBL discrepancy (%WBLd) was calculated as v%WBL − 62 (%) to predict the possible correction errors during surgeries. A single regression analysis was performed to examine the correlation between the correction angle difference and %WBLd. The mean correction angle was significantly higher when the preoperative planning was based on standing radiographs than when based on supine radiographs ( P < 0.001), and the mean difference was 2.2 ± 1.5°. The difference between the two conditions in the medial opening gaps for OWHTO, lateral wedge sizes (mm) for CWHTO, and hybrid CWHTO were 2.6 ± 2.0, 2.3 ± 1.6, and 1.9 ± 1.4, respectively. The mean v%WBL was 71.2% ± 7.3%, and the mean %WBLd was 10.1% ± 7.4%. A single regression analysis revealed a linear correlation between the correction angle difference and %WBLd (%WBLd = 4.72 × correction angle difference + 0.08). No statistically significant difference in the parameters was found between the supine and standing radiographs postoperatively. We found significant differences in the estimated correction angles between the supine and standing radiographs in the planning for HTO. Therefore, surgeons should carefully consider the difference between supine and standing radiographs and estimate the possible correction error during surgery when planning a HTO.

참고문헌 (32)

  1. Fujisawa Y, "The effect of high tibial osteotomy on osteoarthritis of the knee. An arthroscopic study of 54 knee joints", Orthop Clin North Am, 10(3), pp.585~608 (1979)
  2. Coventry MB, "Proximal tibial osteotomy. A critical long-term study of eighty-seven cases", J Bone Joint Surg Am, 75(2), pp.196~201 (1993)
  3. Yasuda K, "A ten-to 15-year follow-up observation of high tibial osteotomy in medial compartment osteoarthrosis", Clin Orthop Relat Res, 282, pp.186~195 (1992)
  4. Hernigou P, "Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study", J Bone Joint Surg Am, 69(3), pp.332~354 (1987)
  5. Sprenger TR, "Tibial osteotomy for the treatment of varus gonarthrosis. Survival and failure analysis to twenty-two years", J Bone Joint Surg Am, 85(3), pp.469~474 (2003)
  6. Kim KI, "Change of chondral lesions and predictive factors after medial open-wedge high tibial osteotomy with a locked plate system", Am J Sports Med, 45(7), pp.1615~1621 (2017)
  7. Hantes ME, "Satisfactory functional and radiological outcomes can be expected in young patients under 45 years old after open wedge high tibial osteotomy in a long-term follow-up", Knee Surg Sports Traumatol Arthrosc, 26(11), pp.3199~3205 (2018)
  8. Hidetomo Saito, "Short-Term Results of Hybrid Closed-Wedge High Tibial Osteotomy: A Case Series with a Minimum 3-Year Follow-up", Knee Surgery and Related Research, 30(4), pp.293~302 (2018), 대한슬관절학회
  9. Miniaci A, "Proximal tibial osteotomy. A new fixation device", Clin Orthop Relat Res, 246, pp.250~259 (1989)
  10. Dugdale TW, "Preoperative planning for high tibial osteotomy. The effect of lateral tibiofemoral separation and tibiofemoral length", Clin Orthop Relat Res, 274, pp.248~264 (1992)
  11. Coventry MB, "Upper tibial osteotomy for osteoarthritis", J Bone Joint Surg Am, 67(7), pp.1136~1140 (1985)
  12. Seong-Dae Yoon, "Comparison of Cable Method and Miniaci Method Using Picture Archiving and Communication System in Preoperative Planning for Open Wedge High Tibial Osteotomy", Knee Surgery and Related Research, 28(4), pp.283~288 (2016), 대한슬관절학회
  13. Kim HJ, "Preoperative planning using the picture archiving and communication system technique in high tibial osteotomy", J Orthop Surg(Hong Kong), 25(1) (2017)[DOI]
  14. Schroter S, "Digital planning of high tibial osteotomy. Interrater reliability by using two different software", Knee Surg Sports Traumatol Arthrosc, 21(1), pp.189~196 (2013)
  15. Kim HJ, "More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy", Knee Surg Sports Traumatol Arthrosc, 26(11), pp.3452~3458 (2018)
  16. Kuriyama S, "Clinical efficacy of preoperative 3D planning for reducing surgical errors during open-wedge high tibial osteotomy", J Orthop Res, 37(4), pp.898~907 (2019)
  17. Chernchujit B, "Preoperative planning of medial opening wedge high tibial osteotomy using 3D computer-aided design weight-bearing simulated guidance : technique and preliminary result", J Orthop Surg(Hong Kong), 27(1) (2019)
  18. Ogawa H, "Preoperative varus laxity correlates with overcorrection in medial opening wedge high tibial osteotomy", Arch Orthop Trauma Surg, 136(10), pp.1337~1342 (2016)
  19. Lee DH, "Effect of soft tissue laxity of the knee joint on limb alignment correction in open-wedge high tibial osteotomy", Knee Surg Sports Traumatol Arthrosc, 24(12), pp.3704~3712 (2016)
  20. Park JG, "Increased preoperative medial and lateral laxity is a predictor of overcorrection in open wedge high tibial osteotomy", Knee Surg Sports Traumatol Arthrosc, 28(10), pp.3164~3172 (2020)
  21. Deep K, "The dynamic nature of alignment and variations in normal knees", Bone Joint J, 97-B(4), pp.498~502 (2015)
  22. Sabharwal S, "Assessment of lower limb alignment : supine fluoroscopy compared with a standing full-length radiograph", J Bone Joint Surg Am, 90(1), pp.43~51 (2008)
  23. Wang JH, "Discrepancy of alignment in different weight bearing conditions before and after high tibial osteotomy", Int Orthop, 41(1), pp.85~92 (2017)
  24. Ogata K, "Standing radiographs cannot determine the correction in high tibial osteotomy", J Bone Joint Surg Br, 73(6), pp.927~931 (1991)
  25. Brittberg M, "Evaluation of cartilage injuries and repair", J Bone Joint Surg Am, 85-A(Suppl 2), pp.58~69 (2003)
  26. Takeuchi R, "A novel closed-wedge high tibial osteotomy procedure to treat osteoarthritis of the knee : hybrid technique and rehabilitation measures", Arthrosc Tech, 3(4), pp.e431~e437 (2014)
  27. So SY, "Difference in joint line convergence angle between the supine and standing positions is the most important predictive factor of coronal correction error after medial opening wedge high tibial osteotomy", Knee Surg Sports Traumatol Arthrosc, 28(5), pp.1516~1525 (2020)
  28. Akasaki Y, "Patient-specific prediction of joint line convergence angle after high tibial osteotomy using a whole-leg radiograph standing on lateral-wedge insole", Knee Surg Sports Traumatol Arthrosc, 28(10), pp.3200~3206 (2020)
  29. Lee DK, "Preoperative latent medial laxity and correction angle are crucial factors for overcorrection in medial open-wedge high tibial osteotomy", Knee Surg Sports Traumatol Arthrosc, 28(5), pp.1411~1418 (2020)
  30. Kim MS, "Intraoperative adjustment of alignment under valgus stress reduces outliers in patients undergoing medial opening-wedge high tibial osteotomy", Arch Orthop Trauma Surg, 137(8), pp.1035~1045 (2017)
  31. Shin KH, "Preoperative supine radiographs are more accurate than standing radiographs for preoperative planning in medial open-wedge high tibial osteotomy", Arthroscopy, 36(6), pp.1655~1664 (2020)
  32. Jang KM, "Intraoperative fluoroscopic assessment of limb alignment is a reliable predictor for postoperative limb alignment in biplanar medial opening-wedge high tibial osteotomy", J Arthroplast, 32(3), pp.756~760 (2017)

이 간행물의 다른 논문 (46건)