본문 바로가기
KERD
논문KCI 등재

Validity and Reliability of a Korean Version of the National Institutes of Health Stroke Scale

2

조회

0

다운로드

11

인용

0

참고문헌

키워드

초록

Background and Purpose The National Institutes of Health Stroke Scale (NIHSS) is a clinical assessment tool that is widely used in clinical trials and practice to evaluate stroke-related neurological deficits. The aim of this study was to determine the validity and reliability of the Korean version of the NIHSS (K-NIHSS) for evaluating Korean stroke patients. Methods The K-NIHSS was translated and adapted with regard to cultural and linguistic peculiarities. To examine its content validity, we quantified the Content Validity Index (CVI), which was rated by 11 stroke experts. The validity of the K-NIHSS was assessed by comparison with the Glasgow Coma Scale (GCS), the modified Rankin Scale (mRS), and the Barthel Index. The reliability of the K-NIHSS was evaluated using the unweighted kappa statistics for multiple raters and an intraclass correlation coefficient (ICC). Results The CVI of the K-NIHSS reached 0.91-1.00. The median K-NIHSS score at baseline was 3 (interquartile range, 2-7), and the mean±SD score was 6.0±6.6. The baseline K-NIHSS had a significantly negative correlation with the GCS at baseline and the Barthel Index after 90days. The K-NIHSS also had a significantly positive correlation with the mRS after 90 days. Facial paresis and dysarthria had moderate interrater reliability (unweighted kappa, 0.41-0.60);kappa values were substantial to excellent (unweighted kappa, >0.60) for all the other items. The ICC for the overall K-NIHSS score was 0.998. The intrarater reliability was acceptable, with a median kappa range of 0.524-1.000. Conclusions The K-NIHSS is a valid and reliable tool for assessing neurological deficits in Korean acute stroke patients.

Abstract

Background and Purpose The National Institutes of Health Stroke Scale (NIHSS) is a clinical assessment tool that is widely used in clinical trials and practice to evaluate stroke-related neurological deficits. The aim of this study was to determine the validity and reliability of the Korean version of the NIHSS (K-NIHSS) for evaluating Korean stroke patients. Methods The K-NIHSS was translated and adapted with regard to cultural and linguistic peculiarities. To examine its content validity, we quantified the Content Validity Index (CVI), which was rated by 11 stroke experts. The validity of the K-NIHSS was assessed by comparison with the Glasgow Coma Scale (GCS), the modified Rankin Scale (mRS), and the Barthel Index. The reliability of the K-NIHSS was evaluated using the unweighted kappa statistics for multiple raters and an intraclass correlation coefficient (ICC). Results The CVI of the K-NIHSS reached 0.91-1.00. The median K-NIHSS score at baseline was 3 (interquartile range, 2-7), and the mean±SD score was 6.0±6.6. The baseline K-NIHSS had a significantly negative correlation with the GCS at baseline and the Barthel Index after 90days. The K-NIHSS also had a significantly positive correlation with the mRS after 90 days. Facial paresis and dysarthria had moderate interrater reliability (unweighted kappa, 0.41-0.60);kappa values were substantial to excellent (unweighted kappa, >0.60) for all the other items. The ICC for the overall K-NIHSS score was 0.998. The intrarater reliability was acceptable, with a median kappa range of 0.524-1.000. Conclusions The K-NIHSS is a valid and reliable tool for assessing neurological deficits in Korean acute stroke patients.

참고문헌 (34)

  1. Goldstein LB, "Interrater reliability of the NIH stroke scale", Arch Neurol, 46, pp.660~662 (1989)
  2. Albanese MA, "Ensuring reliability of outcome measures in multicenter clinical trials of treatments for acute ischemic stroke. The program developed for the Trial of Org 10172 in Acute Stroke Treatment (TOAST)", Stroke, 25, pp.1746~1751 (1994)
  3. Kasner SE, "Reliability and validity of estimating the NIH stroke scale score from medical records", Stroke, 30, pp.1534~1537 (1999)
  4. Adams HP Jr, "Baseline NIH Stroke Scale score strongly predicts outcome after stroke: A report of the Trial of Org 10172 in Acute Stroke Treatment (TOAST)", Neurology, 53, pp.126~131 (1999)
  5. Lyden P, "Improved reliability of the NIH Stroke Scale using video training. NINDS TPA Stroke Study Group", Stroke, 25, pp.2220~2226 (1994)
  6. Goldstein LB, "Reliability of the National Institutes of Health Stroke Scale. Extension to non-neurologists in the context of a clinical trial", Stroke, 28, pp.307~310 (1997)
  7. Lyden P, "NIHSS training and certification using a new digital video disk is reliable", Stroke, 36, pp.2446~2449 (2005)
  8. Hacke W, "Association of outcome with early stroke treatment: pooled analysis of ATLANTIS, ECASS, and NINDS rt-PA stroke trials", Lancet, 363, pp.768~774 (2004)
  9. Lyden P, "Underlying structure of the National Institutes of Health Stroke Scale: results of a factor analysis. NINDS tPA Stroke Trial Investigators", Stroke, 30, pp.2347~2354 (1999)
  10. Lyden PD, "NINDS rtPA Stroke Study Group. A modified National Institutes of Health Stroke Scale for use in stroke clinical trials: preliminary reliability and validity", Stroke, 32, pp.1310~1317 (2001)
  11. Schlegel D, "Utility of the NIH Stroke Scale as a predictor of hospital disposition", Stroke, 34, pp.134~137 (2003)
  12. Lyden P, "National Institutes of Health Stroke Scale certification is reliable across multiple venues", Stroke, 40, pp.2507~2511 (2009)
  13. Nilanont Y, "Establishment of the Thai version of National Institute of Health Stroke Scale (NIHSS) and a validation st", J Med Assoc Thai, 93(1), pp.S171~S178 (2010)
  14. Sun TK, "Assessing reliability and validity of the Chinese version of the stroke scale: scale development", Int J Nurs Stud, 43, pp.457~463 (2006)
  15. Domínguez R, "Spanish cross-cultural adaptation and validation of the National Institutes of Health Stroke Scale", Mayo Clin Proc, 81, pp.476~480 (2006)
  16. Cincura C, "Validation of the National Institutes of Health Stroke Scale, modified Rankin Scale and Barthel Index in Brazil: the role of cultural adaptation and structured interviewing", Cerebrovasc Dis, 27, pp.119~122 (2009)
  17. Pezzella FR, "Development of the Italian version of the National Institutes of Health Stroke Scale: It-NIHSS", Stroke, 40, pp.2557~2559 (2009)
  18. Kang Y, "Parallel short forms for the Korean-Boston Naming Test (K-BNT)", J Korean Neurol Assoc, 18, pp.144~150 (2000)
  19. Waltz CF, "Nursing Research: Design, Statistics, and Computer Analysis" (1981), Davis
  20. Lynn MR, "Determination and quantification of content validity", Nurs Res, 35, pp.382~385 (1986)
  21. Rowley G, "Reliability and accuracy of the Glasgow Coma Scale with experienced and inexperienced users", Lancet, 337, pp.535~538 (1991)
  22. Fischer J, "The history of the Glasgow Coma Scale: implications for practice", Crit Care Nurs Q, 23, pp.52~58 (2001)
  23. Wilson JT, "Reliability of the modified Rankin Scale across multiple raters: benefits of a structured interview", Stroke, 36, pp.777~781 (2005)
  24. Mahoney FI, "Functional evaluation: the Barthel Index", Md State Med J 1965, 14, pp.56~61 (1965)
  25. Portney LG, "Foundations of Clinical Research: Applications to Practice. 2nd ed", pp.560~567 (2000), Prentice Hall Health
  26. Fleiss JL, "Statistical Methods for Rates and Proportions. 2nd ed" (1981), John Wiley & Sons
  27. Siegel S, "Nonparametric Statistics for the Behavioral Sciences. 2nd ed" (1988), McGraw-Hill
  28. Cheung RT, "Production and validation of Putonghua- and Cantonese-Chinese language National Institutes of Health Stroke Scale training and certification videos", Int J Stroke, 5, pp.74~79 (2010)
  29. Landis JR, "An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers", Biometrics, 33, pp.363~374 (1977)
  30. Shoukri MM, "Measures of Interobserver Agreement", pp.2004, Chapman and Hall
  31. 이경무, "한글판 미국 국립 보건원 뇌졸중 척도의 신뢰도 및 타당도-다기관 연구-", Annals of Rehabilitation Medicine, 28(5), pp.422~435 (2004), 대한재활의학회
  32. Hills NK, "Is the NIHSS certification process too lenient?", Cerebrovasc Dis, 27, pp.426~432 (2009)
  33. Schmülling S, "Training as a prerequisite for reliable use of NIH Stroke Scale", Stroke, 29, pp.1258~1259 (1998)
  34. Dewey HM, "Interrater reliability of the National Institutes of Health Stroke Scale: rating by neurologists and nurses in a community-based stroke incidence study", Cerebrovasc Dis, 9, pp.323~327 (1999)

관련 논문AI추천

한글판 미국 국립 보건원 뇌졸중 척도의 신뢰도 및 타당도-다기관 연구-김연희, 문승국, 박시운, 박주현, 유희정, 이경무, 이삼규, 장요한, 전민호, 한태륜대한재활의학회 · Annals of Rehabilitation Medicine2004 · 제28권 제5호The Korean Version of the Cognitive Assessment Scale for Stroke Patients (K-CASP): A Reliability and Validity Study박권희, 박기범, 박주현, 오현미, 이희원, 조아라, Jin-Youn Lee대한재활의학회 · Annals of Rehabilitation Medicine2017 · 제41권 제3호Stroke Impact Scale 3.0: Reliability and Validity Evaluation of the Korean Version구미정, 김동민, 김동아, 박경혜, 신준호, 오정은, 유세화, 윤정아, 이혜선, 최성욱, 호승희대한재활의학회 · Annals of Rehabilitation Medicine2017 · 제41권 제3호NIH Stroke Scale을 이용한 초기 뇌졸중 중증도에 대한 후향적 평가의 타당성권영대, 박기정, 부선희, 윤성상, 장혜정대한신경과학회 · 대한신경과학회지2006 · 제24권 제1호The Korean Version of the Fugl-Meyer Assessment: Reliability and Validity EvaluationCho Inyong, Choi Yujin, Hwang Jae Woong, Hwang Sung Hwan, Kim Eun-Hye, Kim Tae-lim, Lee Jung Ah, Lee Wang Jae, Park Jin Ho, Shin Joon-Ho대한재활의학회 · Annals of Rehabilitation Medicine2021 · 제45권 제2호Validation of Korean Version of the Oxford Cognitive Screen (K-OCS), a Post Stroke-Specific Cognitive Screening ToolChoi Sungwon, Eunyoung Cho, Kim MinYoung, Kim Rina, Lim Ikhyun, Nele Demeyere대한재활의학회 · Annals of Rehabilitation Medicine2025 · 제49권 제1호

이 간행물의 다른 논문 (12건)