Background: Early diagnosis of HIV infection reduces morbidity and mortality. Fourth-generation HIV detection assays are more sensitive because they can detect p24 antigen as well as anti-HIV antibodies. In this study, we evaluated the performance of a new fourth-generation ADVIA Centaur HIV antigen/antibody combo (CHIV) assay (Siemens Healthcare Diagnostics Inc., USA) for early detection of HIV infection and reduction of false positive rate. Methods: Four seroconversion panels were included. The third-generation ADVIA Centaur HIV 1/O/2 enhanced (EHIV) assay (Siemens Healthcare Diagnostics Inc., USA) and fourth-generation CHIV assay were used to test each panel for HIV infection. The presence of antigen was confirmed using HIV p24 antigen assay. To evaluate false-positivity and specificity, 54 HIV false-positive and HIV-negative serum samples from 100 hospitalized patients and 600 healthy subjects were included. Results: Compared to the EHIV assay, the CHIV assay had a shorter window for three of the seroconversion panels: a difference of 10 days and two bleeds in one panel, and 4 days and one bleed in the other two panels. Only 34 of the 54 (63%) samples known to yield false-positive results by EHIV assay had repeatedly yielded reactive results in the CHIV assay. One of the 600 healthy subjects had a false-positive result with the CHIV assay; thus, the specificity was 99.85% (699/700). CHIV accurately determined the reactive results for the HIV-confirmed serum samples from known HIV patients and Korea Food & Drug Administration (KFDA) panels. Conclusions: The new fourth-generation ADVIA Centaur HIV assay is a sensitive and specific assay that shortens the serological window period and allows early diagnosis of HIV infection.

Abstract

Background: Early diagnosis of HIV infection reduces morbidity and mortality. Fourth-generation HIV detection assays are more sensitive because they can detect p24 antigen as well as anti-HIV antibodies. In this study, we evaluated the performance of a new fourth-generation ADVIA Centaur HIV antigen/antibody combo (CHIV) assay (Siemens Healthcare Diagnostics Inc., USA) for early detection of HIV infection and reduction of false positive rate. Methods: Four seroconversion panels were included. The third-generation ADVIA Centaur HIV 1/O/2 enhanced (EHIV) assay (Siemens Healthcare Diagnostics Inc., USA) and fourth-generation CHIV assay were used to test each panel for HIV infection. The presence of antigen was confirmed using HIV p24 antigen assay. To evaluate false-positivity and specificity, 54 HIV false-positive and HIV-negative serum samples from 100 hospitalized patients and 600 healthy subjects were included. Results: Compared to the EHIV assay, the CHIV assay had a shorter window for three of the seroconversion panels: a difference of 10 days and two bleeds in one panel, and 4 days and one bleed in the other two panels. Only 34 of the 54 (63%) samples known to yield false-positive results by EHIV assay had repeatedly yielded reactive results in the CHIV assay. One of the 600 healthy subjects had a false-positive result with the CHIV assay; thus, the specificity was 99.85% (699/700). CHIV accurately determined the reactive results for the HIV-confirmed serum samples from known HIV patients and Korea Food & Drug Administration (KFDA) panels. Conclusions: The new fourth-generation ADVIA Centaur HIV assay is a sensitive and specific assay that shortens the serological window period and allows early diagnosis of HIV infection.

참고문헌 (22)

  1. UNAIDS, "AIDS epidemic update 2009", pp.2009, UNAIDS
  2. "Analysis of HIV/AIDS Notifications in Korea"[URL]
  3. 이선희, "Trends of Mortality and Cause of Death among HIV-Infected Patients in Korea, 1990-2011", Journal of Korean Medical Science, 28(1), pp.67~73 (2013), 대한의학회
  4. Choe PG, "Late presentation of HIV disease and its associated factors among newly diagnosed patients before and after abolition of a government policy of mass mandatory screening", JOURNAL OF INFECTION, 63, pp.60~65 (2011), W B SAUNDERS CO LTD
  5. Branson BM, "Revised recommendations for HIV testing of adults, adolescents, and pregnant women in health-care settings", MMWR Recomm Rep, 55, pp.1~17 (2006)
  6. Mahajan VS, "Interpretation of HIV serologic testing results", Clin Chem, 56, pp.1523~1526 (2010)
  7. Gürtler L, "Reduction of the diagnostic window with a new combined p24 antigen and human immunodeficiency virus antibody screening assay", J Virol Methods, 75, pp.27~38 (1998)
  8. Busch MP, "Time course of viremia and antibody seroconversion following human immunodeficiency virus exposure", Am J Med, 102, pp.117~124 (1997)
  9. Weber B, "Reduction of diagnostic window by new fourth-generation human immunodeficiency virus screening assays", J Clin Microbiol, 36, pp.2235~2239 (1998)
  10. Brust S, "Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1", 2, J Virol Methods, pp.2000, 90[DOI]
  11. Weber B, "Multicenter evaluation of a new automated fourth-generation human immunodeficiency virus screening assay with a sensitive antigen detection module and high specificity", J Clin Microbiol, 40, pp.1938~1946 (2002)
  12. Beelaert G, "Evaluation of a rapid and simple fourth-generation HIV screening assay for qualitative detection of HIV p24 antigen and", or antibodies to HIV-1 and HIV-2, 2010, pp.168, 218~222
  13. Weber B, "Multicenter evaluation of a new 4th generation HIV screening assay Elecsys HIV combi", Clin Lab, 52, pp.463~473 (2006)
  14. 강희정, "애보트 4세대 HIV 항원", 항체 검사 시약의 평가, 2006, pp.26(1), 39~44[DOI]
  15. Kwon JA, "Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays", J VIROL METHODS, 133(133), pp.20~26 (2006), Elsevier
  16. Butto S, "Laboratory diagnostics for HIV infection", Ann Ist Super Sanita, 46, pp.24~33 (2010)
  17. Song EY, "Performances of four fourth-generation human immunodeficiency virus-1 screening assays", J Med Virol, 84, pp.1884~1888 (2012)
  18. Pumarola T, "Performance evaluation of the ADVIA Centaur(®) HIV Ag", Ab Combo assay, 2010, pp.170, 16~20
  19. Erickson CP, "Influenza vaccination and false positive HIV results", N Engl J Med, 354, pp.1422~1423 (2006)
  20. Chao TT, "Risk factors associated with false positive HIV test results in a low-risk urban obstetric population", J Pregnancy, 2012, pp.841979~ (2012)
  21. Kasper DL, "Harrison’s principles of internal medicine. 18th ed" (2012), McGraw-Hill
  22. Miedouge M, "Analytical sensitivity of four HIV combined antigen", antibody assays using the p24 WHO standard, 2011, pp.50, 57~60

관련 논문AI추천

이 간행물의 다른 논문 (12건)