초록
PURPOSE. The purpose of this study was to assess the difference in efficacy between calcium metaphosphate (CMP)-coated implant fixtures and conventional resorbable blasted media (RBM) processed implant fixtures. MATERIALS AND METHODS. This study targeted 50 implants from 44 patients who visited Dankook University Dental Hospital. Implantations were done separately for RBM treated and CMP-coated implants, although their design was the same. Calcium metaphosphate has a quicker biodegradation process through hydrolysis compared to other phosphate calcium groups. For the first year of the implantation, the resorption volume of marginal bone analyzed via radiography and perio-test value were measured, under the check plan. Their analyses were composed of a non-inferiority trials test. A 95% level of reliability was used. RESULTS. In the comparative analysis of the resorption volume of marginal bone and the perio-test value, no statistically significant difference was found between the CMP-coated implants and RBM implants. CONCLUSION. One year after the implant placement, CMP-coated implants were found not to be inferior to the conventional RBM implants.
Abstract
PURPOSE. The purpose of this study was to assess the difference in efficacy between calcium metaphosphate (CMP)-coated implant fixtures and conventional resorbable blasted media (RBM) processed implant fixtures. MATERIALS AND METHODS. This study targeted 50 implants from 44 patients who visited Dankook University Dental Hospital. Implantations were done separately for RBM treated and CMP-coated implants, although their design was the same. Calcium metaphosphate has a quicker biodegradation process through hydrolysis compared to other phosphate calcium groups. For the first year of the implantation, the resorption volume of marginal bone analyzed via radiography and perio-test value were measured, under the check plan. Their analyses were composed of a non-inferiority trials test. A 95% level of reliability was used. RESULTS. In the comparative analysis of the resorption volume of marginal bone and the perio-test value, no statistically significant difference was found between the CMP-coated implants and RBM implants. CONCLUSION. One year after the implant placement, CMP-coated implants were found not to be inferior to the conventional RBM implants.
참고문헌 (31)
- Albrektsson T, "State of the art in oral implants", J Clin Periodontol, 18, pp.474~481 (1991)
- Eckert SE, "Validation of dental implant systems through a review of literature supplied by system manufacturers", J Prosthet Dent, 77, pp.271~279 (1997)
- Albrektsson T, "Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man", Acta Orthop Scand, 52, pp.155~170 (1981)
- Carlsson L, "Removal torques for polished and rough titanium implants", Int J Oral Maxillofac Implants, 3, pp.21~24 (1988)
- 신화섭, "표면 처리 방법에 따른 타이타늄의 미세 표면 거칠기, 표면 젖음성, fibronectin 흡착량에 미치는 영향", 대한치과보철학회지, 44(4), pp.443~454 (2006), 대한치과보철학회
- Chen J, "Effect of atmosphere on phase transformation in plasma-sprayed hydroxyapatite coatings during heat treatment", J Biomed Mater Res, 34, pp.15~20 (1997)
- Block MS, "Evaluation of hydroxylapatitecoated titanium dental implants in dogs", J Oral Maxillofac Surg, 45, pp.601~607 (1987)
- Darimont GL, "In vivo behaviour of hydroxyapatite coatings on titanium implants: a quantitative study in the rabbit", Biomaterials, 23, pp.2569~2575 (2002)
- Yamashita K, "Materials Science Monographs: Inorganic phosphate materials", pp.221~246 (1989), Elsevier
- Lee YM, "Tissueengineered growth of bone by marrow cell transplantation using porous calcium metaphosphate matrices", J Biomed Mater Res, 54, pp.216~223 (2001)
- Park EK, "Cellular biocompatibility and stimulatory effects of calcium metaphosphate on osteoblastic differentiation of human bone marrow-derived stromal cells", Biomaterials, 25, pp.3403~3411 (2004)
- Changkook You, "Characterization and in vivo evaluation of calcium phosphatecoated cp-titanium by dip-spin method", Current Applied Physics, 5(5), pp.501~506 (2005), 한국물리학회
- Yeo IS, "Biomechanical and histomorphometric study of dental implants with different surface characteristics", J Biomed Mater Res B Appl Biomater, 87, pp.303~311 (2008)
- The Korean academy of oral and maxillofa, "Atlas of implant terminology", pp.15~16 (2003), Deahan Publishing
- Kim YK, "Implant problem solution. Vol 2: Surgery and Prosthetic problem solution", pp.9~10 (2003), Deahan Publishing
- Roos J, "A qualitative and quantitative method for evaluating implant success: a 5-year retrospective analysis of the Brånemark implant", Int J Oral Maxillofac Implants, 12, pp.504~514 (1997)
- Buser D, "Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants", Clin Oral Implants Res, 1, pp.33~40 (1990)
- Buser D, "Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants", Clin Oral Implants Res, 8, pp.161~172 (1997)
- Albrektsson T, "The long-term efficacy of currently used dental implants: a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
- Buser D, "Regeneration and enlargement of jaw bone using guided tissue regeneration", Clin Oral Implants Res, 1, pp.22~32 (1990)
- Noack N, "Long-term results after placement of dental implants: longitudinal study of 1,964 implants over 16 years", Int J Oral Maxillofac Implants, 14, pp.748~755 (1999)
- Roos J, "A qualitative and quantitative method for evaluating implant success: a 5-year retrospective analysis of the Brånemark implant", Int J Oral Maxillofac Implants, 12, pp.504~514 (1997)
- Brånemark PI, "Tissue-integrated prostheses: Osseointegration in clinical dentistry, In Patient selection", pp.199~209 (1985), Quintessence
- Sekine H, "Mobility characteristics and tactile sensitivity of osseointegrated fixturesupporting systems, InTissue intergration in oral maxillofacial reconstruction", pp.236~332 (1986), Elsevier
- Mombelli A, "The microbiota associated with successful or failing osseointegrated titanium implants", Oral Microbiol Immunol, 2, pp.145~151 (1987)
- Curtis DA, "Occlusal considerations for implant restorations in the partially edentulous patient", J Calif Dent Assoc, 28, pp.771~779 (2000)
- Weinberg LA, "Reduction of implant loading with therapeutic biomechanics", Implant Dent, 7, pp.277~285 (1998)
- Schulte W, "Periotest for measuring periodontal characteristics--correlation with periodontal bone loss", J Periodontal Res, 27, pp.184~190 (1992)
- Faulkner MG, "The use and abuse of the Periotest for 2-piece implant", abutment systems, 2001, pp.16, 486~494
- Wyatt CC, "Bone level changes proximal to oral implants supporting fixed partial prostheses", Clin Oral Implants Res, 13, pp.162~168 (2002)
- Schwartz-Arad D, "A radiographic evaluation of cervical bone loss associated with immediate and delayed implants placed for fixed restorations in edentulous jaws", J Periodontol, 75, pp.652~657 (2004)