본문 바로가기
KERD
논문KCI 등재

Implant overdenture impressions using a dynamic impression concept

0

조회

0

다운로드

5

인용

0

참고문헌

키워드

초록

A dynamic impression is a functional impression that records the functional movement of the patient’ own muscle and muscle attachment. This process reduces the number of random factors. This article describes a method for making a special tray using a dynamic impression concept that was made from provisional dentures used for implant healing. The individual tray is used to make a wash-impression to record the features of the mucosa in detail. The main advantage of this technique is that it provides a functional relationship of the implant components to the supporting tissues without overextension because provisional denture had been used for 2 months and the border length of individual tray was nearly the same as that of provisional denture. The delivery of the prosthesis constructed using this impression technique is time-saving because there is no need for border molding and there are fewer post-insertion appliance adjustments.

Abstract

A dynamic impression is a functional impression that records the functional movement of the patient’ own muscle and muscle attachment. This process reduces the number of random factors. This article describes a method for making a special tray using a dynamic impression concept that was made from provisional dentures used for implant healing. The individual tray is used to make a wash-impression to record the features of the mucosa in detail. The main advantage of this technique is that it provides a functional relationship of the implant components to the supporting tissues without overextension because provisional denture had been used for 2 months and the border length of individual tray was nearly the same as that of provisional denture. The delivery of the prosthesis constructed using this impression technique is time-saving because there is no need for border molding and there are fewer post-insertion appliance adjustments.

참고문헌 (10)

  1. Chen IC., "Freedom of rotation of selected overdenture attachments : an in vitro study", J Prosthet Dent, 106, pp.78~86 (2011)
  2. Uludag B., "An alternate pressure-free functional impression technique for implant-retained overdentures", J Oral Implantol, 36, pp.205~207 (2010)
  3. Uludag B., "Alternate functional impression technique for implant-retained overdentures", J Prosthet Dent, 97, pp.242~243 (2007)
  4. Uludag B., "An alternative impression technique for implant-retained overdentures with locator attachments", J Oral Implantol, 36, pp.451~453 (2010)
  5. Jannesar S., "A dual impression technique for implant overdentures", J Prosthodont, 16, pp.327~329 (2007)
  6. Cho GC., "An alternative altered cast technique for a distal extension removable partial denture", J Calif Dent Assoc, 25, pp.377~380 (1997)
  7. Razek MK., "Assessment of tissue conditioning materials for functional impressions", J Prosthet Dent, 42, pp.376~380 (1979)
  8. McCarthy JA., "Tissue conditioners as functional impression materials", J Oral Rehabil, 5, pp.357~364 (1978)
  9. Wilson HJ., "The assessment of temporary soft materials used in prosthetics", Br Dent J, 126, pp.303~306 (1969)
  10. Elsyad MA., "A comparison of mandibular denture base deformation with different impression techniques for implant overdentures", Clin Oral Implants Res, 24, pp.127~133 (2013)

관련 논문AI추천