PURPOSE. The present study was intended to evaluate the effect of soldering techniques with infrared ray and gas torch under different gap distances (0.3 mm and 0.5 mm) on the tensile strength and surface porosity formation in Ni-Cr base metal alloy. MATERIALS AND METHODS. Thirty five dumbbell shaped Ni-Cr alloy specimens were prepared and assigned to 5 groups according to the soldering method and the gap distance. For the soldering methods, gas torch (G group) and infrared ray (IR group) were compared and each group was subdivided by corresponding gap distance (0.3 mm: G3 and IR3, 0.5 mm: G5, IR5). Specimens of the experimental groups were sectioned in the middle with a diamond disk and embedded in solder blocks according to the predetermined distance. As a control group, 7 specimens were prepared without sectioning or soldering. After the soldering procedure, a tensile strength test was performed using universal testing machine at a crosshead speed 1 mm/min. The proportions of porosity on the fractured surface were calculated on the images acquired through the scanning electronic microscope. RESULTS. Every specimen of G3, G5, IR3 and IR5 was fractured on the solder joint area. However, there was no significant difference between the test groups (P > .05). There was a negative correlation between porosity formation and tensile strength in all the specimens in the test groups (P < .05). CONCLUSION. There was no significant difference in ultimate tensile strength of joints and porosity formations between the gas-oxygen torch soldering and infrared ray soldering technique or between the gap distance of 0.3 mm and 0.5 mm.
Abstract
PURPOSE. The present study was intended to evaluate the effect of soldering techniques with infrared ray and gas torch under different gap distances (0.3 mm and 0.5 mm) on the tensile strength and surface porosity formation in Ni-Cr base metal alloy. MATERIALS AND METHODS. Thirty five dumbbell shaped Ni-Cr alloy specimens were prepared and assigned to 5 groups according to the soldering method and the gap distance. For the soldering methods, gas torch (G group) and infrared ray (IR group) were compared and each group was subdivided by corresponding gap distance (0.3 mm: G3 and IR3, 0.5 mm: G5, IR5). Specimens of the experimental groups were sectioned in the middle with a diamond disk and embedded in solder blocks according to the predetermined distance. As a control group, 7 specimens were prepared without sectioning or soldering. After the soldering procedure, a tensile strength test was performed using universal testing machine at a crosshead speed 1 mm/min. The proportions of porosity on the fractured surface were calculated on the images acquired through the scanning electronic microscope. RESULTS. Every specimen of G3, G5, IR3 and IR5 was fractured on the solder joint area. However, there was no significant difference between the test groups (P > .05). There was a negative correlation between porosity formation and tensile strength in all the specimens in the test groups (P < .05). CONCLUSION. There was no significant difference in ultimate tensile strength of joints and porosity formations between the gas-oxygen torch soldering and infrared ray soldering technique or between the gap distance of 0.3 mm and 0.5 mm.
참고문헌 (27)
- Blustein R, "A reliable technique of post soldering of nonprecious ceramic units", J Prosthet Dent, 36, pp.112~114 (1976)
- Huget EF, "Characterization of two ceramicbase-metal alloys", J Prosthet Dent, 40, pp.637~641 (1978)
- Moffa JP, "An evaluation of nonprecious alloys for use with porcelain veneers.Part I.Physical properties", J Prosthet Dent, 30, pp.424~431 (1973)
- Nikellis I, "Effect of soldering on the metalceramic bond strength of an Ni-Cr base alloy", J Prosthet Dent, 94, pp.435~439 (2005)
- Shillingburg HT, "Fundamentals of Fixed Prosthodontics. 3rd ed", pp.509~ (1997), Quintessence Publishing
- Anwar EM, "Effect of different gap distances on the tensile strength and microstructure of infra-red soldered joints", Cairo Dent J, 20, pp.149~155 (2004)
- Marshall AG, "An investigation of the tensile strength of nickel-chromium alloy dental solder joints", J Prosthet Dent, 52, pp.666~672 (1984)
- Rasmussen EJ, "An investigation of tensile strength of dental solder joints", J Prosthet Dent, 41, pp.418~423 (1979)
- Watanabe I, "Tensile strength of soldered gold alloy joints", J Prosthet Dent, 78, pp.260~266 (1997)
- el-Ebrashi MK, "Experimental stress analysis of dental restorations.VII.Structural design and stress analysis of fixed partial dentures", J Prosthet Dent, 23, pp.177~186 (1970)
- Kaylakie WG, "Comparative tensile strengths of nonnoble dental alloy solders", J Prosthet Dent, 53, pp.455~462 (1985)
- Anusavice KJ, "Flexure test evaluation of presoldered base metal alloys", J Prosthet Dent, 54, pp.507~517 (1985)
- Townsend LW, "Soldering nonnoble alloys", J Prosthet Dent, 50, pp.51~53 (1983)
- Stackhouse JA Jr, "Assembly of dental units by soldering", J Prosthet Dent, 18, pp.131~139 (1967)
- Stade EH, "Preceramic and postceramic solder joints", J Prosthet Dent, 34, pp.527~532 (1975)
- Willis LM, "Distortion in dental soldering as affected by gap distance", J Prosthet Dent, 43, pp.272~278 (1980)
- Ryge G, "Porosities in dental gold castings", J Am Dent Assoc, 54, pp.746~754 (1957)
- Carlberg T, "Soldering of dental alloys under vacuum by IR-heating", Dent Mater, 2, pp.279~283 (1986)
- Tehini GE, "Comparative analysis of two techniques for soldered connectors", J Prosthet Dent, 69, pp.16~19 (1993)
- Cattaneo G, "Comparison of tensile strength of solder joints by infrared and conventional torch technique", J Prosthet Dent, 68, pp.33~37 (1992)
- Chaves M, "Effects of three soldering techniques on the strength of high-palladium alloy solder joints", J Prosthet Dent, 79, pp.677~684 (1998)
- Cheng AC, "Mechanical properties of metal connectors soldered by gas torch versus an infrared technique", J Prosthodont, 2, pp.103~109 (1993)
- Ryge G, "Dental soldering procedures", Dent Clin North Am, 2, pp.747~757 (1958)
- Anusavice KJ, "Inert gas presoldering of nickelchromium alloys", J Prosthet Dent, 55, pp.317~323 (1986)
- Nicholls JI, "Tensile strength of presoldered and postsoldered joints", J Prosthet Dent, 53, pp.476~482 (1985)
- Sobieralski JA, "Tensile strengths and microscopic analysis of nickel-chromium base metal postceramic solder joints", J Prosthet Dent, 58, pp.35~42 (1987)
- Cheng AC, "Investigation of stiffness and microstructure of joints soldered with gas-oxygen torch and infrared methods", J Prosthet Dent, 72, pp.8~15 (1994)