ABO-Incompatible Transfusion Events Reported in Written Judgments and in the Korean Hemovigilance System
2
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Fatal ABO-incompatible (ABOi) transfusion is one of the most common causes of transfusion-related death, but its reporting has been limited in Korea. We comprehensively reviewed ABOi transfusion events in Korea by analyzing cases reported in literature, Korean hemovigilance system (KOHEVIS) annual reports, and written judgments. Written judgments were assessed using a written judgment management system or a comprehensive legal information system. We found nine cases of ABOi transfusion events in written judgments (from 1953 to 2019), 16 in the KOHEVIS (from 2008 to 2018), and nine in published reports (from 1978 to 2019). One case was found in all three sources. Overall, we found 32 cases of ABOi transfusion events. Four cases died and 23 survived, while the outcomes for five were unavailable. ABOi transfusion errors occurred at the administration (50%, 16/32), sample (13%, 4/32), and testing (9%, 3/32) stages. The causes of errors were unavailable for nine cases (28%, 9/32). We report the status of ABOi transfusions in Korea and expect our results to contribute to the prevention of adverse reactions due to ABOi transfusion.
Abstract
Fatal ABO-incompatible (ABOi) transfusion is one of the most common causes of transfusion-related death, but its reporting has been limited in Korea. We comprehensively reviewed ABOi transfusion events in Korea by analyzing cases reported in literature, Korean hemovigilance system (KOHEVIS) annual reports, and written judgments. Written judgments were assessed using a written judgment management system or a comprehensive legal information system. We found nine cases of ABOi transfusion events in written judgments (from 1953 to 2019), 16 in the KOHEVIS (from 2008 to 2018), and nine in published reports (from 1978 to 2019). One case was found in all three sources. Overall, we found 32 cases of ABOi transfusion events. Four cases died and 23 survived, while the outcomes for five were unavailable. ABOi transfusion errors occurred at the administration (50%, 16/32), sample (13%, 4/32), and testing (9%, 3/32) stages. The causes of errors were unavailable for nine cases (28%, 9/32). We report the status of ABOi transfusions in Korea and expect our results to contribute to the prevention of adverse reactions due to ABOi transfusion.
참고문헌 (20)
- Sidhu M, "Report on errors in pretransfusion testing from a tertiary care center: a step toward transfusion safety", Asian J Transfus Sci, 10, pp.48~52 (2016)
- Klein HG, "Mollison’s blood transfusion in clinical medicine", pp.460~462 (2014), John Wiley & Sons
- Kim H, "Establishment of the Korean haemovigilance system", ISBT Science Ser, 13, pp.312~316 (2018)
- "Korean hemovigilance annual report"[URL]
- "Written judgment management system"[URL]
- "Comprehensive legal information system"[URL]
- 임현호, "ABO 부적합 수혈에 의한 급성용혈수혈반응: 치명적 증례 보고 및 문헌 검토", 대한수혈학회지, 29(1), pp.73~78 (2018), 대한수혈학회[DOI]
- Kim YL, "A clinical experience upon acute renal failure due to mismatched blood transfusion", Korean J Anesthesiol, 11, pp.49~54 (1978)
- Lim HS, "Experience of treatment in acute hemolytic transfusion reaction following an ABO-incompatible blood transfusion: a case report", Intraven Anesth, 8, pp.186~191 (2004)
- 우철민, "Cis AB 환자에서 나타난 부적합수혈반응", Korean Journal of Anesthesiology, 51(5), pp.632~637 (2006), 대한마취통증의학회
- 천세종, "Cis-AB, the Blood Group of Many Faces, Is a Conundrum to the Novice Eye", Annals of Laboratory Medicine, 39(2), pp.115~120 (2019), 대한진단검사의학회[DOI]
- 김남수, "급성용혈수혈반응 환자에서 혈장교환을 통한 원인 항체의 제거", 대한수혈학회지, 29(1), pp.79~85 (2018), 대한수혈학회[DOI]
- Bolton‐Maggs PHB, "Serious hazards of transfusion–conference report: celebration of 20 years of UK haemovigilance", Transfus Med, 27, pp.393~400 (2017)
- 조덕, "ABO 혈액형 불일치 수혈사고의 예방: ‘2-2-2 안전수혈 캠페인’", 대한수혈학회지, 24(1), pp.79~81 (2013), 대한수혈학회
- 권정란, "Serious Adverse Transfusion Reactions Reported in the National Recipient-Triggered Trace Back System in Korea (2006-2014)", Annals of Laboratory Medicine, 36(4), pp.335~341 (2016), 대한진단검사의학회
- Craig A, "The need for greater reporting of medical device incidents", EMJ Innov, 3, pp.56~63 (2019)
- Mistry H, "Human errors in manual techniques for ABO", D grouping are associated with potentially lethal outcomes, 2019, pp.29, 262~267
- "Blood type mismatch transfusion accident due to Red Cross error"[URL]
- "An absurd transfusion accident at an university hospital... type B blood to type O patient"[URL]
- Dzik WH, "New technology for transfusion safety", Br. J. Haematol, 136, pp.181~190 (2007)