멀티 히트펌프의 냉방저온 운전특성에 대한 실험적 연구

Experimental Study on Operating Characteristics for Cooling Low Temperature Condition of Multi-H/P

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기계공학

초록

In the present study, the experimental study was conducted using a multi-calorie meter, to investigate the cooling performance and cycle operation changes of the multi-heat pump (3 indoor units) for the low outside temperature in summer. The test temperature condition was the low cooling temperature, and the normal performance and dynamic behavior of 3 rooms, 2 rooms, and 1 room were measured to understand the operating characteristics of seven 7 indoor unit combinations. As a result of the experiment, the cooling capacity and COP of the multi-heat pump at low cooling temperature were about 10% and 6% higher than those of the cooling standard temperature. In addition, the dynamic behavior of the indoor units of 3 and 2 rooms was observed differently due to the load difference according to the indoor unit combinations and the non-uniformity of the refrigerant amount. And, when starting the heat pump, the compressor had a maximum peak value and stabilized by repeating the decrease and increase for each indoor unit combination.

Abstract

In the present study, the experimental study was conducted using a multi-calorie meter, to investigate the cooling performance and cycle operation changes of the multi-heat pump (3 indoor units) for the low outside temperature in summer. The test temperature condition was the low cooling temperature, and the normal performance and dynamic behavior of 3 rooms, 2 rooms, and 1 room were measured to understand the operating characteristics of seven 7 indoor unit combinations. As a result of the experiment, the cooling capacity and COP of the multi-heat pump at low cooling temperature were about 10% and 6% higher than those of the cooling standard temperature. In addition, the dynamic behavior of the indoor units of 3 and 2 rooms was observed differently due to the load difference according to the indoor unit combinations and the non-uniformity of the refrigerant amount. And, when starting the heat pump, the compressor had a maximum peak value and stabilized by repeating the decrease and increase for each indoor unit combination.

참고문헌 (6)

  1. 왕은석, "120℃ 스팀 생성을 위한 100 kW급 히트펌프의 실험적 연구", 설비공학 논문집, 30(2), pp.100~106 (2018), 대한설비공학회[DOI]
  2. 김동준, "부하 대응 제어방식을 적용한 축열식 히트펌프시스템의 성능 해석", 설비공학 논문집, 30(3), pp.130~142 (2018), 대한설비공학회[DOI]
  3. 최재웅, "전동식 스크롤 압축기의 축 방향 순응 기능 향상에 대한 연구", 설비공학 논문집, 30(12), pp.576~585 (2018), 대한설비공학회[DOI]
  4. 양동학, "멀티 에어컨의 2실 동시운전 시 냉방성능 특성에 대한 실험적 연구", 한국기계기술학회지, 20(5), pp.612~617 (2018), 한국기계기술학회[DOI]
  5. 권영철, "냉방표준 운전조건에서 멀티 히트펌프의 동시운전 동적특성에 대한 실험연구", 한국기계기술학회지, 24(4), pp.659~664 (2022), 한국기계기술학회[DOI]
  6. "KS C 9306, Air-conditioner", Korean Agency for Technology and Standard, ~ (2017)

관련 논문AI추천

이 간행물의 다른 논문 (33건)