초록

The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.

Abstract

The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.

참고문헌 (12)

  1. ASCE, "Seismic evaluation and retrofit of existing buildings (41-17)", ~ (2017)
  2. NIST, "Guidelines for nonlinear structural analysis for design of buildings, part IIa steel moment frames, NIST GCR 17-917-46v2", Applied Technology Council for the National Institute of Technology and Standards, ~ (2017)
  3. Lee CH, "Cyclic seismic testing of full-scale column-tree type steel moment connections", Journal of Korean Society of Steel Construction, 10(4), pp.629~639 (1998)
  4. 오근영, "Seismic Performance Evaluation of Korean Column-Tree Steel Moment Connections", International Journal of STEEL STRUCTURES, 16(4), pp.1287~1298 (2016), 한국강구조학회[DOI]
  5. 이경구, "볼트 미끄럼을 고려한 칼럼-트리 형식 철골모멘트 접합부의 회전성능평가", 한국방재학회논문집, 15(1), pp.39~45 (2015), 한국방재학회
  6. "Design criteria for steel structures in buildings (41-31-00)" (2019)[URL]
  7. Kim TW, "Seismic analysis of steel moment frames with column-tree connections", Journal of Constructional Steel Research, 168, pp.105871~ (2020)
  8. "ANSI", AISC 360, Specification for structural Steel Buildings, 2016
  9. Krawinkler H, "Shear in beam-column joints in seismic design of steel frames", Engineering Journal, 15(3) (1978)
  10. Inelastic Behavior of Steel Beam-to-Column Subassemblages, "H. Krawinkler", Earthquake Engineering Research Center, University of California, ~, pp.Report No. EERC-71 (1971), 7
  11. Further Studies on Seismic Behavior of Steel Beam-Column Sub-Assemblages, "V.V. Bertero", Earthquake Engineering Research Center, University of California, ~, pp.Report No. EERC-73 (1973), 27
  12. "open system for earthquake engineering simulation"[URL]

관련 논문AI추천

이 간행물의 다른 논문 (6건)