본문 바로가기
KERD
논문KCI 등재

안면 비대칭 환자의 하악골 수술 후 하악골 변화에 대한 3차원 CT 영상 비교

Comparision of Mandible Changes on Three-Dimensional Computed Tomography image After Mandibular Surgery in Facial Asymmetry Patients

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류의학일반

초록

Background:When surgeons plan mandible ortho surgery for patients with skeletal class III facial asymmetry, they must be consider the exact method of surgery for correction of the facial asymmetry. Three-dimensional (3D) CT imaging is efficient in depicting specific structures in the craniofacial area. It reproduces actual measurements by minimizing errors from patient movement and allows for image magnification. Due to the rapid development of digital image technology and the expansion of treatment range, rapid progress has been made in the study of three-dimensional facial skeleton analysis. The purpose of this study was to conduct 3D CT image comparisons of mandible changes after mandibular surgery in facial asymmetry patients. Materials & methods:This study included 7 patients who underwent 3D CT before and after correction of facial asymmetry in the oral and maxillofacial surgery department of Yeungnam University Hospital between August 2002 and November 2005. Patients included 2 males and 5 females, with ages ranging from 16 years to 30 years (average 21.4 years). Frontal CT images were obtained before and after surgery, and changes in mandible angle and length were measured. Results:When we compared the measurements obtained before and after mandibular surgery in facial asymmetry patients, correction of facial asymmetry was identified on the “after” images. The mean difference between the right and left mandibular angles before mandibular surgery was 7°, whereas after mandibular surgery it was 1.5°. The right and left mandibular length ratios subtracted from 1 was 0.114 before mandibular surgery, while it was 0.036 after mandibular surgery. The differences were analyzed using the nonparametric test and the Wilcoxon signed ranks test (p<0.05). Conclusion:The system that has been developed produces an accurate three-dimensional representation of the skull, upon which individualized surgery of the skull and jaws is easily performed. The system also permits accurate measurement and monitoring of postsurgical changes to the face and jaws through reproducible and noninvasive means.

Abstract

Background:When surgeons plan mandible ortho surgery for patients with skeletal class III facial asymmetry, they must be consider the exact method of surgery for correction of the facial asymmetry. Three-dimensional (3D) CT imaging is efficient in depicting specific structures in the craniofacial area. It reproduces actual measurements by minimizing errors from patient movement and allows for image magnification. Due to the rapid development of digital image technology and the expansion of treatment range, rapid progress has been made in the study of three-dimensional facial skeleton analysis. The purpose of this study was to conduct 3D CT image comparisons of mandible changes after mandibular surgery in facial asymmetry patients. Materials & methods:This study included 7 patients who underwent 3D CT before and after correction of facial asymmetry in the oral and maxillofacial surgery department of Yeungnam University Hospital between August 2002 and November 2005. Patients included 2 males and 5 females, with ages ranging from 16 years to 30 years (average 21.4 years). Frontal CT images were obtained before and after surgery, and changes in mandible angle and length were measured. Results:When we compared the measurements obtained before and after mandibular surgery in facial asymmetry patients, correction of facial asymmetry was identified on the “after” images. The mean difference between the right and left mandibular angles before mandibular surgery was 7°, whereas after mandibular surgery it was 1.5°. The right and left mandibular length ratios subtracted from 1 was 0.114 before mandibular surgery, while it was 0.036 after mandibular surgery. The differences were analyzed using the nonparametric test and the Wilcoxon signed ranks test (p<0.05). Conclusion:The system that has been developed produces an accurate three-dimensional representation of the skull, upon which individualized surgery of the skull and jaws is easily performed. The system also permits accurate measurement and monitoring of postsurgical changes to the face and jaws through reproducible and noninvasive means.

참고문헌 (18)

  1. Broadbent BH, "A new x-ray technique and its application to orthodontia", Angle Orthod, 1(2), pp.45~66 (1931)
  2. Hatcher DC, "Science and Practice of Occlusion", pp.349~364 (1997), Quintessence Publishing
  3. Vig PS, "Current Controversies in Orthodontics", pp.269~310 (1991), Quintessence Publishing
  4. Wylie W.H., "Understated vertical projections of the head from lateral and posteroanterior roentogenograms", Am J Roentenol, 60(3), pp.414~ (1948)
  5. Vogel CJ, "Correction of frontal dimensions from head x-rays", Angle Orthod, 37(1), pp.1~8 (1967)
  6. Grayson BH, "Analysis of craniofacial asymmetry by multiplane cephalometry", Am J Orthod, 84(3), pp.217~224 (1983)
  7. Brown T, "Computer assisted location of reference points in three dimensions for radiographic cephalometry", Am J Orthod Dentofacial Orthop, 95(6), pp.490~498 (1989)
  8. Darling CF, "Three dimensional computed tomography imaging in the evaluation of craniofacial abnormality", J Natl Med Assoc, 86(9), pp.676~680 (1994)
  9. Grumone DC. Kappeyne van de Coppello MA, "A Frontal asymmetry analysis", J Clin Orthod, 21(7), pp.448~465 (1987)
  10. Peck S, "Skeletal asymmetry in esthetically pleasing faces", Angle Orthod, 61(1), pp.43~47 (1991)
  11. Severt TR, "Postsurgical stability following correction of severe facial asymmetry", Int J Adult Orthod Orthognath Surg, 12(4), pp.251~261 (1997)
  12. Meredith G., "Facial photography for the orthodontic office", Am J Orthod Dentofacial Orthop, d11(5) (1997)
  13. Dahan J., "A simple digital procedure to assess facial asymmetry", Am J Orthod Dentofacial Orthop, 122(1), pp.110~116 (2002)
  14. Edler R, "Outcome measurement in the correction of mandibular asymmetry", Am J Orthod Dentofacial Orthop, 125, pp.435~443 (2004)
  15. Richtsmeier JT, "Precision, repeatability, and validation of the localization of cranial landmarks using computed tomography scans", Cleft Palate Craniofac J, 32(3), pp.217~227 (1995)
  16. Williams FL, "Comparison of mandibular landmarks from computed tomography and 3D digitizer data", Clin Anat, 16(6), pp.494~500 (2003)
  17. Cavalcanti MG, "Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications", Dentomaxillofac Radiol, 33(3), pp.170~176 (2004)
  18. Kragskov J, "A comparison of three-dimensional computed tomography scans and stereolithographic models for evaluation of craniofacial anomalies", J Oral Maxillofac Surg, 54(4), pp.402~411 (1996)

관련 논문AI추천

이 간행물의 다른 논문 (16건)