본문 바로가기
KERD
논문KCI 등재

Accuracy of five implant impression technique: effect of splinting materials and methods

1

조회

0

다운로드

3

인용

0

참고문헌

초록

PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey’s studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in zaxis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.

Abstract

PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey’s studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in zaxis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.

참고문헌 (43)

  1. Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)
  2. Zarb GA, "The longitudinal clinical effectiveness of osseointegrated dental implants in anterior partially edentulous patients", Int J Prosthodont, 6, pp.180~188 (1993)
  3. Goll GE, "Production of accurately fitting full-arch implant frameworks: Part I-Clinical procedures", J Prosthet Dent, 66, pp.377~384 (1991)
  4. Rangert B, "Forces and moments on Branemark implants", Int J Oral Maxillofac Implants, 4, pp.241~247 (1989)
  5. Zarb GA, "The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto Study. Part II: The prosthetic results", J Prosthet Dent, 64, pp.53~61 (1990)
  6. Jemt T, "Failures and complications in 391 consecutively inserted fixed prostheses supported by Bra􀆆nemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup", Int J Oral Maxillofac Implants, 6, pp.270~276 (1991)
  7. Jemt T, "In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw", Int J Oral Maxillofac Implants, 11, pp.151~158 (1996)
  8. Kallus T, "Loose gold screws frequently occur in fullarch fixed prostheses supported by osseointegrated implants after 5 years", Int J Oral Maxillofac Implants, 9, pp.169~178 (1994)
  9. Johansson G, "Complications, supplementary treatment, and maintenance in edentulous arches with implant-supported fixed prostheses", Int J Prosthodont, 3, pp.89~92 (1990)
  10. Tan KB, "Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses", Int J Prosthodont, 6, pp.346~363 (1993)
  11. Stumpel LJ 3rd, "Adhesive abutment cylinder luting", J Prosthet Dent, 69, pp.398~400 (1993)
  12. Humphries RM, "The accuracy of implant master casts constructed from transfer impressions", Int J Oral Maxillofac Implants, 5, pp.331~336 (1990)
  13. Tautin FS, "Impression making for osseointegrated dentures", J Prosthet Dent, 54, pp.250~251 (1985)
  14. Henry PJ, "An alternative method for the production of accurate casts and occlusal records in osseointegrated implant rehabilitation", J Prosthet Dent, 58, pp.694~697 (1987)
  15. Carr AB, "Full-arch implant framework casting accuracy: preliminary in vitro observation for in vivo testing", J Prosthodont, 2, pp.2~8 (1993)
  16. Assif D, "Comparative accuracy of implant impression procedures", Int J Periodontics Restorative Dent, 12, pp.112~121 (1992)
  17. Barrett MG, "The accuracy of six impression techniques for osseointegrated implants", J Prosthodont, 2, pp.75~82 (1993)
  18. Carr AB, "Comparison of impression techniques for a five-implant mandibular model", Int J Oral Maxillofac Implants, 6, pp.448~455 (1991)
  19. Gordon GE, "The effect of tray selection on the accuracy of elastomeric impression materials", J Prosthet Dent, 63, pp.12~15 (1990)
  20. Rueda LJ, "The effect of using custom or stock trays on the accuracy of gypsum casts", Int J Prosthodont, 9, pp.367~373 (1996)
  21. Burns J, "Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays", J Prosthet Dent, 89, pp.250~255 (2003)
  22. Branemark PI, "Tissue-integrated prostheses. Osseointegration in clinical dentistry", pp.11~12 (1985), Quintessence
  23. Hsu CC, "A comparative analysis of the accuracy of implant transfer techniques", J Prosthet Dent, 69, pp.588~593 (1993)
  24. Phillips KM, "The accuracy of three implant impression techniques: A three-dimensional analysis", Int J Oral Maxillofac Implants, 9, pp.533~540 (1994)
  25. Herbst D, "Evaluation of impression accuracy for osseointegrated implant supported superstructures", J Prosthet Dent, 83, pp.555~561 (2000)
  26. Spector MR, "An evaluation of impression techniques for osseointegrated implants", J Prosthet Dent, 63, pp.444~447 (1990)
  27. Inturregui JA, "Evaluation of three impression techniques for osseointegrated oral implants", J Prosthet Dent, 69, pp.503~509 (1993)
  28. Burawi G, "A comparison of the dimensional accuracy of the splinted and unsplinted impression techniques for the Bone-Lock implant system", J Prosthet Dent, 77, pp.68~75 (1997)
  29. Assif D, "Accuracy of implant impression techniques", Int J Oral Maxillofac Implants, 11, pp.216~222 (1996)
  30. Naconecy MM, "Evaluation of the accuracy of 3 transfer techniques for implant-supported prostheses with multiple abutments", Int J Oral Maxillofac Implants, 19, pp.192~198 (2004)
  31. Vigolo P, "Evaluation of the accuracy of three techniques used for multiple implant abutment impressions", J Prosthet Dent, 89, pp.186~192 (2003)
  32. Cabral LM, "Comparative analysis of 4 impression techniques for implants", Implant Dent, 16, pp.187~194 (2007)
  33. 류석민, "치과 임플랜트 인상채득 방법에 따른 주모형의 정확성에 대한 비교 연구", 대한치과보철학회지, 40(1), pp.18~29 (2002), 대한치과보철학회
  34. Bra􀆆nemark PI, "Osseointegration and its experimental background", J Prosthet Dent, 50, pp.399~410 (1983)
  35. Millington ND, "Inaccurate fit of implant superstructures. Part 1: Stresses generated on the superstructure relative to the size of fit discrepancy", Int J Prosthodont, 8, pp.511~516 (1995)
  36. Jemt T, "Prosthesis misfit and marginal bone loss in edentulous implant patients", Int J Oral Maxillofac Implants, 11, pp.620~625 (1996)
  37. Jemt T, "Accuracy of implant-supported prostheses in the edentulous jaw: analysis of precision of fit between cast goldalloy frameworks and master casts by means of a three-dimensional photogrammetric technique", Clin Oral Implants Res, 6, pp.172~180 (1995)
  38. Mojon P, "Polymerization shrinkage of index and pattern acrylic resins", J Prosthet Dent, 64, pp.684~688 (1990)
  39. "ANSI-ADA Specification No.25 Dental gypsum products", American dental association council on dental materials and equipment, ~ (2000)
  40. Dumbrigue HB, "Prefabricated acrylic resin bars for splinting implant transfer copings", J Prosthet Dent, 84, pp.108~110 (2000)
  41. Assif D, "Accuracy of implant impression splinted techniques: effect of splinting material", Int J Oral Maxillofac Implants, 14, pp.885~888 (1999)
  42. Nissan J, "Impression technique for partially edentulous patients", J Prosthet Dent, 88, pp.103~104 (2002)
  43. Eid N, "An implant impression technique using a plaster splinting index combined with a silicone impression", J Prosthet Dent, 92, pp.575~577 (2004)

관련 논문AI추천

이 간행물의 다른 논문 (8건)