본문 바로가기
KERD
논문KCI 등재

Performance Evaluation of the Preanalytic Module of the ACL TOP 750 Hemostasis Lab System

0

조회

0

다운로드

0

인용

0

참고문헌

주제분류병리학

초록

Dear Editor, Hemolysis, icterus, and lipemia are important preanalytic sources of errors in coagulation testing of blood samples, besides sample-to-anticoagulant ratio, transport stability, and storage temperature. Lipemia (13%), hyperbilirubinemia (11%), and hemolysis (4%) in whole blood cause errors in coagulation testing [1, 2]. Hemoglobin, bilirubin, and triglyceride are major interfering substances that affect test results by spectral overlap [3, 4]. Hemolytic, icteric, and lipemic (HIL) sample check functions have been implemented in the preanalytic module of the ACL TOP family 50 series spectrophotometric hemostasis equipment (Instrumentation Laboratory Company, Bedford, MA, USA) to support preanalytic sample evaluation. We evaluated the performance of the ACL TOP 750 preanalytic module, using patient samples.

Abstract

Dear Editor, Hemolysis, icterus, and lipemia are important preanalytic sources of errors in coagulation testing of blood samples, besides sample-to-anticoagulant ratio, transport stability, and storage temperature. Lipemia (13%), hyperbilirubinemia (11%), and hemolysis (4%) in whole blood cause errors in coagulation testing [1, 2]. Hemoglobin, bilirubin, and triglyceride are major interfering substances that affect test results by spectral overlap [3, 4]. Hemolytic, icteric, and lipemic (HIL) sample check functions have been implemented in the preanalytic module of the ACL TOP family 50 series spectrophotometric hemostasis equipment (Instrumentation Laboratory Company, Bedford, MA, USA) to support preanalytic sample evaluation. We evaluated the performance of the ACL TOP 750 preanalytic module, using patient samples.

참고문헌 (7)

  1. Salvagno GL, "Prevalence and type of pre-analytical problems for inpatients samples in coagulation laboratory", J Eval Clin Pract, 14, pp.351~353 (2008)[DOI]
  2. Salvagno GL, "Hemolysis, lipaemia and icterus in specimens for arterial blood gas analysis", Clin Biochem, 45, pp.372~373 (2012)[DOI]
  3. Lippi G, "Interference in coagulation testing: focus on spurious hemolysis, icterus, and lipemia", Semin Thromb Hemost, 39, pp.258~266 (2013)
  4. Debra AH, "Hematology: clinical principles and applications", pp.810~828 (2013), Elsevier Health Sciences
  5. Nikolac N, "Lipemia: causes, interference mechanisms, detection and management", Biochem Med (Zagreb), 24, pp.57~67 (2014)
  6. Kroll MH, "Evaluating interference caused by lipemia", Clin Chem, 50, pp.1968~1969 (2004)[DOI]
  7. Twomey P, "Unreliability of triglyceride measurement to predict turbidity induced interference", J Clin Pathol, 56, pp.861~862 (2003)[DOI]

관련 논문AI추천

Development of an Integrated Reporting System for Verifying Hemolysis, Icterus, and Lipemia in Clinical Chemistry Results어영, 김갑성, 김주원, 서동민, 신동훈, 윤갑준, 윤광로, 이만희, 이세일, 장재윤대한진단검사의학회 · Annals of Laboratory Medicine2014 · 제34권 제4호용혈, 황달 및 지질혈증: 자동화 임상화학분석기를 이용한 검사 결과 간섭 평가Jeong Ina, Jun Kyung Ran, Kim Won-Joo, Lee Sun Min, Oh Seung Hwan, Park Chul Min, Yoo Dong-Won대한진단검사의학회 · Laboratory Medicine Online2026 · 제16권 제1호Proposal of Modified HIL-indices for Determining Hemolysis, Icterus and Lipemia Interference on the Beckman Coulter AU5800 Automated Platform임용관, 차영주대한진단검사의학회 · Laboratory Medicine Online2017 · 제7권 제2호Development of a Novel Quality Improvement Indicator Based on the Hemolysis Index강희정, 김미영, 김한성, 박민정, 이영경, 이은진대한진단검사의학회 · Annals of Laboratory Medicine2016 · 제36권 제6호Impact of Individualized Hemolysis Management Based on Biological Variation Cut-offs in a Clinical LaboratoryJung David Hansoe Heredero, Marques-Garcia Fernando, Pérez Sandra Elena대한진단검사의학회 · Annals of Laboratory Medicine2022 · 제42권 제2호Coapresta 2000을 이용한 혈액응고검사의 평가박용정, 송성욱, 송재우, 최종락, 최종현대한진단검사의학회 · Laboratory Medicine Online2011 · 제1권 제2호

이 간행물의 다른 논문 (17건)