파형 열교환기 피치에 따른 공기측 열전달 성능에 대한 실험적 연구
Experimental Study on Air-side Heat Transfer Performance by Pitch of Wave Heat Exchanger
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
In this study, the performance of a small - sized wave heat exchanger to be applied to the white smoke reduction system was experimentally confirmed. The heat transfer rate, drain and pressure drop were measured according to the air flow rate, water flow rate and relative humidity change of the wave heat exchanger for two kinds of pitch numbers. A constant temperature and humidity calorimeter and a constant temperature water bath were used to measure the performance of the wave heat exchanger. The heat transfer rate and drain increased gradually with changes of water flow rate. Case 2 showed more than 50% higher heat transfer rate and drain than Case 1. The increase of air heat transfer rate and drain according to air flow rate was greatly increased when the number of pitches was the same or increased, unlike the result of water flow rate change. In the temperature visualization using a thermal imaging camera, it can be seen that as the water flow rate and the number of pitches increase, the heat transfer becomes more effective in Case 2.
Abstract
In this study, the performance of a small - sized wave heat exchanger to be applied to the white smoke reduction system was experimentally confirmed. The heat transfer rate, drain and pressure drop were measured according to the air flow rate, water flow rate and relative humidity change of the wave heat exchanger for two kinds of pitch numbers. A constant temperature and humidity calorimeter and a constant temperature water bath were used to measure the performance of the wave heat exchanger. The heat transfer rate and drain increased gradually with changes of water flow rate. Case 2 showed more than 50% higher heat transfer rate and drain than Case 1. The increase of air heat transfer rate and drain according to air flow rate was greatly increased when the number of pitches was the same or increased, unlike the result of water flow rate change. In the temperature visualization using a thermal imaging camera, it can be seen that as the water flow rate and the number of pitches increase, the heat transfer becomes more effective in Case 2.
참고문헌 (8)
- Buss, J. R., "Control of fog from cooling towers", Cooling Tower Institute Annual Meeting, ~ (1967)
- Campbell, J. C., "The prevention of fog from cooling towers", Annual Meeting of the Cooling Tower Institute (1976)
- Oh, Y. H., "Experimental study on white plume reduction system using corrugated plate heat exchanger", Korean J. Air-Cond. and Ref. Eng, pp.188~191
- 김병조, "건식 열교환기를 이용한 백연방지 냉각탑 성능의 수치해석적 연구", 설비공학 논문집, 15(12), pp.1018~1027 (2003), 대한설비공학회
- 김민성, "단일굴곡 및 이중굴곡 판 형상을 갖는 직교류 공랭식 판형열교환기의 전열특성에 대한 실험적 연구", 설비공학 논문집, 21(6), pp.347~354 (2009), 대한설비공학회
- 왕쩐후안, "파형 열교환기의 열전달 및 유동특성에 관한 전산해석 연구", 한국기계기술학회지, 19(4), pp.452~457 (2017), 한국기계기술학회[DOI]
- 차선환, "자동차용 루버핀 열교환기의 열전달 및 유동 특성에 관한 수치해석", 한국기계기술학회지, 18(1), pp.18~23 (2016), 한국기계기술학회[DOI]
- 금국빈, "열교환기의 관 배열방식에 의한 열전달특성", 한국기계기술학회지, 18(4), pp.556~562 (2016), 한국기계기술학회[DOI]