본문 바로가기
KERD
논문KCI 등재

Accuracy of new implant impression technique using dual arch tray and bite impression coping

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at α=.05. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

Abstract

PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at α=.05. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

참고문헌 (32)

  1. Humphries RM, "The accuracy of implant master casts constructed from transfer impressions", Int J Oral Maxillofac Implants, 5, pp.331~336 (1990)
  2. Sahin S, "The significance of passive framework fit in implant prosthodontics: current status", Implant Dent, 10, pp.85~92 (2001)[DOI]
  3. Goodacre CJ, "Clinical complications with implants and implant prostheses", J Prosthet Dent, 90, pp.121~132 (2003)[DOI]
  4. Sones AD, "Complications with osseointegrated implants", J Prosthet Dent, 62, pp.581~585 (1989)[DOI]
  5. Wee AG, "Strategies to achieve fit in implant prosthodontics: a review of the literature", Int J Prosthodont, 12, pp.167~178 (1999)
  6. Assif D, "Accuracy of implant impression techniques", Int J Oral Maxillofac Implants, 11, pp.216~222 (1996)
  7. Henry PJ, "An alternative method for the production of accurate casts and occlusal records in osseointegrated implant rehabilitation", J Prosthet Dent, 58, pp.694~697 (1987)[DOI]
  8. Barrett MG, "The accuracy of six impression techniques for osseointegrated implants", J Prosthodont, 2, pp.75~82 (1993)[DOI]
  9. Carr AB, "Comparison of impression techniques for a five-implant mandibular model", Int J Oral Maxillofac Implants, 6, pp.448~455 (1991)
  10. Assuncao WG, "Evaluation of transfer impressions for osseointegrated implants at various angulations", Implant Dent, 13, pp.358~366 (2004)[DOI]
  11. Del'Acqua MA, "Accuracy of impression and pouring techniques for an implant-supported prosthesis", Int J Oral Maxillofac Implants, 23, pp.226~236 (2008)
  12. Phillips KM, "The accuracy of three implant techniques: a three dimensional analysis", Int J Oral Maxillofac Implants, 9, pp.533~540 (1994)
  13. Cabral LM, "Comparative analysis of 4 impression techniques for implants", Implant Dent, 16, pp.187~194 (2007)[DOI]
  14. Herbst D, "Evaluation of impression accuracy for osseointegrated implant supported superstructures", J Prosthet Dent, 83, pp.555~561 (2000)[DOI]
  15. Naconecy MM, "Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments", Int J Oral Maxillofac Implants, 19, pp.192~198 (2004)
  16. Wenz HJ, "Accuracy of impressions and casts using different implant impression techniques in a multi-implant system with an internal hex connection", Int J Oral Maxillofac Implants, 23, pp.39~47 (2008)
  17. Carr AB, "Comparison of impression techniques for a two-implant 15-degree divergent model", Int J Oral Maxillofac Implants, 7, pp.468~475 (1992)
  18. Conrad HJ, "Accuracy of two impression techniques with angulated implants", J Prosthet Dent, 97, pp.349~356 (2007)[DOI]
  19. Parker MH, "Comparison of occlusal contacts in maximum intercuspation for two impression techniques", J Prosthet Dent, 78, pp.255~259 (1997)[DOI]
  20. Hsu CC, "A comparative analysis of the accuracy of implant transfer techniques", J Prosthet Dent, 69, pp.588~593 (1993)[DOI]
  21. Spector MR, "An evaluation of impression techniques for osseointegrated implants", J Prosthet Dent, 63, pp.444~447 (1990)[DOI]
  22. Liou AD, "Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials", Int J Prosthodont, 6, pp.377~383 (1993)
  23. Rashidan N, "Accuracy of implant impressions with different impression coping types and shapes", Clin Implant Dent Relat Res, 14, pp.218~225 (2012)[DOI]
  24. Cox JR, "A clinical pilot study of the dimensional accuracy of double-arch and complete-arch impressions", J Prosthet Dent, 87, pp.510~515 (2002)[DOI]
  25. Parfitt GJ, "Measurement of the physiological mobility of individual teeth in an axial direction", J Dent Res, 39, pp.608~618 (1960)[DOI]
  26. Goodkind RJ, "Mandibular flexure in opening and closing movements", J Prosthet Dent, 30, pp.134~138 (1973)[DOI]
  27. Ceyhan JA, "A clinical study comparing the three-dimensional accuracy of a working die generated from two dual-arch trays and a complete-arch custom tray", J Prosthet Dent, 90, pp.228~234 (2003)[DOI]
  28. Stimmelmayr M, "Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw", Clin Oral Investig, 17, pp.1929~1935 (2013)[DOI]
  29. Stimmelmayr M, "Evaluation of impression accuracy for a four-implant mandibular model-a digital approach", Clin Oral Investig, 16, pp.1137~1142 (2012)[DOI]
  30. Papaspyridakos P, "Full-arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit", Clin Oral Implants Res, 27, pp.1099~1105 (2016)[DOI]
  31. Papaspyridakos P, "Digital versus conventional implant impressions for edentulous patients: accuracy outcomes", Clin Oral Implants Res, 27, pp.465~472 (2016)
  32. 이예규, "Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition", The Journal of Advanced of Prosthodontics, 7(6), pp.460~467 (2015), 대한치과보철학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (10건)