PURPOSE. Accurate information is essential in dentistry. The image information of missing teeth is used in optically based medical equipment in prosthodontic treatment. To evaluate oral scanners, the standardized model was examined from cases of image recognition errors of linear discriminant analysis (LDA), and a model that combines the variables with reference to ISO 12836:2015 was designed. MATERIALS AND METHODS. The basic model was fabricated by applying 4 factors to the tooth profile (chamfer, groove, curve, and square) and the bottom surface. Photo-type and video-type scanners were used to analyze 3D images after image capture. The scans were performed several times according to the prescribed sequence to distinguish the model from the one that did not form, and the results confirmed it to be the best. RESULTS. In the case of the initial basic model, a 3D shape could not be obtained by scanning even if several shots were taken. Subsequently, the recognition rate of the image was improved with every variable factor, and the difference depends on the tooth profile and the pattern of the floor surface. CONCLUSION. Based on the recognition error of the LDA, the recognition rate decreases when the model has a similar pattern. Therefore, to obtain the accurate 3D data, the difference of each class needs to be provided when developing a standardized model.
Abstract
PURPOSE. Accurate information is essential in dentistry. The image information of missing teeth is used in optically based medical equipment in prosthodontic treatment. To evaluate oral scanners, the standardized model was examined from cases of image recognition errors of linear discriminant analysis (LDA), and a model that combines the variables with reference to ISO 12836:2015 was designed. MATERIALS AND METHODS. The basic model was fabricated by applying 4 factors to the tooth profile (chamfer, groove, curve, and square) and the bottom surface. Photo-type and video-type scanners were used to analyze 3D images after image capture. The scans were performed several times according to the prescribed sequence to distinguish the model from the one that did not form, and the results confirmed it to be the best. RESULTS. In the case of the initial basic model, a 3D shape could not be obtained by scanning even if several shots were taken. Subsequently, the recognition rate of the image was improved with every variable factor, and the difference depends on the tooth profile and the pattern of the floor surface. CONCLUSION. Based on the recognition error of the LDA, the recognition rate decreases when the model has a similar pattern. Therefore, to obtain the accurate 3D data, the difference of each class needs to be provided when developing a standardized model.
참고문헌 (7)
- Syrek A, "Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling", J Dent, 38, pp.553~559 (2010)
- Thalji G, "Prosthodontic management of implant therapy", Dent Clin North Am, 58, pp.207~225 (2014)
- Moghaddam B, "Probabilistic visual learning for object representation", IEEE Trans Pattern Anal Mach Intell, 19, pp.696~710 (1997)
- 강성관, "서베일런스에서 피셔의 선형 판별 분석을 이용한 사람 검출의 성능 향상", 디지털융복합연구, 11(12), pp.295~302 (2013), 한국디지털정책학회
- V. Proceedings of The 1995 IEEE Workshop, "1995", IEEE
- Moura DC, "Real-scale 3D models of the scoliotic spine from biplanar radiography without calibration objects", Comput Med Imaging Graph, 38, pp.580~585 (2014)
- Wang J, "Real-time computer-generated integral imaging and 3D image calibration for augmented reality surgical navigation", Comput Med Imaging Graph, 40, pp.147~159 (2015)