철근콘크리트 골조와 강재댐퍼의 강성비 및 내력비에 따른 내진보강 성능
Performance of Seismic Retrofit According to the Stiffness and Strength Ratios of Steel Damper to Reinforced Concrete Frame
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
The purpose of this study is to evaluate the effectiveness of the seismic retrofit performance for a reinforced concrete structure with steel damper. The nonlinear static analysis of the RC frame specimens with and without retrofit using the steel damper was conducted and the reliability of the analysis was verified by comparing the analysis and test results. Using this analysis model and method, additional nonlinear analysis was conducted considering varying stiffness and strength ratios between RC frame and steel damper and the failure mode of RC frame. As the result of the study, the total absorbed energy increased and the damage of RC frame was reduced as stiffness and strength ratios increased. The seismic retrofit performance, evaluated by means of the yield strength, increasing ratio of the absorbed energy and damage of the frame, increased linear proportionally with the increase of the strength ratio. In addition, the seismic retrofit performance was stable for stiffness ratios larger than 4~5. The energy absorption capacity of the frame governed by shear failure was better than that of the frame governed by flexure failure.
Abstract
The purpose of this study is to evaluate the effectiveness of the seismic retrofit performance for a reinforced concrete structure with steel damper. The nonlinear static analysis of the RC frame specimens with and without retrofit using the steel damper was conducted and the reliability of the analysis was verified by comparing the analysis and test results. Using this analysis model and method, additional nonlinear analysis was conducted considering varying stiffness and strength ratios between RC frame and steel damper and the failure mode of RC frame. As the result of the study, the total absorbed energy increased and the damage of RC frame was reduced as stiffness and strength ratios increased. The seismic retrofit performance, evaluated by means of the yield strength, increasing ratio of the absorbed energy and damage of the frame, increased linear proportionally with the increase of the strength ratio. In addition, the seismic retrofit performance was stable for stiffness ratios larger than 4~5. The energy absorption capacity of the frame governed by shear failure was better than that of the frame governed by flexure failure.
참고문헌 (15)
- L’aquila Italy Earthquake Field Investigation Report, "Miyamoto", Global Risk Miyamoto, ~ (2009)
- Sichuan China Earthquake Field Investigation Report, "Miyamoto", Global Risk Miyamoto, ~ (2008)
- Stavridis A, "Shaked-table tests of a three-story reinforced concrete frame with masonry infill walls", Earthquake Engineering & Structural Dynamics, 41(6), pp.1089~1108 (2012)
- Alqatamin A, "The action of short columns at reinforced concrete building constructions", Bulletin of th Transilvania University of Brasov, 2, pp.357~360 (2009)
- Vahidi EK, "Conceptual Investigation of shortcolumns and masonry infill frames effect in the earthquakes", World Academy of Science Engineering and Technology, 59, pp.119~124 (2009)
- Management Agency. Development of technologies for improvement of seismic performance on the existing low-rise buildings, "National Emergency Management Agency", National Emergency Management Agency, ~ (2011)
- 이상호, "철근콘크리트 골조의 내진성능 향상을 위한 강재댐퍼시스템의 제안", 대한건축학회논문집 구조계, 27(09), pp.21~28 (2011), 대한건축학회
- 오상훈, "슬릿플레이트 댐퍼를 가진 기둥-보 접합부 이력거동", 대한건축학회논문집 구조계, 21(12), pp.101~108 (2005), 대한건축학회
- 오상훈, "강재를 이용한 조립 및 접착이 가능한 내진보강에 관한 연구", 대한건축학회논문집 구조계, 21(11), pp.51~58 (2005), 대한건축학회
- Kang Ninig Li., "CANNY manual", ~ (2009)
- Oh SH, "Seismic design of energy dissipating multi-story frame with flexible-stiff mixed type connection", 박사, pp.1998
- Architectural Institute of Korea, "Korean Building Code and Commentary", Architectural Institute of Korea, ~ (2009)
- Arima Momoko, "Evaluation for the displacement of R", C columns in bending failure with spandrel wall, 2008, pp.30(3), 205~210
- Architectural Institute of Japan, "AIJ standard for structural calculation of reinforced concrete structures", Architectural Institute of Japan, ~ (2010)
- The Japan Building Disaster Prevention Association, "Seismic Retrofit Applications of Existing Reinforced Concrete Buildings and many others", ~ (2001)