Effect of different surface treatments on the shear bond strength of luting cements used with implant-supported prosthesis: An in vitro study
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
PURPOSE. The aim of this study was to investigate the shear bond strength of luting cements used with implant retained restorations on to titanium specimens after different surface treatments. MATERIALS AND METHODS. One hundred twenty disc shaped specimens were used. They were divided into three groups considering the surface treatments (no treatment, sandblasting, and oxygen plasma treatment). Water contact angle of specimens were determined. The specimens were further divided into four subgroups (n=10) according to applied cement types: polycarboxylate cement (Adhesor Carbofine-AC), temporary zinc oxide free cement (Temporary Cement- ZOC), non eugenol provisional cement for implant retained prosthesis (Premier Implant Cement-PI), and non eugenol acrylic-urethane polymer based provisional cement for implant luting (Cem Implant Cement-CI). Shear bond strength values were evaluated. Two-way ANOVA test and Regression analysis were used to statistical analyze the results. RESULTS. Overall shear bond strength values of luting cements defined in sandblasting groups were considerably higher than other surfaces (P<.05). The cements can be ranked as AC > CI > PI > ZOC according to shear bond strength values for all surface treatment groups (P<.05). Water contact angles of surface treatments (control, sandblasting, and plasma treatment group) were 76.17° ± 3.99, 110.45° ± 1.41, and 73.80° ± 4.79, respectively. Regression analysis revealed that correlation between the contact angle of different surfaces and shear bond strength was not strong (P>.05). CONCLUSION. The retentive strength findings of all luting cements were higher in sandblasting and oxygen plasma groups than in control groups. Oxygen plasma treatment can improve the adhesion ability of titanium surfaces without any mechanical damage to titanium structure.
Abstract
PURPOSE. The aim of this study was to investigate the shear bond strength of luting cements used with implant retained restorations on to titanium specimens after different surface treatments. MATERIALS AND METHODS. One hundred twenty disc shaped specimens were used. They were divided into three groups considering the surface treatments (no treatment, sandblasting, and oxygen plasma treatment). Water contact angle of specimens were determined. The specimens were further divided into four subgroups (n=10) according to applied cement types: polycarboxylate cement (Adhesor Carbofine-AC), temporary zinc oxide free cement (Temporary Cement- ZOC), non eugenol provisional cement for implant retained prosthesis (Premier Implant Cement-PI), and non eugenol acrylic-urethane polymer based provisional cement for implant luting (Cem Implant Cement-CI). Shear bond strength values were evaluated. Two-way ANOVA test and Regression analysis were used to statistical analyze the results. RESULTS. Overall shear bond strength values of luting cements defined in sandblasting groups were considerably higher than other surfaces (P<.05). The cements can be ranked as AC > CI > PI > ZOC according to shear bond strength values for all surface treatment groups (P<.05). Water contact angles of surface treatments (control, sandblasting, and plasma treatment group) were 76.17° ± 3.99, 110.45° ± 1.41, and 73.80° ± 4.79, respectively. Regression analysis revealed that correlation between the contact angle of different surfaces and shear bond strength was not strong (P>.05). CONCLUSION. The retentive strength findings of all luting cements were higher in sandblasting and oxygen plasma groups than in control groups. Oxygen plasma treatment can improve the adhesion ability of titanium surfaces without any mechanical damage to titanium structure.
참고문헌 (42)
- Worni A, "Retrievability of implant-supported crowns when using three different cements : a controlled clinical trial", Int J Prosthodont, 28, pp.22~29 (2015)
- Vigolo P, "Cemented versus screw-retained implant-supported single-tooth crowns : a 4-year prospective clinical study", Int J Oral Maxillofac Implants, 19, pp.260~265 (2004)
- Mehl C, "Retrievability of implant-retained crowns following cementation", Clin Oral Implants Res, 19, pp.1304~1311 (2008)
- Gultekin P, "Cement selection for implant-supported crowns fabricated with different luting space settings", J Prosthodont, 22, pp.112~119 (2013)
- Canullo L, "Clinical evaluation of an improved cementation technique for implant-supported restorations : a randomized controlled trial", Clin Oral Implants Res, 27, pp.1492~1499 (2016)
- Garg P, "Retentiveness of various luting agents used with implant-supported prosthesis : an in vitro study", J Oral Implantol, 40, pp.649~654 (2014)
- Michalakis KX, "Cement-retained versus screw-retained implant restorations : a critical review", Int J Oral Maxillofac Implants, 18, pp.719~728 (2003)
- Kim Y, "The comparison of provisional luting agents and abutment surface roughness on the retention of provisional implant-supported crowns", J Prosthet Dent, 95, pp.450~455 (2006)
- Wadhwani C, "Bond strength and interactions of machined titanium-based alloy with dental cements", J Prosthet Dent, 114, pp.660~665 (2015)
- Rodrigues DC, "Titanium corrosion mechanisms in the oral environment: A retrieval study", Materials(Basel), 6, pp.5258~5274 (2013)
- Nicholson JW, "The biocompatibility of resinmodified glass-ionomer cements for dentistry", Dent Mater, 24, pp.1702~1708 (2008)
- Nematollahi F, "Cement selection for cement-retained implant-supported prostheses : A literature review", J Prosthodont, 25, pp.599~606 (2016)
- Jugdev J, "The effect of air abrasion of metal implant abutments on the tensile bond strength of three luting agents used to cement implant superstructures : an in vitro study", Int J Oral Maxillofac Implants, 29, pp.784~790 (2014)
- Ajay R, "Effect of surface modifications on the retention of cement-retained implant crowns under fatigue loads : An in vitro study", J Pharm Bioallied Sci, 9, pp.S154~S160 (2017)
- Elsaka SE, "Effect of surface pretreatments on the bonding strength and durability of self-adhesive resin cements to machined titanium", J Prosthet Dent, 109, pp.113~120 (2013)
- Cano-Batalla J, "Influence of abutment height and surface roughness on in vitro retention of three luting agents", Int J Oral Maxillofac Implants, 27, pp.36~41 (2012)
- Lewinstein I, "An in vitro assessment of circumferential grooves on the retention of cement-retained implant-supported crowns", J Prosthet Dent, 106, pp.367~372 (2011)
- Al Hamad KQ, "The effects of height and surface roughness of abutments and the type of cement on bond strength of cement-retained implant restorations", Clin Oral Implants Res, 22, pp.638~644 (2011)
- Larsson Wexell C, "Bone response to surface-modified titanium implants : studies on the early tissue response to implants with different surface characteristics", Int J Biomater, 2013, pp.412482~ (2013)
- Duske K, "Atmospheric plasma enhances wettability and cell spreading on dental implant metals", J Clin Periodontol, 39, pp.400~407 (2012)
- Tseng WY, "Low pressure radio-frequency oxygen plasma induced oxidation of titanium--surface characteristics and biological effects", PLoS One, 8, pp.e84898~ (2013)
- Henningsen A, "Photofunctionalization and non-thermal plasma activation of titanium surfaces", Clin Oral Investig, 22, pp.1045~1054 (2018)
- Fusun Ozer, "Shear bond strength of luting cements to fixed superstructure metal surfaces under various seating forces", The Journal of Advanced of Prosthodontics, 10(5), pp.340~346 (2018), 대한치과보철학회[DOI]
- Özcan M, "Surface conditioning protocol for the adhesion of resin-based cements to base and noble alloys:How to condition and why?", J Adhes Dent, 17, pp.372~373 (2015)
- Seker E, "Effect of atmospheric plasma versus conventional surface treatments on the adhesion capability between self-adhesive resin cement and titanium surface", J Adv Prosthodont, 7, pp.249~256 (2015)
- Vogelsang A, "Locally resolved analysis of polymer surface functionalization by an atmospheric pressure argon microplasma jet with air entrainment", Plasma Process Polym, 7, pp.16~24 (2010)
- Wadhwani CP, "Implant cementation : clinical problems and solutions", Dent Today, 31, pp.56~ (2012)
- Reddy AK, "Comparative evaluation and influence on shear bond strength of incorporating silver, zinc oxide, and titanium dioxide nanoparticles in orthodontic adhesive", J Orthod Sci, 5, pp.127~131 (2016)
- Sun J, "Improving performance of dental resins by adding titanium dioxide nanoparticles", Dent Mater, 27, pp.972~982 (2011)
- Ramp MH, "Tensile bond strengths of provisional luting agents used with an implant system", J Prosthet Dent, 81, pp.510~514 (1999)
- Gumus HO, "Evaluation and comparison of the film thicknesses of six temporary cements before and after thermal cycling", Niger J Clin Pract, 21, pp.1656~1661 (2018)
- Naumova EA, "Influence of luting materials on the retention of cemented implant-supported crowns: An in vitro study", Materials, 11, pp.E1853~ (2018)
- El-Helbawy NG, "Comparison of Oxygen Plasma Treatment and Sandblasting of Titanium Implant-Abutment Surface on Bond Strength and Surface Topography", Int J Oral Maxillofac Implants, 31, pp.555~562 (2016)
- Mansour A, "Comparative evaluation of casting retention using the ITI solid abutment with six cements", Clin Oral Implants Res, 13, pp.343~348 (2002)
- Hagaman EW, "Solid-state 17O NMR study of benzoic acid adsorption on metal oxide surfaces", Solid State Nucl Magn Reson, 41, pp.60~67 (2012)
- Michalakis K, "The effect of thermal cycling and air abrasion on cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures", Int J Oral Maxillofac Implants, 22, pp.569~574 (2007)
- Wilmart Labriaga, "Effect of non-thermal plasma on the shear bond strength of resin cements to Polyetherketoneketone (PEKK)", The Journal of Advanced of Prosthodontics, 10(6), pp.408~414 (2018), 대한치과보철학회[DOI]
- Maíra do Prado, "The effects of non-thermal plasma and conventional treatments on the bond strength of fiber posts to resin cement", Restorative Dentistry and Endodontics, 42(2), pp.125~133 (2017), 대한치과보존학회
- Al Jabbari YS, "Effect of sandblasting conditions on alumina retention in representative dental alloys", Dent Mater J, 31, pp.249~255 (2012)
- Lümkemann N, "Different surface modifications combined with universal adhesives : the impact on the bonding properties of zirconia to composite resin cement", Clin Oral Investig, 23, pp.3941~3950 (2019)
- Matthes R, "Fibroblast growth on zirconia ceramic and titanium disks after application with cold atmospheric pressure plasma devices or with antiseptics", Int J Oral Maxillofac Implants, 34, pp.809~818 (2019)
- Elias AB, "Effect of different times of nonthermal argon plasma treatment on the microtensile bond strength of self-adhesive resin cement to yttria-stabilized tetragonal zirconia polycrystal ceramic", J Prosthet Dent, 121, pp.485~491 (2019)
