논문KCI 등재
Intraocular Lens Power Calculation Using IOLMaster and Various Formulas in Short Eyes
대한안과학회 (The Korean Ophthalmological Society)|2011.06|Korean Journal of Ophthalmology|제25권 제3호|pp. 151-155
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
주제분류안과학
초록
Intraocular Lens Power Calculation Using IOLMaster and Various Formulas in Short Eyes
Abstract
Intraocular Lens Power Calculation Using IOLMaster and Various Formulas in Short Eyes
참고문헌 (18)
- Kershner RM, "Sutureless one-handed intercapsular phacoemulsification. The keyhole technique", J Cataract Refract Surg, 17(Suppl), pp.719~725 (1991)
- Olsen T, "Evaluating surgically induced astigmatism by Fourier analysis of corneal topography data", J Cataract Refract Surg, 22, pp.318~323 (1996)
- Olson RJ, "Prospective randomized comparison of phacoemulsification cataract surgery with a 3.2-mm vs a 5.5-mm sutureless incision", Am J Ophthalmol, 125, pp.612~620 (1998)
- Kohnen T, "Multifocal IOL technology:a successful step on the journey toward presbyopia treatment", J Cataract Refract Surg, 34, pp.2005~ (2008)
- Lee AC, "Biometry and intraocular lens power calculation", Curr Opin Ophthalmol, 19, pp.13~17 (2008)
- Drexler W, "Partial coherence interferometry:a novel approach to biometry in cataract surgery", Am J Ophthalmol, 126, pp.524~534 (1998)
- Holladay JT, "Refractive power calculations for intraocular lenses in the phakic eye", Am J Ophthalmol, 116, pp.63~66 (1993)
- Olsen T, "Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster", Acta Ophthalmol Scand, 85, pp.84~87 (2007)
- Wang JK, "Intraocular lens power calculation using the IOLMaster and various formulas in eyes with long axial length", J Cataract Refract Surg, 34, pp.262~267 (2008)
- MacLaren RE, "Biometry and formula accuracy with intraocular lenses used for cataract surgery in extreme hyperopia", Am J Ophthalmol, 143, pp.920~931 (2007)
- Findl O, "High precision biometry of pseudophakic eyes using partial coherence interferometry", J Cataract Refract Surg, 24, pp.1087~1093 (1998)
- Schachar RA, "Accuracy of intraocular lens powers calculated from A-scan biometry with the Echo-Oculometer", Ophthalmic Surg, 11, pp.856~858 (1980)
- Connors R 3rd, "Accuracy and reproducibility of biometry using partial coherence interferometry", J Cataract Refract Surg, 28, pp.235~238 (2002)
- Gavin EA, "Intraocular lens power calculation in short eyes", Eye(Lond), 22, pp.935~938 (2008)
- Terzi E, "Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia", J Cataract Refract Surg, 35, pp.1181~1189 (2009)
- Chen MJ, "Relationship between central corneal thickness,refractive error,corneal curvature,anterior chamber depth and axial length", J Chin Med Assoc, 72, pp.133~137 (2009)
- Olsen T, "Calculation of intraocular lens power:a review", Acta Ophthalmol Scand, 85, pp.472~485 (2007)
- 김성모, "Refractive Predictability of Partial Coherence Interferometry and Factors that can Affect It", Korean Journal of Ophthalmology, 23(1), pp.6~12 (2009), 대한안과학회
관련 논문AI추천
Intraocular Lens Power Calculation after Refractive Surgery: A Comparative Analysis of Accuracy and Predictability강병수, 김미금, 오주연, 위원량, 한정모대한안과학회 · Korean Journal of Ophthalmology2017 · 제31권 제6호Comparison of Accuracy of Six Modern Intraocular Lens Power Calculation FormulasJi Hyun Yoon, Woong-Joo Whang대한안과학회 · Korean Journal of Ophthalmology2023 · 제37권 제5호Comparative Efficacy of the New Optical Biometer on Intraocular Lens Power Calculation (AL-Scan versus IOLMaster)김미금, 위원량, 하아늘대한안과학회 · Korean Journal of Ophthalmology2018 · 제32권 제3호Accuracy of Intraocular Lens Power Calculation Formulas in Primary Angle Closure Glaucoma김현승, 문정일, Jongsoo Joo, Kyu-Dong Kang, Tae-Hoon Oh, Woong-Ju Whang대한안과학회 · Korean Journal of Ophthalmology2011 · 제25권 제6호Accuracy of the Kane Formula for Intraocular Lens Power Calculation in Comparison with Existing Formulas: A Retrospective Review김응권, 김태임, 류소영, 서경률, 전익현연세대학교의과대학 · Yonsei Medical Journal2021 · 제62권 제12호안축장이 짧은 안에서 인공수정체도수 산출 공식과 전방 깊이에 따른 정확성 분석이영은, 전루민, 최규룡대한안과학회 · 대한안과학회지2010 · 제51권 제10호
이 간행물의 다른 논문 (14건)
Comparison of the Short-Term Effects of Intravitreal Triamcinolone Acetonide and Bevacizumab Injection for Diabetic Macular Edema이상준, Jung Joo Lee, Ju Hwan Songpp. 156-160Multifocal Electroretinogram Findings after Intravitreal Bevacizumab Injection in Choroidal Neovascularization of Age-Related Macular DegenerationSeung Hoon Kim, 온영훈, Joo Youn Park, 박태관pp. 161-165Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCTByung Joo Cho, 신현진pp. 166-173Quantitative Analysis of Optic Disc ColorHwang Ki Kim, Sun Jung Kim, 손용호, 김응수, Seung-Hee Baekpp. 174-177Comparison of Fibrin Glue and Sutures for Conjunctival Wound Closure in Strabismus SurgeryJae Hyung Lee, 강남여pp. 178-184
