Implant-supported overdenture is a reliable treatment option for the patients with edentulous mandible when they have difficulty in using complete dentures. Several options have been used for implant-supported overdenture attachments. Among these, bar attachment system has greater retention and better maintainability than others. SFI-Bar(R) is prefabricated and can be adjustable at chairside. Therefore, laboratory procedures such as soldering and welding are unnecessary, which leads to fewer errors and lower costs. A 67-year-old female patient presented, complaining of mobility of lower anterior teeth with old denture. She had been wearing complete denture in the maxilla and removable partial denture in the mandible with severe bone loss. After extracting the teeth, two implants were placed in front of mental foramen, and SFI-Bar(R) was connected. A tube bar was seated to two adapters through large ball joints and fixation screws, connecting each implant. The length of the tube bar was adjusted according to inter-implant distance. Then, a female part was attached to the bar beneath the new denture. This clinical report describes two-implant-supported overdenture using the SFI-Bar(R) system in a mandibular edentulous patient.

Abstract

Implant-supported overdenture is a reliable treatment option for the patients with edentulous mandible when they have difficulty in using complete dentures. Several options have been used for implant-supported overdenture attachments. Among these, bar attachment system has greater retention and better maintainability than others. SFI-Bar(R) is prefabricated and can be adjustable at chairside. Therefore, laboratory procedures such as soldering and welding are unnecessary, which leads to fewer errors and lower costs. A 67-year-old female patient presented, complaining of mobility of lower anterior teeth with old denture. She had been wearing complete denture in the maxilla and removable partial denture in the mandible with severe bone loss. After extracting the teeth, two implants were placed in front of mental foramen, and SFI-Bar(R) was connected. A tube bar was seated to two adapters through large ball joints and fixation screws, connecting each implant. The length of the tube bar was adjusted according to inter-implant distance. Then, a female part was attached to the bar beneath the new denture. This clinical report describes two-implant-supported overdenture using the SFI-Bar(R) system in a mandibular edentulous patient.

참고문헌 (13)

  1. Hakan Bilhan, "Complication rates and patient satisfaction with removable dentures", The Journal of Advanced of Prosthodontics, 4(2), pp.109~115 (2012), 대한치과보철학회
  2. Takeshita S, "Stress analysis of mandibular two-implant overdenture with different attachment systems", Dent Mater J, 30, pp.928~934 (2011)
  3. van Kampen F, "Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function", Clin Oral Implants Res, 14, pp.720~726 (2003)
  4. Fenlon MR, "Association between the accuracy of intermaxillary relations and complete denture usage", J Prosthet Dent, 81, pp.520~525 (1999)
  5. Feine JS, "The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients", Gerodontology, 19, pp.3~4 (2002)
  6. Vercruyssen M, "Long-term, retrospective evaluation (implant and patient-centred outcome) of the two-implants-supported overdenture in the mandible. Part 1: survival rate", Clin Oral Implants Res, 21, pp.357~365 (2010)
  7. Thomason JM, "Two implant retained overdentures-a review of the literature supporting the McGill and York consensus statements", J Dent, 40, pp.22~34 (2012)
  8. 홍준원, "Immediate placement and functional loading of implants on canine with fixed partial denture for a patient having canine protected occlusion: a case report", The Journal of Advanced of Prosthodontics, 4(1), pp.52~56 (2012), 대한치과보철학회
  9. Esposito M, "Interventions for replacing missing teeth: different times for loading dental implants", Cochrane Database Syst Rev, 18(2), pp.003878~ (2007)
  10. Esposito M, "Interventions for replacing missing teeth: 1- versus 2- stage implant placement", Cochrane Database Syst Rev, 8(3), pp.006698~ (2009)
  11. Stoumpis C, "To splint or not to splint oral implants in the implant-supported overdenture therapy? A systematic literature review", J Oral Rehabil, 38, pp.857~869 (2011)
  12. Spazzin AO, "Effects of horizontal misfit and bar framework material on the stress distribution of an overdenture-retaining bar system: a 3D finite element analysis", J Prosthodont, 20, pp.517~522 (2011)
  13. Deslis A, "Numerical investigations of the loading behaviour of a prefabricated non-rigid bar system", Ann Anat (2012)

관련 논문AI추천

Immediate loading on mandibular edentulous patient with SFI Bar® overdenture김진영, 김하영, 신상완, 정창모, 허중보, Sarah Qadeer대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제1호하악 완전 무치악 환자에서 solitary attachment를 연결한 임시 보철물로 조기 부하를 가한 후, 조립식 바를 이용한 최종 임플란트 지지 피개의치 제작증례박도현, 윤미정, 이소현, 전영찬, 정창모, 허중보대한치과의사협회 · 대한치과의사협회지2015 · 제54권 제1호Implant overdenture using a locator bar system by drill and tapping technique in a mandible edentulous patient: a case report김민수, 윤미정, 전영찬, 정창모, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2012 · 제4권 제2호무치악 환자에서 기성 조립식 bar를 이용한 임플란트 피개의치 증례소나영, 하승룡, 홍영기대한치과보철학회 · 대한치과보철학회지2016 · 제54권 제1호기성품 바 어태치먼트 시스템인 SFI bar를 이용한 피개의치 전악수복 증례박상원, 방몽숙, 신은정, 양홍서, 윤귀덕, 임현필, 주한성대한치과보철학회 · 대한치과보철학회지2014 · 제52권 제4호임플랜트지지 피개의치를 이용한 무치악환자의 구강회복김자영, 박주미, 박찬운, 송광엽, 안승근, 이정준, 이홍석대한턱관절교합학회 · 구강회복응용과학지2008 · 제24권 제1호

이 간행물의 다른 논문 (13건)