본문 바로가기
KERD
논문KCI 등재

Three-dimensional analysis of the outcome of different scanning strategies in virtual interocclusal registration

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations

Abstract

PURPOSE. The purpose of this in vitro study was to assess whether scanning strategies of virtual interocclusal record (VIR) affect the accuracy of VIR during intraoral scanning. MATERIALS AND METHODS. Five pairs of reference cubes were added to the digital upper and lower dentitions of a volunteer, which were printed into resin casts. Subsequently, the resin casts were articulated in the maximal intercuspal position in a mechanical articulator and scanned with an industrial computed tomography system, of which the VIR was served as a reference VIR. The investigated VIR of the upper and lower jaws of the resin master cast were recorded with an intraoral scanner according to 9 designed scanning strategies. Then, the deviation between the investigated VIRs and reference VIR were analyzed, which were measured by the deviation of the distances of six selected reference points on the upper reference cubes in each digital cast to the XY-plane between the investigated VIRs and reference VIR. RESULTS. For the deviation in the right posterior dentitions, RP group (only scanning of right posterior dentitions) showed the smallest deviation. Besides, BP group (scanning of bilateral posterior dentitions) showed the smallest deviation in the left posterior dentitions. Moreover, LP group (scanning of left posterior dentitions) showed the smallest deviation in the anterior dentitions. For the deviation of full dental arches, BP group showed the smallest deviation. CONCLUSION. Different scanning strategies of VIR can influence the accuracy of alignment of virtual dental casts. Appropriate scanning strategies of VIR should be selected for different regions of interest and edentulous situations

참고문헌 (28)

  1. Güth JF, "Accuracy of five intraoral scanners compared to indirect digitalization", Clin Oral Investig, 21, pp.1445~1455 (2017)
  2. Wismeijer D, "Patients’ preferences when comparing analogue implant impressions using a polyether impression material versus digital impressions(Intraoral Scan)of dental implants", Clin Oral Implants Res, 25, pp.1113~1118 (2014)
  3. Belur D, "An alternative digital workflow for fabricating a mandibular implant-supported complete fixed dental prosthesis with limited restorative space : A clinical report", J Prosthet Dent, 120, pp.1~4 (2018)
  4. van der Zande MM, "Dental practitioners and a digital future : an initial exploration of barriers and incentives to adopting digital technologies", Br Dent J, 215, pp.E21~ (2013)
  5. Ries JM, "Three-dimensional analysis of the accuracy of conventional and completely digital interocclusal registration methods", J Prosthet Dent, 128, pp.994~1000 (2022)
  6. Renne W, "Evaluation of the accuracy of 7 digital scanners : An in vitro analysis based on 3-dimensional comparisons", J Prosthet Dent, 118, pp.36~42 (2017)
  7. Wang ZY, "The influence of crown coverage on the accuracy of static guided implant surgery in partially edentulous models : An in vitro study", J Dent, 115, pp.103882~ (2021)
  8. Gómez-Polo M, "Influence of rescanning mesh holes and stitching procedures on the complete-arch scanning accuracy of an intraoral scanner : An in vitro study", J Dent, 110, pp.103690~ (2021)
  9. Freilich MA, "Principles for selecting interocclusal records for articulation of dentate and partially dentate casts", J Prosthet Dent, 68, pp.361~367 (1992)
  10. Davies S, "Reliability of recording static and dynamic occlusal contact marks using transparent acetate sheet", J Prosthet Dent, 94, pp.458~461 (2005)
  11. Ren S, "Accuracy of virtual interocclusal records for partially edentulous patients", J Prosthet Dent, 123, pp.860~865 (2020)
  12. Solaberrieta E, "Determining the requirements, section quantity, and dimension of the virtual occlusal record", J Prosthet Dent, 115, pp.52~56 (2016)
  13. Solaberrieta E, "Intraoral digital impressions for virtual occlusal records : section quantity and dimensions", Biomed Res Int, 2016, pp.7173824~ (2016)
  14. Park JH, "Digital workflow for a dental prosthesis that considers lateral mandibular relation", J Prosthet Dent, 117, pp.340~344 (2017)
  15. Wong KY, "Three-dimensional accuracy of digital static interocclusal registration by three intraoral scanner systems", J Prosthodont, 27, pp.120~128 (2018)
  16. 윤달선, "Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study", 대한치과교정학회지, 48(4), pp.262~267 (2018), 대한치과교정학회
  17. Edher F, "The accuracy of virtual interocclusal registration during intraoral scanning", J Prosthet Dent, 120, pp.904~912 (2018)
  18. Arslan Y, "Comparison of maximum intercuspal contacts of articulated casts and virtual casts requiring posterior fixed partial dentures", J Prosthodont, 26, pp.594~598 (2017)
  19. Villarraga-Gómez H, "Dimensional metrology with X-ray CT : A comparison with CMM measurements on internal features and compliant structures", Precis Eng, 51, pp.291~307 (2018)
  20. Renne W, "Evaluation of the accuracy of 7 digital scanners : An in vitro analysis based on 3-dimensional comparisons", J Prosthet Dent, 118, pp.36~42 (2017)
  21. Hayama H, "Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible", J Prosthodont Res, 62, pp.347~352 (2018)
  22. Schmidt A, "Torsion and linear accuracy in intraoral scans obtained with different scanning principles", J Prosthodont Res, 64, pp.167~174 (2020)
  23. Kanjanasavitree P, "Comparison of different artificial landmarks and scanning patterns on the complete-arch implant intraoral digital scans", J Dent, 125, pp.104266~ (2022)
  24. Kim JE, "Accuracy of intraoral digital impressions using an artificial landmark", J Prosthet Dent, 117, pp.755~761 (2017)
  25. Abduo J, "Accuracy of intraoral scanners : A systematic review of influencing factors", Eur J Prosthodont Restor Dent, 26, pp.101~121 (2018)
  26. Revilla-León M, "Influence of the number of teeth and location of the virtual occlusal record on the accuracy of the maxillo-mandibular relationship obtained by using an intraoral scanner", J Prosthodont (2022)[DOI]
  27. Moon YG, "Comparison of the accuracy of intraoral scans between complete-arch scan and quadrant scan", Prog Orthod, 21, pp.36~ (2020)
  28. Iwaki Y, "Dimensional accuracy of optical bite registration in single and multiple unit restorations", Oper Dent, 38, pp.309~315 (2013)

관련 논문AI추천

Recording maximal intercuspation and border positions of the mandible with intraoral scanner using the acquisition software’s multi-occlusion functionIhab Hammad, Noha Morsy대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제4호A novel method for testing accuracy of bite registration using intraoral scannersDemetrios J. Halazonetis, Lydia Kakali대한치과교정학회 · 대한치과교정학회지2023 · 제53권 제4호Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods김소연, 이규복, 이근우, 이두형, 이재목, 이청희, 마이항나, Hai Yen Mai대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제2호Accuracy comparison of buccal bite scans by five intra-oral scanners전진, 박지만, 허성주대한턱관절교합학회 · 구강회복응용과학지2018 · 제34권 제1호Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studiesCarlos Enrique Cuevas-Suárez, Gilbert Jorquera, Juan Carlos Hernández-Cabanillas, Juan Eliezer Zamarripa-Calderón, Louis Hardan, Monika Lukomska-Szymanska, Rim Bourgi, Sinan Ghishan대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제6호Effect of scan path on accuracy of complete arch intraoral scan고경호, 박찬진, 조리라, 최의준, 허윤혁대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제6호

이 간행물의 다른 논문 (5건)