본문 바로가기
KERD
논문KCI 등재

Standardization of ABO Antibody Titer Measurement at Laboratories in Korea

1

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: Measurement of the ABO antibody (Ab) titer is important in ABO-incompati- ble transplantation. However, to the best of our knowledge, no standard protocol or exter- nal survey program to measure the ABO Ab titer has been established in Korea. We inves- tigated the current status of ABO Ab titer measurements at various laboratories in Korea and the impact of the protocol provided to reduce interlaboratory variations in the meth- ods and results of ABO Ab titers. Methods: The Korean external quality assessment of blood bank laboratories sent external survey samples with a questionnaire to 68 laboratories across Korea for the measurement of ABO Ab titers in May 2012. After 6 months, a second set of survey samples were sent with a standard protocol to 53 of the previously surveyed laboratories. The protocol recom- mended incubation at room temperature only and use of the indirect antihuman globulin method for the tube test as well as and the column agglutination test (CAT). Results: Several interlaboratory variations were observed in the results, technical proce- dures, and methods selected for measurement. We found that 80.4% laboratories hoped to change their protocol to the provisional one. Additionally, CAT showed significantly lower variation among laboratories ( P =0.006) than the tube test. Conclusions: Our study provides baseline data regarding the current status of ABO Ab ti- ter measurement in Korea. The standard protocol and external survey were helpful to standardize the technical procedures and select methods for ABO Ab titer measurement.

Abstract

Background: Measurement of the ABO antibody (Ab) titer is important in ABO-incompati- ble transplantation. However, to the best of our knowledge, no standard protocol or exter- nal survey program to measure the ABO Ab titer has been established in Korea. We inves- tigated the current status of ABO Ab titer measurements at various laboratories in Korea and the impact of the protocol provided to reduce interlaboratory variations in the meth- ods and results of ABO Ab titers. Methods: The Korean external quality assessment of blood bank laboratories sent external survey samples with a questionnaire to 68 laboratories across Korea for the measurement of ABO Ab titers in May 2012. After 6 months, a second set of survey samples were sent with a standard protocol to 53 of the previously surveyed laboratories. The protocol recom- mended incubation at room temperature only and use of the indirect antihuman globulin method for the tube test as well as and the column agglutination test (CAT). Results: Several interlaboratory variations were observed in the results, technical proce- dures, and methods selected for measurement. We found that 80.4% laboratories hoped to change their protocol to the provisional one. Additionally, CAT showed significantly lower variation among laboratories ( P =0.006) than the tube test. Conclusions: Our study provides baseline data regarding the current status of ABO Ab ti- ter measurement in Korea. The standard protocol and external survey were helpful to standardize the technical procedures and select methods for ABO Ab titer measurement.

참고문헌 (12)

  1. Alexandre GP, "Splenectomy as a prerequisite for successful human ABO-incompatible renal-transplantation", Transplant Proc, 17, pp.138~143 (1985)
  2. Chang CL, "A single center experience of ABO incompatible kidney transplantation", J Korean Soc Transplant, 26, pp.261~268 (2012)
  3. Tobian AA, "ABO antibody titer monitoring for incompatible renal transplantation", Transfusion, 51, pp.454~457 (2011)
  4. Kobayashi T, "A series of surveys on assay for anti-A", B antibody by Japanese ABO-incompatible Transplantation Committee, 2006, pp.13, 136~140
  5. AuBuchon JP, "Reducing the variation in performance of antibody titrations", Vox Sang, 95, pp.57~65 (2008)
  6. 이은영, "국내 4개 대학병원에서의 ABO 항체역가 검사의 현황조사", 대한수혈학회지, 22(1), pp.24~30 (2011), 대한수혈학회
  7. Roback JD, "Technical manual. 17th ed", pp.369~ (2011), American Association of Blood Banks
  8. Roback JD, "Technical manual. 17th ed", pp.907~910 (2011), American Association of Blood Banks
  9. Roback JD, "Technical manual. 17th ed", pp.935~937 (2011), American Association of Blood Banks
  10. 강민구, "시험관법을 이용한 검사법에 따른 ABO 동종 응집소 역가 비교", 대한수혈학회지, 20(3), pp.227~234 (2009), 대한수혈학회
  11. Tobian AA, "The critical role of plasmapheresis in ABO-incompatible renal transplantation", Transfusion, 48, pp.2453~2460 (2008)
  12. Kumlien G, "Comparing the tube and gel techniques for ABO antibody titration, as performed in three European centers", Transplantation, 84(12), pp.17~19 (2007)

관련 논문AI추천

ABO Antibody Titer Testing Harmonization in Korea: A 5-Year Analysis of External Quality Control DataChung Yousun, Hwang Sang-Hyun, Kim Han Joo, Kim Hyungsuk, Ko Dae-Hyun, Oh Heung-Bum대한진단검사의학회 · Annals of Laboratory Medicine2025 · 제45권 제3호ABO 동종 응집소 역가 측정을 위한 시험관 및 미세원주응집법의 평가김영기, 김장수, 김하늬, 윤승규, 이갑노, 임채승, 조치현, 최계령, 최재열대한진단검사의학회 · Laboratory Medicine Online2011 · 제1권 제1호Comparison of Total and IgG ABO Antibody Titers in Healthy Individuals by Using Tube and Column Agglutination Techniques박노진, 박은수, 방해인, 신정원, 윤순규, 조경일, 채금란, 최태윤대한진단검사의학회 · Annals of Laboratory Medicine2014 · 제34권 제3호Comparison of ABO Antibody Titers on the Basis of the Antibody Detection Method Used강선주, 백새윤, 임영애대한진단검사의학회 · Annals of Laboratory Medicine2014 · 제34권 제4호Choice of ABO Group for Blood Component Transfusion in ABO-Incompatible Solid Organ Transplantation: A Questionnaire Survey in Korea and Guideline Proposal고대현, Chung Yousun, Kim Hyungsuk, Kim Kyeong-Hee, Lim Jihyang대한진단검사의학회 · Annals of Laboratory Medicine2022 · 제42권 제1호Development of Cryopreserved Red Blood Cell Panels as Biological Reference Standards for Performance Evaluation of ABO and D Blood Grouping Reagents고대현, 김신영, 김현옥, 임지향, 조윤경, 최승준대한진단검사의학회 · Laboratory Medicine Online2022 · 제12권 제1호

이 간행물의 다른 논문 (14건)