본문 바로가기
KERD
논문KCI 등재

한국 성인에서의 Neuro OneⓇ System을 이용한 인공와우이식의 단기 임상결과

Short-Term Clinical Outcome of Neuro OneⓇ System Cochlear Implantation in Korean Adults

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류이비인후과학

초록

Background and Objectives This study analyzed short-term clinical outcome and safetyof Neuro OneⓇ (Oticon Medical) cochlear implantation on postlingually deafened Koreanadults. Subjects and Method A prospective study was performed on five postlingually deafenedKorean adults who underwent Neuro OneⓇ cochlear implantation between April and June,2016. All cases were successfully implanted via round window approach. Preoperative puretone audiometry and speech perception score [phonetically balanced (PB) words, bi-syllablewords, Korean version-central institute for the deaf (K-CID)], intraoperative evoked compoundaction potential (ECAP), postoperative audiometry, aided warble-tone thresholds and speechperception scores after 6 months were evaluated. Residual hearing group was defined as patientswith below 40 dB of average audiometric threshold in low frequency (250 and 500 Hz). Preservation of residual hearing and postoperative complication were also evaluated. Results The mean age of five patients (3 men, 2 women) was 37.6 years. All of the recipientswere unsatisfied about the conventional hearing aid. Two patients met the criteria for belongingto a residual hearing group. The audiometric threshold on the implanted side was 102.8dB, and the opposite side was 89.6 dB. The speech perception score with hearing aid resultedin the PB word score of 35.5%, bi-syllable word score of 50%, and the open set sentence testof 62.5% on the average. The mean operation time was 87 minutes. Three patients showednormal ECAP response throughout the entire electrode intraoperatively, but the other two patientscould not detect ECAP response intraoperatively. However, we could eventually identifyECAP responses in all cases postoperatively. All patients of residual hearing group could preservetheir residual hearing without deteriorating more than 10 dB on audiometry. At 6months after implantation, there was significant improvement of speech perception scores (PBword score was 54.1%; bi-syllable word score was 68.1% and K-CID was 86.2%). Conclusion Neuro OneⓇ cochlear implant system was able to preserve residual hearing withrelative short operation time. Short-term clinical outcome showed no significant differencewith other cochlear implant devices. However, intraoperative ECAP measurement was notconsistent. Further investigation was necessary.

Abstract

Background and Objectives This study analyzed short-term clinical outcome and safetyof Neuro OneⓇ (Oticon Medical) cochlear implantation on postlingually deafened Koreanadults. Subjects and Method A prospective study was performed on five postlingually deafenedKorean adults who underwent Neuro OneⓇ cochlear implantation between April and June,2016. All cases were successfully implanted via round window approach. Preoperative puretone audiometry and speech perception score [phonetically balanced (PB) words, bi-syllablewords, Korean version-central institute for the deaf (K-CID)], intraoperative evoked compoundaction potential (ECAP), postoperative audiometry, aided warble-tone thresholds and speechperception scores after 6 months were evaluated. Residual hearing group was defined as patientswith below 40 dB of average audiometric threshold in low frequency (250 and 500 Hz). Preservation of residual hearing and postoperative complication were also evaluated. Results The mean age of five patients (3 men, 2 women) was 37.6 years. All of the recipientswere unsatisfied about the conventional hearing aid. Two patients met the criteria for belongingto a residual hearing group. The audiometric threshold on the implanted side was 102.8dB, and the opposite side was 89.6 dB. The speech perception score with hearing aid resultedin the PB word score of 35.5%, bi-syllable word score of 50%, and the open set sentence testof 62.5% on the average. The mean operation time was 87 minutes. Three patients showednormal ECAP response throughout the entire electrode intraoperatively, but the other two patientscould not detect ECAP response intraoperatively. However, we could eventually identifyECAP responses in all cases postoperatively. All patients of residual hearing group could preservetheir residual hearing without deteriorating more than 10 dB on audiometry. At 6months after implantation, there was significant improvement of speech perception scores (PBword score was 54.1%; bi-syllable word score was 68.1% and K-CID was 86.2%). Conclusion Neuro OneⓇ cochlear implant system was able to preserve residual hearing withrelative short operation time. Short-term clinical outcome showed no significant differencewith other cochlear implant devices. However, intraoperative ECAP measurement was notconsistent. Further investigation was necessary.

참고문헌 (9)

  1. Semenov YR, "Cochlear implants: clinical and societal outcomes", Otolaryngol Clin North Am, 45(5), pp.959~981 (2012)[DOI]
  2. Gaylor JM, "Cochlear implantation in adults: a systematic review and meta-analysis", JAMA Otolaryngol Head Neck Surg, 139(3), pp.265~272 (2013)[DOI]
  3. Geleoc GS, "Sound strategies for hearing restoration", Science, 344(6184), pp.1241062~ (2014)[DOI]
  4. Di Lella F, "Main peak interleaved sampling (MPIS) strategy: effect of stimulation rate variations on speech perception in adult cochlear implant recipients using the Digisonic SP cochlear implant", Acta Otolaryngol, 130(1), pp.102~107 (2010)[DOI]
  5. Shannon RV, "Advances in auditory prostheses", Curr Opin Neurol, 25(1), pp.61~66 (2012)[DOI]
  6. Svirsky MA, "Language development in profoundly deaf children with cochlear implants", Psychol Sci, 11(2), pp.153~158 (2000)[DOI]
  7. Bento RF, "Residual Hearing Preservation with the Evo(R) Cochlear Implant Electrode Array: Preliminary Results", Int Arch Otorhinolaryngol, 20(4), pp.353~358 (2016)[DOI]
  8. Han JJ, "Prognostic value of psychological state in cochlear implantation", Acta Otolaryngol, 136(2), pp.154~158 (2016)[DOI]
  9. Moon IJ, "The influence of various factors on the performance of repetition tests in adults with cochlear implants", Eur Arch Otorhinolaryngol, 269(3), pp.739~745 (2012)[DOI]

관련 논문AI추천

와우축을 감싸는 가는 전극을 가진 CI532 기기를 이용한 인공와우 수술의 단기 경험: 기존의 기기와의 비교강우석, 곽민영, 김예리, 박진택, 박홍주, 안중호, 이지연, 정종우대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2021 · 제64권 제4호노인 언어습득 후 고도난청 환자의 인공와우이식 후 말 지각 능력 변화김춘동, 사대진, 최전하대한이비인후과학회 부산,울산,경남 지부회 · 임상이비인후과2015 · 제26권 제1호노인 난청 환자에서의 와우이식술의 결과 분석김영호, 김종선, 김형미, 박민현, 서명환, 오승하, 이준호, 장선오, 장정훈대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2008 · 제51권 제6호인공와우 환자에서의 대뇌피질청각유발전위의 측정: 예비 연구문현, 남수정, 박홍주, 양찬주, 이지연, 이환서, 임원섭대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2016 · 제59권 제6호수술 후 발생한 일측성 난청에서 OsiaⓇ2 골전도 임플란트를 이용한 청각재활문서진, 문인석대한이비인후과학회 · 대한이비인후과학회지 두경부외과학2023 · 제66권 제2호개방형 유양동을 가진 환자에서의 인공와우 이식술김춘동, 백훈희, 조현상, 최전하대한이비인후과학회 부산,울산,경남 지부회 · 임상이비인후과2016 · 제27권 제1호