Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar (Cendres et Me′taux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.
Abstract
Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar (Cendres et Me′taux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.
참고문헌 (15)
- Branemark PI, "Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period", Scand J Plast Reconstr Surg Suppl, 16, pp.1~132 (1997)
- Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)
- Albrektsson T, "Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants", J Periodontol, 59, pp.287~296 (1988)
- Degidi M, "Immediate functional loading of edentulous maxilla: a 5-year retrospective study of 388 titanium implants", J Periodontol, 76, pp.1016~1024 (2005)
- Ibañez JC, "Immediate occlusal loading of double acid-etched surface titanium implants in 41 consecutive full-arch cases in the mandible and maxilla: 6- to 74-month results", J Periodontol, 76, pp.1972~1981 (2005)
- Chiapasco M, "Implant-retained mandibular overdentures with immediate loading: a 3- to 8-year prospective study on 328 implants", Clin Implant Dent Relat Res, 5, pp.29~38 (2003)
- Turkyilmaz I, "2-year clinical report of patients treated with two loading protocols for mandibular overdentures: early versus conventional loading", J Periodontol, 77, pp.1998~2004 (2006)
- MacEntee MI, "A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: three-year results", J Prosthet Dent, 93, pp.28~37 (2005)
- Davis DM, "The maintenance requirements of mandibular overdentures stabilized by Astra Tech implants using three different attachment mechanisms-balls, magnets, and bars; 3-year results", Eur J Prosthodont Restor Dent, 8, pp.131~134 (2000)
- Misch CE, "Classification of partially edentulous arches for implant dentistry", Int J Oral Implantol, 4, pp.7~13 (1987)
- Attard NJ, "Immediate and early implant loading protocols: a literature review of clinical studies", J Prosthet Dent, 94, pp.242~258 (2005)
- Albrektsson T, "Direct bone anchorage of dental implants", J Prosthet Dent, 50, pp.255~261 (1983)
- Cannizzaro G, "Immediate functional loading of implants placed with flapless surgery in the edentulous maxilla: 1-year follow-up of a single cohort study", Int J Oral Maxillofac Implants, 22, pp.87~95 (2007)
- Chiapasco M, "Implant-retained mandibular overdentures with Branemark system MKII implants: a prospective comparative study between delayed and immediate loading", Int J Oral Maxillofac Implants, 16, pp.537~546 (2001)
- Chiapasco M, "Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases", Clin Oral Implants Res, 8, pp.48~57 (1997)