Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose. This study aimed to compare the bite force (BF) between complete dentures and implant overdentures (IODs) retained by two mandibular implants. Additionally, we evaluated the quality of life (QoL) and patient satisfaction among individuals using IODs. In addition, the effects of demographic parameters such as age and sex, and clinical parameters such as implant length, implant diameter, attachment height, attachment color, and interimplant distance on BF, QoL, and patient satisfaction were evaluated. Materials and methods. A total of 51 edentulous patients rehabilitated with the maxillary complete dentures and mandibular IODs retained by two implants were included in this study. BF was measured using a force meter pre- and post-implant in the same patients. Oral health-related quality of life (OHRQoL) was assessed with the Oral Health Impact Profile (OHIP-14) and patient satisfaction was assessed with the Visual Analog Scale (VAS) questionnaires. Results. It was found that BF values were statistically higher for IODs than complete dentures (P < .001). In terms of attachment height of the OHIP scores, there was a significant difference in the psychological disability and social disability domains (P < .05). When examining the change in patient satisfaction as a function of sex, it was found that mandibular retention satisfaction differed significantly by sex (P < .05), but there was no significant difference in the other domains. Conclusion. Within the limitations of this study, it was observed that the BF increased after the use of IODs. Several factors, including age, interimplant distance, attachment height, and attachment color, were found to impact OHRQoL. Sex and implant diameter were identified as factors affecting patient satisfaction.
Abstract
Purpose. This study aimed to compare the bite force (BF) between complete dentures and implant overdentures (IODs) retained by two mandibular implants. Additionally, we evaluated the quality of life (QoL) and patient satisfaction among individuals using IODs. In addition, the effects of demographic parameters such as age and sex, and clinical parameters such as implant length, implant diameter, attachment height, attachment color, and interimplant distance on BF, QoL, and patient satisfaction were evaluated. Materials and methods. A total of 51 edentulous patients rehabilitated with the maxillary complete dentures and mandibular IODs retained by two implants were included in this study. BF was measured using a force meter pre- and post-implant in the same patients. Oral health-related quality of life (OHRQoL) was assessed with the Oral Health Impact Profile (OHIP-14) and patient satisfaction was assessed with the Visual Analog Scale (VAS) questionnaires. Results. It was found that BF values were statistically higher for IODs than complete dentures (P < .001). In terms of attachment height of the OHIP scores, there was a significant difference in the psychological disability and social disability domains (P < .05). When examining the change in patient satisfaction as a function of sex, it was found that mandibular retention satisfaction differed significantly by sex (P < .05), but there was no significant difference in the other domains. Conclusion. Within the limitations of this study, it was observed that the BF increased after the use of IODs. Several factors, including age, interimplant distance, attachment height, and attachment color, were found to impact OHRQoL. Sex and implant diameter were identified as factors affecting patient satisfaction.
참고문헌 (42)
- Feine JS, "The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients", Gerodontology, 19, pp.3~4 (2002)
- Thomason JM, "Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients--the York Consensus Statement", Br Dent J, 207, pp.185~186 (2009)
- Geckili O, "Comparison of patient satisfaction, quality of life, and bite force between elderly edentulous patients wearing mandibular two implant-supported overdentures and conventional complete dentures after 4 years", Spec Care Dentist, 32, pp.136~141 (2012)
- Srinivasan M, "Mandibular two-implant overdentures with CAD-CAM milled bars with distal extensions or retentive anchors : a randomized controlled trial", Clin Oral Implants Res, 31, pp.1207~1222 (2020)
- Srinivasan M, "Implant overdentures retained by self-aligning stud-type attachments : a clinical report", J Prosthet Dent, 123, pp.6~14 (2020)
- Passia N, "Influence of the number of implants in the edentulous mandible on chewing efficacy and oral health-related quality of life-a within-subject design study", Clin Oral Implants Res, 33, pp.1030~1037 (2022)
- Mahanna FF, "Satisfaction and oral health-related quality of life of different attachments used for implant-retained overdentures in subjects with resorbed mandibles : a crossover trial", Int J Oral Maxillofac Implants, 35, pp.423~431 (2020)
- Doornewaard R, "Improvement of quality of life with implant-supported mandibular overdentures and the effect of implant type and surgical procedure on bone and soft tissue stability : a three-year prospective split-mouth trial", J Clin Med, 8, pp.773~ (2019)
- Geckili O, "Impact of mandibular two-implant retained overdentures on life quality in a group of elderly Turkish edentulous patients", Arch Gerontol Geriatr, 53, pp.233~236 (2011)
- Schimmel M, "Implants for elderly patients", Periodontol 2000, 73, pp.228~240 (2017)
- Koc D, "Bite force and influential factors on bite force measurements : a literature review", Eur J Dent, 4, pp.223~232 (2010)
- Levartovsky S, "Maximal bite force measured via digital bite force transducer in subjects with or without dental implants-a pilot study", Appl Sci, 12, pp.1544~ (2022)
- De Bruyn H, "The current use of patient-centered", reported outcomes in implant dentistry : a systematic review, 2015, pp.26(Suppl 11), 45~56
- Reissmann DR, "Alignment of oral health-related with health-related quality of life assessment", J Prosthodont Res, 60, pp.69~71 (2016)
- Wang Y, "Patient satisfaction and oral health-related quality of life 10 years after implant placement", BMC Oral Health, 14, pp.21~ (2021)[DOI]
- Gündoğar H, "Effect of peri-implant disease on oral health-related quality of life in geriatric patients", Gerodontology, 38, pp.414~421 (2021)
- Duong HY, "Oral health-related quality of life of patients rehabilitated with fixed and removable implant-supported dental prostheses", Periodontol 2000, 88, pp.201~237 (2022)
- Mumcu E, "The effect of attachment type and implant number on satisfaction and quality of life of mandibular implant-retained overdenture wearers", Gerodontology, 29, pp.e618~23 (2012)
- Ettinger RL, "Geriatric dental curriculum and the needs of the elderly", Spec Care Dentist, 4, pp.207~213 (1984)
- Cawood JI, "A classification of the edentulous jaws", Int J Oral Maxillofac Surg, 17, pp.232~236 (1988)
- Kaya MS, "Masticatory parameters of children with and without clinically diagnosed caries in permanent dentition", Eur J Paediatr Dent, 18, pp.116~120 (2017)
- Müller F, "Implant-supported mandibular overdentures in very old adults : a randomized controlled trial", J Dent Res, 92(12 Suppl), pp.154S~60S (2013)
- Mumcu G, "Oral health related quality of life is affected by disease activity in Behçet’s disease", Oral Dis, 12, pp.145~151 (2006)
- Geçkili O, "The effect of demographic factors, denture age, and bite force on quality of life and patient satisfaction of complete denture wearers", Cumhuriyet Dent J, 15, pp.7~15 (2012)
- Bilhan H, "The influence of implant number and attachment type on maximum bite force of mandibular overdentures : a retrospective study", Gerodontology, 29, pp.e116~20 (2012)
- van Kampen FM, "The influence of various attachment types in mandibular implant-retained overdentures on maximum bite force and EMG", J Dent Res, 81, pp.170~173 (2002)
- Rismanchian M, "Effect of implants on maximum bite force in edentulous patients", J Oral Implantol, 35, pp.196~200 (2009)
- Caloss R, "Does long-term use of unstable dentures weaken jaw muscles?", J Oral Rehabil, 37, pp.256~261 (2010)
- Caloss R, "The effect of denture stability on bite force and muscular effort", J Oral Rehabil, 38, pp.434~439 (2011)
- van der Bilt A, "Assessment of mastication with implications for oral rehabilitation : a review", J Oral Rehabil, 38, pp.754~780 (2011)
- Schimmel M, "Masticatory performance and maximum bite and lip force depend on the type of prosthesis", Int J Prosthodont, 30, pp.565~572 (2017)
- Geckili O, "The influence of momentary retention forces on patient satisfaction and quality of life of two-implant-retained mandibular overdenture wearers", Int J Oral Maxillofac Implants, 30, pp.397~402 (2015)
- Enkling N, "Chewing efficiency, bite force and oral health-related quality of life with narrow diameter implants - a prospective clinical study: results after one year", Clin Oral Implants Res, 28, pp.476~482 (2017)
- Pan S, "Does mandibular edentulous bone height affect prosthetic treatment success?", J Dent, 38, pp.899~907 (2010)
- Geckili O, "The influence of interimplant distance in mandibular overdentures supported by two implants on patient satisfaction and quality of life", Int J Prosthodont, 28, pp.19~21 (2015)
- Michelinakis G, "The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants : initial retention values", Int J Prosthodont, 19, pp.507~512 (2006)
- Doukas D, "The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants : 6-month fatigue retention values", Int J Prosthodont, 21, pp.152~154 (2008)
- El Mekawy N, "Clinical evaluation of inter-implant distance influence on the wear characteristics of low-profile stud attachments used in mandibular implantretained overdentures", J Clin Exp Dent, 11, pp.e33~41 (2019)
- Mumcu E, "Assessment of the effect of clinical independent risk factors on marginal bone loss in 2-implant-supported locator-retained mandibular overdentures", J Oral Implantol, 45, pp.207~212 (2019)
- Ebadian B, "Stress analysis of mandibular implant-retained overdenture with independent attachment system : effect of restoration space and attachment height", Gen Dent, 63, pp.61~67 (2015)
- Ying Z, "Influence of attachment height and shape on lateral force transmission in implant overdenture treatment", Int J Prosthodont, 30, pp.586~591 (2017)
- Brandt S, "Ball versus Locator® attachments : a retrospective study on prosthetic maintenance and effect on oral-health-related quality of life", Materials(Basel), 14, pp.1051~ (2021)