변위계수법 및 약산식 내진성능평가에 기초한 비보강 조적조 건물의 내진보강 요구강도 산정
Strength Demand Calculation for Retrofitting Unreinforced Masonry Buildings Based on the Displacement Coefficient Method and the Preliminary Seismic Evaluation Procedure
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Based on the nonlinear static analysis and the approximate seismic evaluation method adopted in “Guidelines for seismic performance evaluation for existing buildings, two methods to calculate strength demand for retrofitting individual structural walls in unreinforced masonry buildings are proposed.” The displacement coefficient method to determine displacement demand from nonlinear static analysis results is used for the inverse calculation of overall strength demand required to reduce the displacement demand to a target value meeting the performance objective of the unreinforced masonry building to retrofit. A preliminary seismic evaluation method to screen out vulnerable buildings, of which detailed evaluation is necessary, is utilized to calculate overall strength demand without structural analysis based on the difference between the seismic demand and capacity. A system modification factor is introduced to the preliminary seismic evaluation method to reduce the strength demand considering inelastic deformation. The overall strength demand is distributed to the structural walls to retrofit based on the wall stiffness, including the remaining walls or otherwise. Four detached residential houses are modeled and analyzed using the nonlinear static and preliminary evaluation procedures to examine the proposed method.
Abstract
Based on the nonlinear static analysis and the approximate seismic evaluation method adopted in “Guidelines for seismic performance evaluation for existing buildings, two methods to calculate strength demand for retrofitting individual structural walls in unreinforced masonry buildings are proposed.” The displacement coefficient method to determine displacement demand from nonlinear static analysis results is used for the inverse calculation of overall strength demand required to reduce the displacement demand to a target value meeting the performance objective of the unreinforced masonry building to retrofit. A preliminary seismic evaluation method to screen out vulnerable buildings, of which detailed evaluation is necessary, is utilized to calculate overall strength demand without structural analysis based on the difference between the seismic demand and capacity. A system modification factor is introduced to the preliminary seismic evaluation method to reduce the strength demand considering inelastic deformation. The overall strength demand is distributed to the structural walls to retrofit based on the wall stiffness, including the remaining walls or otherwise. Four detached residential houses are modeled and analyzed using the nonlinear static and preliminary evaluation procedures to examine the proposed method.
참고문헌 (15)
- "FEMA P-774. Unreinforced Masonry Buildings and Earthquakes", FEMA, ~ (2009)
- Dŏgangün A, "Seismic performance of masonry buildings during recent earthqukes in Turkey", Proceedings of the 14th World Conference on Earthquake Engineering (14WCEE), pp.12~17 (2008)
- 김태완, "3단계 절차를 이용한 비보강 조적조 건물의 내진성능평가", 한국지진공학회논문집, 15(3), pp.57~64 (2011), 한국지진공학회
- 설윤정, "외부벽체 강도증진형 보강이 적용된 비보강 조적조 건물의 내진성능평가", 한국지진공학회논문집, 24(2), pp.77~86 (2020), 한국지진공학회[DOI]
- Bae BI, "Evaluation of Shear Strength of Unreinforced Masonry Walls Retrofitted by Fiber Reinforced Polymer Sheet", J of the KCI, 24(3), pp.305~313
- Mustafaraj E, "In-plane shear strengthening of unreinforced masonry walls using GFRP jacketing", Period Polytech Civ Eng, 62, pp.330~336 (2018)
- D’Ambrisi A, "Experimental investigation on polymeric net-RCM reinforced masonry panels", Compos Struct, 105, pp.207~215 (2013)
- Almeida JAPP, "Assessment of overlay masonry strengthening system under in-plane monotonic and cyclic loading using the diagonal tensile test", Constr Build Mater, 94, pp.851~865 (2015)
- Yu JH, "Investigation of Steel Fiber-Reinforced Mortar Overlay for Strengthening Masonry Walls by Prism Tests", Appl Sci, 10, pp.6395~ (2020)
- Ismail N, "Diagonal shear behavior of unreinforced masonry wallettes strengthened using twisted steel bars", Constr Build Mater, 25, pp.4386~4393 (2011)
- Taghdi M, "Seismic retrofitting of lowrise masonry and concrete walls using steel strips", ASCE J Struct Eng, 126, pp.1017~1025 (2000)
- Yang KH, "Cyclic shear behavior of masonry walls strengthened with prestressed steel bars and glass fiber grids", Compos Struct, 238, pp.1~12 (2020)
- Korea Authority of Land & Infrastructure Safety, "Guidelines for seismic performance evaluation for existing buildings. 11-B552016-000035-14", ~ (2021)
- American Society of Civil Engineers, "ASCE 41-17 Seismic Evalution and Retrofitting Techniques for Unreinforced Masonry Buildings", ~ (2017)
- Ministry of Land and Transportation, "Seismic Design in General. KDS 17 10 00" (2019), Korea Construction Standards Center