The cooling operating characteristics of the 3 room air conditioner are experimentally investigated for the number of the indoor units (A, B, C) and the operating conditions (standard, overload) under the coolingoperation. The cooling capacity and COP were calculated using a multi-type calorimeter. Also, EEV opening, compressor frequency, and superheat degree were obtained when the compressor started. From the experimental results, we can see that the performance and operation characteristics of the air conditioner depend on theindoor unit operation method. In case of simultaneous and single operation, the cooling overload performance was measured lower than the standard condition. Also, in the overload operation, the power consumption of the compressor was greatly increased and the COP was also decreased.

Abstract

The cooling operating characteristics of the 3 room air conditioner are experimentally investigated for the number of the indoor units (A, B, C) and the operating conditions (standard, overload) under the coolingoperation. The cooling capacity and COP were calculated using a multi-type calorimeter. Also, EEV opening, compressor frequency, and superheat degree were obtained when the compressor started. From the experimental results, we can see that the performance and operation characteristics of the air conditioner depend on theindoor unit operation method. In case of simultaneous and single operation, the cooling overload performance was measured lower than the standard condition. Also, in the overload operation, the power consumption of the compressor was greatly increased and the COP was also decreased.

참고문헌 (6)

  1. Y. H. Jun, "Cooling and heating characteristics of system A", C using the digital scroll compressor, 2003, 1536~1541
  2. T. H. Kim, "Multi-air conditioning cycle simulation development for performance and reliability prediction", Proceeding of KSME Spring Conference, pp.27~30 (2012)
  3. C. J. Um, "The capacity and energy efficiency simulation of system air conditioner under the load variation", Proceedings of the SAREK Summer Conference, pp.265~268 (2015)
  4. C. J. Maeng, "Experimental study on the performance characteristics of mobile air-conditioning system with multievaporator", Proceeding of KSAE Spring Conference, pp.334~339 (2015)
  5. T. H. Kim, "Developed simulation tool of system multi-air conditioner with module outdoor units and high-head conditions", Proceedings of the SAREK Summer Conference, pp.36~39 (2014)
  6. "KS C 9306, Air-Conditioner, Korean Agency for Technology and Standard", ~ (1999)