PURPOSE. The storage conditions of impressions affect the dimensional accuracy of the impression materials. The aim of the study was to assess the effects of storage time on dimensional accuracy of five different impression materials by cone beam computed tomography (CBCT). MATERIALS AND METHODS. Polyether (Impregum), hydrocolloid (Hydrogum and Alginoplast), and silicone (Zetaflow and Honigum) impression materials were used for impressions taken from an acrylic master model. The impressions were poured and subjected to four different storage times: immediate use, and 1, 3, and 5 days of storage. Line 1 (between right and left first molar mesiobuccal cusp tips) and Line 2 (between right and left canine tips) were measured on a CBCT scanned model, and time dependent mean differences were analyzed by two-way univariate and Duncan’s test (α=.05). RESULTS. For Line 1, the total mean difference of Impregum and Hydrogum were statistically different from Alginoplast (P<.05), while Zetaflow and Honigum had smaller discrepancies. Alginoplast resulted in more difference than the other impressions (P<.05). For Line 2, the total mean difference of Impregum was statistically different from the other impressions. Significant differences were observed in Line 1 and Line 2 for the different storage periods (P<.05). CONCLUSION. The dimensional accuracy of impression material is clinically acceptable if the impression material is stored in suitable conditions.

Abstract

PURPOSE. The storage conditions of impressions affect the dimensional accuracy of the impression materials. The aim of the study was to assess the effects of storage time on dimensional accuracy of five different impression materials by cone beam computed tomography (CBCT). MATERIALS AND METHODS. Polyether (Impregum), hydrocolloid (Hydrogum and Alginoplast), and silicone (Zetaflow and Honigum) impression materials were used for impressions taken from an acrylic master model. The impressions were poured and subjected to four different storage times: immediate use, and 1, 3, and 5 days of storage. Line 1 (between right and left first molar mesiobuccal cusp tips) and Line 2 (between right and left canine tips) were measured on a CBCT scanned model, and time dependent mean differences were analyzed by two-way univariate and Duncan’s test (α=.05). RESULTS. For Line 1, the total mean difference of Impregum and Hydrogum were statistically different from Alginoplast (P<.05), while Zetaflow and Honigum had smaller discrepancies. Alginoplast resulted in more difference than the other impressions (P<.05). For Line 2, the total mean difference of Impregum was statistically different from the other impressions. Significant differences were observed in Line 1 and Line 2 for the different storage periods (P<.05). CONCLUSION. The dimensional accuracy of impression material is clinically acceptable if the impression material is stored in suitable conditions.

참고문헌 (29)

  1. Johnson GH, "Restorative dental materials", pp.348~368 (2001), Elsevier
  2. Nicholls JI, "The measurement of distortion: theoretical considerations", J Prosthet Dent, 37, pp.578~586 (1977)
  3. Hamalian TA, "Impression materials in fixed prosthodontics: influence of choice on clinical procedure", J Prosthodont, 20, pp.153~160 (2011)
  4. Linke BA, "Distortion analysis of stone casts made from impression materials", J Prosthet Dent, 54, pp.794~802 (1985)
  5. Brosky ME, "Evaluation of dental arch reproduction using three-dimensional optical digitization", J Prosthet Dent, 90, pp.434~440 (2003)
  6. Sohmura T, "Use of an ultrahigh-speed laser scanner for constructing three-dimensional shapes of dentition and occlusion", J Prosthet Dent, 84, pp.345~352 (2000)
  7. Tarawneh FM, "Three-dimensional assessment of dental casts’ occlusal surfaces using two impression materials", J Oral Rehabil, 35, pp.821~826 (2008)
  8. Tomassetti JJ, "A comparison of 3 computerized Bolton tooth-size analyses with a commonly used method", Angle Orthod, 71, pp.351~357 (2001)
  9. Elefteriadis JN, "Evaluation of impacted canines by means of computerized tomography", Int J Adult Orthodon Orthognath Surg, 11, pp.257~264 (1996)
  10. Phillips RW, "Properties of alginates", J Am Dent Assoc, 43, pp.1~17 (1951)
  11. Coleman RM, "Dimensional stability of irreversible hydrocolloid impression material", Am J Orthod, 75, pp.438~446 (1979)
  12. Anseth KS, "Mechanical properties of hydrogels and their experimental determination", Biomaterials, 17, pp.1647~1657 (1996)
  13. Dalstra M, "From alginate impressions to digital virtual models: accuracy and reproducibility", J Orthod, 36, pp.36~41 (2009)
  14. Alcan T, "The relationship between digital model accuracy and time-dependent deformation of alginate impressions", Angle Orthod, 79, pp.30~36 (2009)
  15. Sedda M, "Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids", J Contemp Dent Pract, 9, pp.59~66 (2008)
  16. Henry PJ, "Dimensional stability and accuracy of rubber impression materials", Aust Dent J, 19, pp.162~166 (1974)
  17. Shellhart WC, "Reliability of the Bolton tooth-size analysis when applied to crowded dentitions", Angle Orthod, 65, pp.327~334 (1995)
  18. Champagne M, "Reliability of measurements from photocopies of study models", J Clin Orthod, 26, pp.648~650 (1992)
  19. Lowey MN, "The development of a new method of cephalometric and study cast mensuration with a computer controlled, video image capture system. Part II: Study cast mensuration", Br J Orthod, 20, pp.315~331 (1993)
  20. Rossouw PE, "A critical comparison of three methods for measuring dental models", J Dent Assoc S Afr, 46, pp.223~226 (1991)
  21. Quick DC, "Use of a scanning laser three-dimensional digitizer to evaluate dimensional accuracy of dental impression materials", J Prosthet Dent, 68, pp.229~235 (1992)
  22. Yamamoto K, "Optical measurement of dental cast profile and application to analysis of three-dimensional tooth movement in orthodontics", Front Med Biol Eng, 1, pp.119~130 (1989)
  23. Santoro M, "Comparison of measurements made on digital and plaster models", Am J Orthod Dentofacial Orthop, 124, pp.101~105 (2003)
  24. Zilberman O, "Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual orthodontic models", Angle Orthod, 73, pp.301~306 (2003)
  25. Veenema AC, "Index of Complexity, Outcome and Need scored on plaster and digital models", Eur J Orthod, 31, pp.281~286 (2009)
  26. Bootvong K, "Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity", Eur J Orthod, 32, pp.589~595 (2010)
  27. Yan B, "Development and study of three-dimensional CT scanning system for dental cast measurement and analysis", Hua Xi Kou Qiang Yi Xue Za Zhi, 23, pp.329~331 (2005)
  28. Kamegawa M, "3D morphological measurements of dental casts with occlusal relationship using microfocus X-ray CT", Dent Mater J, 27, pp.549~554 (2008)
  29. Kamegawa M, "3D morphological assessment of occlusal treatment by measuring dental castswith a micro-focus X-ray CT", J Oral Rehabil, 35, pp.382~389 (2008)

관련 논문AI추천

The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materialsCarlos Flores-Mir, Giseon Heo, Usama Nassar, Ysidora Torrealba대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제3호알지네이트 인상체에서 제작된 치과용 석고 모형의 정확도에 대한 삼차원 디지털 분석이진한, 주용훈대한턱관절교합학회 · 구강회복응용과학지2015 · 제31권 제4호Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressionsHyeon-Shik Hwang, Sang-Mi Lee, Tingting Jiang, Xin Chang, Yanan Hou대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제3호Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray techniqueGabriel Krastl, Julia Buhler, Marie-Hélène Pastoret, Nicola Ursula Zitzmann, Roland Weiger대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제4호혼합 방법과 보관 시간이 알지네이트 인상재의 체적 안정성에 미치는 효과박은진, 방현지, 심현아, 조영은대한치과보철학회 · 대한치과보철학회지2020 · 제58권 제2호Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluationsChuang Bi, Fangfang Tian, Jiaming Zhao, Xingyu Wang, Zhe Qu대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제4호

이 간행물의 다른 논문 (10건)