Shear bond strength of luting cements to fixed superstructure metal surfaces under various seating forces
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
PURPOSE. In this study, the shear bond strengths (SBS) of luting cements to fixed superstructure metal surfaces under various seating forces were investigated. MATERIALS AND METHODS. Seven different cements [Polycarboxylate (PCC), Glass-Ionomer (GIC), Zinc phospahate (ZPC), Self-adhesive resin (RXU), Resin (C&B), and Temporary cements ((RXT) and (TCS))] were bonded to a total number of 224 square blocks (5×5×3 mm) made of one pure metal [Titanium (CP Ti) and two metal alloys [Gold-Platinum (Au-Pt) and Cobalt-Chrome (Co-Cr)] under 10 N and 50 N seating forces. SBS values were determined and data were analyzed with 3-way ANOVA. Pairwise comparisons and interactions among groups were analyzed with Tukey’s simultaneous confidence intervals. RESULTS. Overall mean scores indicated that Co-Cr showed the highest SBS values (1.96±0.4) (P<.00), while Au-Pt showed the lowest among all metals tested (1.57±0.4) (P<.00). Except for PCC/CP Ti, RXU/CP Ti, and GIC/Au-Pt factor level combinations (P<.00), the cements tested under 10 N seating force showed no significantly higher SBS values when compared to the values of those tested under 50 N seating force (P>.05). The PCC cement showed the highest mean SBS score (3.59±0.07) among all cements tested (P<.00), while the resin-based temporary luting cement RXT showed the lowest (0.39±0.07) (P<.00). CONCLUSION. Polycarboxylate cement provides reliable bonding performance to metal surfaces. Resin-based temporary luting cements can be used when retrievability is needed. GIC is not suitable for permanent cementation of fixed dental prostheses consisting of CP Ti or Au-Pt substructures.
Abstract
PURPOSE. In this study, the shear bond strengths (SBS) of luting cements to fixed superstructure metal surfaces under various seating forces were investigated. MATERIALS AND METHODS. Seven different cements [Polycarboxylate (PCC), Glass-Ionomer (GIC), Zinc phospahate (ZPC), Self-adhesive resin (RXU), Resin (C&B), and Temporary cements ((RXT) and (TCS))] were bonded to a total number of 224 square blocks (5×5×3 mm) made of one pure metal [Titanium (CP Ti) and two metal alloys [Gold-Platinum (Au-Pt) and Cobalt-Chrome (Co-Cr)] under 10 N and 50 N seating forces. SBS values were determined and data were analyzed with 3-way ANOVA. Pairwise comparisons and interactions among groups were analyzed with Tukey’s simultaneous confidence intervals. RESULTS. Overall mean scores indicated that Co-Cr showed the highest SBS values (1.96±0.4) (P<.00), while Au-Pt showed the lowest among all metals tested (1.57±0.4) (P<.00). Except for PCC/CP Ti, RXU/CP Ti, and GIC/Au-Pt factor level combinations (P<.00), the cements tested under 10 N seating force showed no significantly higher SBS values when compared to the values of those tested under 50 N seating force (P>.05). The PCC cement showed the highest mean SBS score (3.59±0.07) among all cements tested (P<.00), while the resin-based temporary luting cement RXT showed the lowest (0.39±0.07) (P<.00). CONCLUSION. Polycarboxylate cement provides reliable bonding performance to metal surfaces. Resin-based temporary luting cements can be used when retrievability is needed. GIC is not suitable for permanent cementation of fixed dental prostheses consisting of CP Ti or Au-Pt substructures.
참고문헌 (47)
- Lee A, "Screw- versus cement-retained implant restorations: current concepts", Implant Dent, 19, pp.8~15 (2010)[DOI]
- Mehl C, "Influence of cement film thickness on the retention of implant-retained crowns", J Prosthodont, 22, pp.618~625 (2013)[DOI]
- Mehl C, "Influence of abutment height and thermocycling on retrievability of cemented implant-supported crowns", Int J Oral Maxillofac Implants, 27, pp.1106~1115 (2012)
- Hebel KS, "Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry", J Prosthet Dent, 77, pp.28~35 (1997)[DOI]
- Breeding LC, "Use of luting agents with an implant system: Part I", J Prosthet Dent, 68, pp.737~741 (1992)[DOI]
- Heinemann F, "Retrospective evaluation of temporary cemented, tooth and implant supported fixed partial dentures", J Craniomaxillofac Surg, 34, pp.86~90 (2006)
- Chaar MS, "Prosthetic outcome of cement-retained implant-supported fixed dental restorations: a systematic review", J Oral Rehabil, 38, pp.697~711 (2011)[DOI]
- Mehl C, "In vitro influence of ultrasonic stress, removal force preload and thermocycling on the retrievability of implant-retained crowns", Clin Oral Implants Res, 23, pp.930~937 (2012)[DOI]
- Good ML, "Quantification of all-ceramic crown margin surface profile from tryin to 1-week post-cementation", J Dent, 37, pp.65~75 (2009)[DOI]
- Watanabe K, "Porcelain veneer bonding to enamel with plasma-arc light resin curing", Dent Mater J, 21, pp.61~68 (2002)[DOI]
- Carter SM, "The effects of die-spacing on post-cementation crown elevation and retention", Aust Dent J, 42, pp.192~198 (1997)[DOI]
- Dixon DL, "Use of luting agents with an implant system: Part II", J Prosthet Dent, 68, pp.885~890 (1992)[DOI]
- Vermilyea SG, "The effects of die relief agent on the retention of full coverage castings", J Prosthet Dent, 50, pp.207~210 (1983)[DOI]
- Hembree JH Jr, "Effect of die relief on reten- tion of cast crowns and inlays", Oper Dent, 4, pp.104~107 (1979)
- Haddad MF, "Cementation of prosthetic restorations: from conventional cementation to dental bonding concept", J Craniofac Surg, 22, pp.952~958 (2011)[DOI]
- Bagheri R, "Film thickness and flow properties of resin-based cements at different temperatures", J Dent (Shiraz), 14, pp.57~63 (2013)
- Wilson PR, "Low force cementation", J Dent, 24, pp.269~273 (1996)[DOI]
- Goracci C, "Microtensile bond strength and interfacial properties of self-etching and self-adhesive resin cements used to lute composite onlays under different seating forces", J Adhes Dent, 8, pp.327~335 (2006)
- Piemjai M, "Effect of seating force, margin design, and cement on marginal seal and retention of complete metal crowns", Int J Prosthodont, 14, pp.412~416 (2001)
- Fonseca RG, "Effect of metal primers on bond strength of resin cements to base metals", J Prosthet Dent, 101, pp.262~268 (2009)[DOI]
- Yoshida K, "Shear bond strengths of three resin cements used with three adhesive primers for metal", J Prosthet Dent, 75, pp.254~261 (1996)[DOI]
- Matinlinna JP, "Silane adhesion mechanism in dental applications and surface treatments: A review", Dent Mater, 34, pp.13~28 (2018)[DOI]
- Ozcan M, "Surface conditioning protocol for the adhesion of resin-based cements to base and noble alloys: How to condition and why", J Adhes Dent, 17, pp.372~373 (2015)
- Cherkasski B, "The effect of oscillation, low seating force and dentine surface treatment on pulpward pressure transmission during crown cementation: a laboratory study", J Oral Rehabil, 30, pp.957~963 (2003)[DOI]
- Black S, "Measurement of forces applied during the clinical cementation of dental crowns", Physiol Meas, 14, pp.387~392 (1993)[DOI]
- Montgomery DC, "Design and analysis of experiments", pp.174~188 (2012), John Wiley & Sons
- Jorgensen KD, "Factors affecting the film thickness of zinc phosphate cements", Acta Odontol Scand, 18, pp.479~490 (1960)[DOI]
- D’Souza R, "A better bond: Luting simplified", Int J Prosthet Rest Dent, 2, pp.77~81 (2012)
- Mitchell CA, "The influence of luting cement on the probabilities of survival and modes of failure of cast full-coverage crowns", Dent Mater, 16, pp.198~206 (2000)[DOI]
- Sen D, "Cementation", pp.9~31 (2012), Quintessence Publishing
- Mansour A, "Comparative evaluation of casting retention using the ITI solid abutment with six cements", Clin Oral Implants Res, 13, pp.343~348 (2002)[DOI]
- Hattar S, "Shear bond strength of self-adhesive resin cements to base metal alloy", J Prosthet Dent, 111, pp.411~415 (2014)[DOI]
- Bauer J, "Influence of alloy microstructure on the microshear bond strength of basic alloys to a resin luting cement", Braz Dent J, 23, pp.490~495 (2012)[DOI]
- Raeisosadat F, "Bond strength of resin cements to noble and base metal alloys with different surface treatments", J Dent (Tehran), 11, pp.596~603 (2014)
- Kious AR, "Film thicknesses of recently introduced luting cements", J Prosthet Dent, 101, pp.189~192 (2009)[DOI]
- Anusavice KJ, "Phillips' Science of dental materials", pp.621~654 (2003), W.B. Saunders Company
- Sakaguchi RL, "Craig's restorative dental materials", pp.327~347 (2012), Elsevier Mosby
- Almilhatti HJ, "Adhesive bonding of resin composite to various titanium surfaces using different metal conditioners and a surface modification system", J Appl Oral Sci, 21, pp.590~596 (2013)[DOI]
- Fawzy AS, "Effect acidic and alkaline", heat treatments on the bond strength of different luting cements to commercially pure titanium, 2009, pp.37, 255~263
- Kern M, "Durability of resin bonds to pure titanium", J Prosthodont, 4, pp.16~22 (1995)[DOI]
- "Technical data sheet RelyX U200", 3M ESPE, ~ (2011)
- "Safety data sheet C&B", BISCO, Inc., ~ (2015)
- Yoshida K, "Effect of three adhesive primers for a noble metal on the shear bond strengths of three resin cements", J Oral Rehabil, 28, pp.14~19 (2001)[DOI]
- McIntyre FM, "The effect of film thickness on the bond strength of polycarboxylate cement", Int J Prosthodont, 7, pp.461~467 (1994)
- Orsi IA, "In vitro tensile strength of luting cements on metallic substrate", Braz Dent J, 25, pp.136~140 (2014)[DOI]
- Subramaniam P, "Retentive strength of luting cements for stainless steel crowns: an in vitro study", J Clin Pediatr Dent, 34, pp.309~312 (2010)[DOI]
- Hibino Y, "Relationship between the strength of glass ionomers and their adhesive strength to metals", Dent Mater, 18, pp.552~557 (2002)[DOI]
