단백전기영동법과 비탁법 간 혈청 IgG 값의 현저한 차이를 보인 다발골수종 1예
A Case of Multiple Myeloma Showing Marked Differences in Serum IgG Levels between Protein Electrophoresis and Turbidimetry
2
조회
0
다운로드
0
인용
0
참고문헌
초록
Abstract
We report a case of multiple myeloma showing marked differences in serum Immunoglobulin G (IgG) levels between serum protein electrophoresis and turbidimetry. A 47-yr old man was admitted to our hospital due to severe back pain and diagnosed as having IgG-kappa type multiple myeloma. Serum protein level was 14.4 g/dL at the time of diagnosis. Serum IgG level was 8.5 g/dL by serum protein electrophoresis, but 11.6 g/dL by turbidimetry. The patient’s clinical conditions had improved after receiving VAD (vincristine, adriamycin, dexamethasone) and VTD (vincristine, thalidomide, dexamethasone) chemotherapy and there were no differences in IgG levels between electrophoresis and turbidimetry when serum IgG levels were less than 3.0 g/dL. According to this, we considered that both protein electrophoresis and turbidimetry should be needed to quantify serum immunoglobulins for diagnosis and follow-up of the patients with monoclonal gammopathy. (Korean J Lab Med 2008;28:282-5)
참고문헌 (11)
- Durie BG, "A clinical staging system for multiple myeloma. Correlation of measured myeloma cell mass with presenting clinical features, response to treatment, and survival", Cancer, 36, pp.842~854 (1975)
- Greipp PR, "International staging system for multiple myeloma", J Clin Oncol, 23, pp.3412~2430 (2005)
- Katzel JA, "Multiple myeloma: charging toward a bright future", CA Cancer J Clin, 57, pp.301~318 (2007)
- McClatchey KD, "Clinical Laboratory Medicine", pp.1448~ (2002), Philadelphia; Lippincott Williams & Wilkins
- 강소영, "혈청 유리형경쇄참고치설정과 다발성골수종 환자들에서의 임상적 의의", 대한진단검사의학회지, 24(5), pp.273~278 (2004), 대한진단검사의학회
- Katzmann JA, "Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: relative sensitivity for detection of monoclonal light chains", Clin Chem, 48, pp.1437~1444 (2002)
- Bradwell AR, "Highly sensitive, automated immunoassay for immunoglobulin free light chains in serum and urine", Clin Chem, 47, pp.673~680 (2001)
- Chang CY, "Underestimation of monoclonal proteins by agarose serum protein electrophoresis", Ann Clin Lab Sci, 27, pp.123~129 (1997)
- "AACC 52nd Annual Meeting. Clin Chem 2000", 2000, 169~
- Snozek CL, "Comparison of bromcresol green and agarose protein electrophoresis for quantitation of serum albumin in multiple myeloma", Clin Chem, 53, pp.1099~1103 (2007)
- Attaelmannan M, "Understanding and identifying monoclonal gammopathies", Clin Chem, 46, pp.1230~1238 (2000)