The WUF-W moment connection is a pre-qualified connection that can be used for special moment frames specified in current seismic design specifications. Since the stress distribution near the connection varies according to access hole configuration, the cyclic performance of WUF-W connections is strongly affected by the access hole configurations. To evaluate the connection performance according to various access hole configurations, it is expensive to conduct experiments with many connection specimens. Instead, finite element analyses (FEA) can be performed. Throughout the FEA, stress and strain distribution in the connection can be monitored at each loading step. The purpose of this study is to construct nonlinear 3-dimensional FE models for accurately predicting the cyclic behavior of WUF-W connections. For predicting connection fracture using FEA, an appropriate response index detecting the incidence of connection rupture is proposed.

Abstract

The WUF-W moment connection is a pre-qualified connection that can be used for special moment frames specified in current seismic design specifications. Since the stress distribution near the connection varies according to access hole configuration, the cyclic performance of WUF-W connections is strongly affected by the access hole configurations. To evaluate the connection performance according to various access hole configurations, it is expensive to conduct experiments with many connection specimens. Instead, finite element analyses (FEA) can be performed. Throughout the FEA, stress and strain distribution in the connection can be monitored at each loading step. The purpose of this study is to construct nonlinear 3-dimensional FE models for accurately predicting the cyclic behavior of WUF-W connections. For predicting connection fracture using FEA, an appropriate response index detecting the incidence of connection rupture is proposed.

참고문헌 (22)

  1. A Survey of Steel Moment-Resisting Frame Buildings Affected By the 1994 Northridge Earthquake, "Youssef NF", National Technical Information Service, ~, pp.Rep. No. NISTIR 5625 (1995)
  2. Stojadinovic B, "Parametric Tests on Unreinforced Steel Moment Connections", J. Struct. Eng, 126(1), pp.40~49 (2000)
  3. SAC Joint Venture, "Recommended seismic design criteria for new steel moment frame buildings. FEMA 350", ~ (2000)
  4. Development and evaluation of improved details for ductile welded unreinforced flange connection, "Ricles JM", SAC Joint Venture, ~, pp.Rep. No. SAC (2000), BD-00[DOI]
  5. Lee D, "Cyclic connections reinforced by alternative column stiffner details Ⅰ: panel zone behavior and doubler plate detailing", Engineering Journal, 42(4), pp.189~214 (2005), AISC
  6. Lee D, "Cyclic connections reinforced by alternative column stiffner details Ⅱ: panel zone behavior and doubler plate detailing", Engineering Journal, 42(4), pp.215~238 (2005), AISC
  7. American Institute of Steel Construction, "Prequalified connections for special and intermediate steel moment frames for seismic applications. AISC", AISC 358-10, 2010
  8. 황성훈, "WUF-W 모멘트 접합부의 비탄성 반복 하중 실험", 대한건축학회논문집 구조계, 26(10), pp.61~68 (2010), 대한건축학회
  9. 한상환, "개선된 엑세스 홀 형상을 갖는 WUF-W접합부의 실험 을 통한 내진성능평가", 한국지진공학회논문집, 16(6), pp.21~28 (2012), 한국지진공학회
  10. American Welding Society, "Structural Welding Code-Seismic Supplement. AWS D1.8", D1.8M, 2009
  11. Ricles JM, "Development of improved welded moment connections for earthquake-resistant design", Journal of Structural Engineering, 58(19), pp.565~604 (2002), ASCE
  12. Ricles JM, "Inelastic cyclic testing of welded unreinforced moment connections", Journal of Structural Engineering, 128(4), pp.429~440 (2002), ASCE
  13. Mao C, "Effect of local details on ductility of welded moment connections", Journal of Structural Engineering, 127(9), pp.1036~1044 (2001), ASCE
  14. American Institute of Steel Construction, "Seismic Provisions for Structural Steel Buildings. AISC", AISC 341-10, 2010
  15. Dassault Systemes, "ABAQUS Analysis User’s Manual", ~ (2010)
  16. Strength and Ductility of FR Welded-Bolted Connections, "El-Tawil S", SAC Joint Venture, ~, pp.Rep. No. SAC (1998), BD-98[DOI]
  17. Chaboche JL, "Time-independent constitutive theories for cyclic plasticity", International Journal of Plasticity, 2(2), pp.149~188 (1986)
  18. Characterization of cyclic inelastic strain behavior on properties of A572 Gr.50 and A913 Gr. 50 Rolled Sections, "Kaufmann EJ", ~, pp.ATLSS Rep. No. 01-13 (2001)
  19. Atashzaban A, "Optimum drilled flange moment resisting connections for seismic regions", J. Constr. Steel. Res, 112, pp.325~338 (2015)
  20. Lemaitre J, "Reinitiation of a crack reaching an interface", International Journal of Fracture, 80(4), pp.257~276 (1996)
  21. Hancock JW, "On the mechanisms of ductile failure in high-strength steels subjected to multi-axial stress-states", J. Mech. Phys. Solids, 24(2), pp.147~160 (1976)
  22. Lu LW, "Critical issues in achieving ductile behavior of welded moment connections", Journal of Constructional Steel Research, 55, pp.325~341 (2000)