Background: Maintaining the quality of cryopreserved cord blood is crucial. In this pilot study, we describe the results of the internal quality control program for a cord blood bank thus far. Methods: Donated cord blood units unsuitable for transplantation were selected for internal quality control once a month. One unit of cord blood, aliquoted into 21 capillaries, was cryopreserved and thawed annually to analyze the total nucleated cell count, CD34+ cell count, cell viability test, and colony-forming units assay. Results: No significant differences in the variables (total nucleated cell count, cell viability, CD34+ cell count) were observed between samples cryopreserved for one and two years. Upon comparing the variables before cryopreservation and post thawing with the capillaries of one year of storage, cell viability and CD34+ cell counts decreased significantly. The use of cord blood samples in capillaries, which can be easily stored for a long period, was similar to the methods used for testing segments attached to the cord blood unit. Conclusions: The results of this study may be useful for determining the period during which the quality of cryopreserved cord blood units used for transplantation is maintained.

Abstract

Background: Maintaining the quality of cryopreserved cord blood is crucial. In this pilot study, we describe the results of the internal quality control program for a cord blood bank thus far. Methods: Donated cord blood units unsuitable for transplantation were selected for internal quality control once a month. One unit of cord blood, aliquoted into 21 capillaries, was cryopreserved and thawed annually to analyze the total nucleated cell count, CD34+ cell count, cell viability test, and colony-forming units assay. Results: No significant differences in the variables (total nucleated cell count, cell viability, CD34+ cell count) were observed between samples cryopreserved for one and two years. Upon comparing the variables before cryopreservation and post thawing with the capillaries of one year of storage, cell viability and CD34+ cell counts decreased significantly. The use of cord blood samples in capillaries, which can be easily stored for a long period, was similar to the methods used for testing segments attached to the cord blood unit. Conclusions: The results of this study may be useful for determining the period during which the quality of cryopreserved cord blood units used for transplantation is maintained.

참고문헌 (14)

  1. Gluckman E, "Hematopoietic reconstitution in a patient with Fanconi’s anemia by means of umbilical-cord blood from an HLA-identical sibling", N Engl J Med, 321, pp.1174~1178 (1989)
  2. 이혜련, "Quality of cord blood cryopreserved for up to 5 years", Blood Research, 49(1), pp.54~60 (2014), 대한혈액학회
  3. Lee HR, "Increased numbers of total nucleated and CD34+ cells in blood group O cord blood: an analysis of neonatal innate factors in the Korean population", Transfusion, 52, pp.76~81 (2012)
  4. Lee HR, "Attached segment has higher CD34+ cells and CFU-GM than the main bag after thawing", Cell Transplant, 24, pp.305~310 (2015)
  5. "Safety, Management, etc. of Human Tissue Act"[URL]
  6. Wagner JE, "Transplantation of unrelated donor umbilical cord blood in 102 patients with malignant and nonmalignant diseases: influence of CD34 cell dose and HLA disparity on treatment-related mortality and survival", Blood, 100, pp.1611~1618 (2002)
  7. Prasad VK, "Unrelated donor umbilical cord blood transplantation for inherited metabolic disorders in 159 pediatric patients from a single center: influence of cellular composition of the graft on transplantation outcomes", Blood, 112, pp.2979~2989 (2008)
  8. Page KM, "The Cord Blood Apgar: a novel scoring system to optimize selection of banked cord blood grafts for transplantation (CME)", Transfusion, 52, pp.272~283 (2012)
  9. Broxmeyer HE, "Hematopoietic stem", progenitor cells, generation of induced pluripotent stem cells, and isolation of endothelial progenitors from 21- to 23.5-year cryopreserved cord blood, 2011, pp.117, 4773~4777
  10. Broxmeyer HE, "High-efficiency recovery of functional hematopoietic progenitor and stem cells from human cord blood cryopreserved for 15 years", Proc Natl Acad Sci U S A, 100, pp.645~650 (2003)
  11. Fernyhough LJ, "Relative recovery of haematopoietic stem cell products after cryogenic storage of up to 19 years", Bone Marrow Transplant, 48, pp.32~35 (2013)
  12. Hubel A, "Postthaw characterization of umbilical cord blood: markers of storage lesion", Transfusion, 55, pp.1033~1039 (2015)
  13. Laroche V, "Cell loss and recovery in umbilical cord blood processing: a comparison of postthaw and postwash samples", Transfusion, 45, pp.1909~1916 (2005)
  14. Flores AI, "Consistency of the initial cell acquisition procedure is critical to the standardization of CD34+ cell enumeration by flow cytometry: results of a pairwise analysis of umbilical cord blood units and cryopreserved aliquots", Transfusion, 49, pp.636~647 (2009)

관련 논문AI추천

이 간행물의 다른 논문 (16건)