본문 바로가기
KERD
논문KCI 등재

Removing Lipemia in Serum/Plasma Samples: A Multicenter Study

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: Lipemia, a significant source of analytical errors in clinical laboratory settings, should be removed prior to measuring biochemical parameters. We investigated whether lipemia in serum/plasma samples can be removed using a method that is easier and more practicable than ultracentrifugation, the current reference method. Methods: Seven hospital laboratories in Spain participated in this study. We first compared the effectiveness of ultracentrifugation (108,200×g) and high-speed centrifugation (10,000×g for 15 minutes) in removing lipemia. Second, we compared high-speed centrifugation with two liquid-liquid extraction methods—LipoClear (StatSpin, Norwood, USA), and 1,1,2-trichlorotrifluoroethane (Merck, Darmstadt, Germany). We assessed 14 biochemical parameters: serum/plasma concentrations of sodium ion, potassium ion, chloride ion, glucose, total protein, albumin, creatinine, urea, alkaline phosphatase, gamma-glutamyl transferase, alanine aminotransferase, aspartate-aminotransferase, calcium, and bilirubin. We analyzed whether the differences between lipemia removal methods exceeded the limit for clinically significant interference (LCSI). Results: When ultracentrifugation and high-speed centrifugation were compared, no parameter had a difference that exceeded the LCSI. When high-speed centrifugation was compared with the two liquid-liquid extraction methods, we found differences exceeding the LCSI in protein, calcium, and aspartate aminotransferase in the comparison with 1,1,2-trichlorotrifluoroethane, and in protein, albumin, and calcium in the comparison with LipoClear. Differences in other parameters did not exceed the LCSI. Conclusions: High-speed centrifugation (10,000×g for 15 minutes) can be used instead of ultracentrifugation to remove lipemia in serum/plasma samples. LipoClear and 1,1,2-trichlorotrifluoroethane are unsuitable as they interfere with the measurement of certain parameters.

Abstract

Background: Lipemia, a significant source of analytical errors in clinical laboratory settings, should be removed prior to measuring biochemical parameters. We investigated whether lipemia in serum/plasma samples can be removed using a method that is easier and more practicable than ultracentrifugation, the current reference method. Methods: Seven hospital laboratories in Spain participated in this study. We first compared the effectiveness of ultracentrifugation (108,200×g) and high-speed centrifugation (10,000×g for 15 minutes) in removing lipemia. Second, we compared high-speed centrifugation with two liquid-liquid extraction methods—LipoClear (StatSpin, Norwood, USA), and 1,1,2-trichlorotrifluoroethane (Merck, Darmstadt, Germany). We assessed 14 biochemical parameters: serum/plasma concentrations of sodium ion, potassium ion, chloride ion, glucose, total protein, albumin, creatinine, urea, alkaline phosphatase, gamma-glutamyl transferase, alanine aminotransferase, aspartate-aminotransferase, calcium, and bilirubin. We analyzed whether the differences between lipemia removal methods exceeded the limit for clinically significant interference (LCSI). Results: When ultracentrifugation and high-speed centrifugation were compared, no parameter had a difference that exceeded the LCSI. When high-speed centrifugation was compared with the two liquid-liquid extraction methods, we found differences exceeding the LCSI in protein, calcium, and aspartate aminotransferase in the comparison with 1,1,2-trichlorotrifluoroethane, and in protein, albumin, and calcium in the comparison with LipoClear. Differences in other parameters did not exceed the LCSI. Conclusions: High-speed centrifugation (10,000×g for 15 minutes) can be used instead of ultracentrifugation to remove lipemia in serum/plasma samples. LipoClear and 1,1,2-trichlorotrifluoroethane are unsuitable as they interfere with the measurement of certain parameters.

참고문헌 (18)

  1. Kroll M, "Evaluating interference caused by lipaemia", Clin Chem, 50, pp.1968~1969 (2004)
  2. Farrell CL, "Serum indices : managing assay interference", Ann Clin Biochem, 53, pp.527~538 (2016)
  3. Ryder KW, "Incidence and amount of turbidity, hemolysis, and icterus in serum from outpatients", Lab Med, 22, pp.415~418 (1991)
  4. Nikolac N, "Lipaemia: causes, interference mechanisms, detection and management", Biochem Med, 24, pp.57~67 (2014)
  5. Goldenberg NM, "An observational study of severe hypertriglyceridemia, hypertriglyceridemic acute pancreatitis, and failure of triglyceride-lowering therapy when estrogens are given to women with and without familial hypertriglyceridemia", Clin Chim Acta, 332, pp.11~19 (2003)
  6. Calmarza P, "Lipaemia interferences in routine clinical biochemical tests", Biochem Med, 21, pp.160~166 (2011)
  7. Walker PL, "Lipaemia: causes, consequences and solutions", Clin Chim Acta, 418, pp.30~32 (2013)
  8. Dimeski G, "Interference testing", Clin Biochem Rev, 29(S1), pp.S43~S48 (2008)
  9. Dimeski G, "Lipaemic samples: effective process for lipid reduction using high speed centrifugation compared with ultracentrifugation", Biochem Med, 21, pp.86~92 (2011)
  10. CLSI, "Hemolysis, icterus, and lipaemia", turbidity indices as indicators of interference in clinical laboratory analysis. CLSI C56, 2011
  11. Vermeer HJ, "Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids : a practical approach", Clin Chem Lab Med, 45, pp.114~119 (2007)
  12. Saracevic A, "The evaluation and comparison of consecutive high speed centrifugation and LipoClear® reagent for lipaemia removal", Clin Biochem, 47, pp.309~314 (2014)
  13. Bergmeyer HU, "Approved recommendation (1985) on IFCC methods for the measurement of catalytic concentration of enzymes. Part 3. IFCC method for alanine aminotransferase", J Clin Chem Clin Biochem, 24, pp.481~495 (1986)
  14. Bergmeyer HU, "Approved recommendation (1985) on IFCC methods for the measurement of catalytic concentration of enzymes. Part 2. IFCC Method for aspartate aminotransferase", J Clin Chem Clin Biochem, 24, pp.497~510 (1986)
  15. Tietz NW, "International Federation of Clinical Chemistry. IFCC methods for the measurement of catalytic concentration of enzymes, Part 5. IFCC method for alkaline phosphatase (orthophosphoric-monoester phosphohydrolase, alkaline optimum, EC 3.1.3.1)", J Clin Chem Clin Biochem, 21, pp.731~748 (1983)
  16. Szasz G, "New substrates for measuring gamma-glutamyl-transpeptidase activity", Z Klin Chem Klin Biochem, 12, pp.228~ (1974)
  17. Spanish Society of Clinical Biochemistry, "Criteria for the assessment of the analytical and clinical significance of interferences in clinical biochemistry", Quim Clínica, 14, pp.107~109 (1995)
  18. CLSI, "Statistical quality control for quantitative measurement procedures: principles and definitions; approved guideline. CLSI C24-A3", Clinical Laboratory Standards Institute, ~ (2006)

관련 논문AI추천

Proposal of Modified HIL-indices for Determining Hemolysis, Icterus and Lipemia Interference on the Beckman Coulter AU5800 Automated Platform임용관, 차영주대한진단검사의학회 · Laboratory Medicine Online2017 · 제7권 제2호Influence of a Regular, Standardized Meal on Clinical Chemistry AnalytesElisa Danese, Gabriel Lima-Oliveira, Geraldo Picheth, Gian Cesare Guidi, Gian Luca Salvagno, Giuseppe Lippi, Martina Montagnana, Matteo Gelati대한진단검사의학회 · Annals of Laboratory Medicine2012 · 제32권 제4호Evaluation of the Barricor Tube in 28 Routine Chemical Tests and Its Impact on Turnaround Time in an Outpatient Clinic김인숙, Lee Han Sol, Lee Sun Min, Moon Soo Young, Park Min Soon대한진단검사의학회 · Annals of Laboratory Medicine2021 · 제41권 제3호용혈, 황달 및 지질혈증: 자동화 임상화학분석기를 이용한 검사 결과 간섭 평가Jeong Ina, Jun Kyung Ran, Kim Won-Joo, Lee Sun Min, Oh Seung Hwan, Park Chul Min, Yoo Dong-Won대한진단검사의학회 · Laboratory Medicine Online2026 · 제16권 제1호Development of an Integrated Reporting System for Verifying Hemolysis, Icterus, and Lipemia in Clinical Chemistry Results어영, 김갑성, 김주원, 서동민, 신동훈, 윤갑준, 윤광로, 이만희, 이세일, 장재윤대한진단검사의학회 · Annals of Laboratory Medicine2014 · 제34권 제4호Comparison of Three Blood Collection Tubes for 35 Biochemical Analytes: The Becton Dickinson Barricor Tube, Serum Separating Tube, and Plasma Separating TubeOh Jongwon, Park Hyung-Doo, Shin Sunghwan대한진단검사의학회 · Annals of Laboratory Medicine2021 · 제41권 제1호

이 간행물의 다른 논문 (20건)