초록

In this paper, a heat exchange system using cooling dehumidification and mixing process was proposed as an experimental study for a white smoke reduction heat exchanger system under winter condition. The white smoke reduction heat exchange system is divided into an EA part, SA part, W part and mixing zone. For the operating conditions, three types (Cases 1, 2, and 3) were selected depending on whether EA fan, SA fan, and A-W heat exchanger were operated. In addition, in order to visualize the white smoke exhausted from the mixing zone, it was photographed using CCTV. In order to investigate the performance of the white smoke reduction heat exchange system, the temperature reduction rate and absolute humidity reduction rate of EA and the heat recovery rate of W were calculated. The temperature change of EA and SA according to operating conditions was most effective in Case 3, and the temperature and absolute humidity at the outlet of the mixing zone were greatly reduced. From the results of the white smoke visualization, it was confirmed that the white smoke generation mechanism was different depending on the operating conditions, and the amount of white smoke generation was greatly reduced.

Abstract

In this paper, a heat exchange system using cooling dehumidification and mixing process was proposed as an experimental study for a white smoke reduction heat exchanger system under winter condition. The white smoke reduction heat exchange system is divided into an EA part, SA part, W part and mixing zone. For the operating conditions, three types (Cases 1, 2, and 3) were selected depending on whether EA fan, SA fan, and A-W heat exchanger were operated. In addition, in order to visualize the white smoke exhausted from the mixing zone, it was photographed using CCTV. In order to investigate the performance of the white smoke reduction heat exchange system, the temperature reduction rate and absolute humidity reduction rate of EA and the heat recovery rate of W were calculated. The temperature change of EA and SA according to operating conditions was most effective in Case 3, and the temperature and absolute humidity at the outlet of the mixing zone were greatly reduced. From the results of the white smoke visualization, it was confirmed that the white smoke generation mechanism was different depending on the operating conditions, and the amount of white smoke generation was greatly reduced.

참고문헌 (7)

  1. J, Deng, "Analysis on the causes and prevention measures of white mist in wet flue gas desulfurization", Chemical Engineering of Oil & Gas, 46(2), pp.17~21 (2017)
  2. S. Y. Jeong, "An experimental study on the cooling tower plume prevention optimal design and performance improvements", Proceeding of the KSME Winter Annual Conference, pp, pp.3705~3708 (2015)
  3. 왕쩐후안, "파형 열교환기의 열전달 및 유동특성에 관한 전산해석 연구", 한국기계기술학회지, 19(4), pp.452~457 (2017), 한국기계기술학회[DOI]
  4. 왕쩐후안, "파형 열교환기 피치에 따른 공기측 열전달 성능에 대한 실험적 연구", 한국기계기술학회지, 19(6), pp.821~826 (2017), 한국기계기술학회[DOI]
  5. 왕쩐후안, "동절기 환경조건에서 파형 열교환기 배열에 따른 공기측 열전달 특성에 관한 연구", 한국기계기술학회지, 20(1), pp.62~67 (2018), 한국기계기술학회[DOI]
  6. H, Zhang, "Simulation and experimental analysis on dehumidification and white smoke removal of coal-fired flue gas in falling-film plate used in WESP", CIESC Journal, 72(4), pp.2249~2257 (2021)
  7. Cooling Technology Institute, "Acceptance Test Procedure for Wet-Dry Plume Abatement Cooling Towers, ATC-150", ~ (2011)