초록
The use of dampers is being considered a means to improve the seismic performance of buildings. It may take considerable time and effort to find an optimal design solution since repeated three-dimensional nonlinear time history analyses are required. Therefore, a preliminary design procedure for seismic retrofit using hysteretic dampers was proposed in this study. In the proposed procedure, the amount of retrofit (required number of dampers) is estimated from the capacity curve of the building before retrofit and allowable story drift of the building. In combining the capacity curves of the building and the dampers, the deformation demand for the dampers can be easily checked against their deformation capacity. The equations to transform the device displacement to roof displacement for the combination of capacity curves are developed. The proposed procedure was applied to the seismic retrofit design of sample buildings. The study found that the estimated capacity curve was very close to the actual capacity curve obtained from the pushover analysis, which can determine an appropriate configuration to meet the required seismic performance.
Abstract
The use of dampers is being considered a means to improve the seismic performance of buildings. It may take considerable time and effort to find an optimal design solution since repeated three-dimensional nonlinear time history analyses are required. Therefore, a preliminary design procedure for seismic retrofit using hysteretic dampers was proposed in this study. In the proposed procedure, the amount of retrofit (required number of dampers) is estimated from the capacity curve of the building before retrofit and allowable story drift of the building. In combining the capacity curves of the building and the dampers, the deformation demand for the dampers can be easily checked against their deformation capacity. The equations to transform the device displacement to roof displacement for the combination of capacity curves are developed. The proposed procedure was applied to the seismic retrofit design of sample buildings. The study found that the estimated capacity curve was very close to the actual capacity curve obtained from the pushover analysis, which can determine an appropriate configuration to meet the required seismic performance.
참고문헌 (21)
- "KDS 41 17 00. Seismic building design code", KCSC, ~ (2019)
- "ASCE", SEI 7-16. Minimum design loads and associated criteria for buildings and other structures, 2017
- "Seismic Building Design Code and Commentary(KBC)", AIK, ~ (2019)
- Park SE, "Optimum of Damper Position for Steel Frame Structure on Seismic Design", 한국산업융합학회 논문집, 12(4), pp.187~192 (2009), KSIC
- Lee SH, "Preliminary design procedure of Mr dampers for controlling seismic response of building structures", Electrorheological Fluids and Magnetorheological Suspensions (ERMR 2004) (2005), WORLD SCIENTIFIC
- 노지은, "응답스펙트럼을 활용한 감쇠장치 예비 설계절차 제시", 한국지진공학회논문집, 23(2), pp.109~117 (2019), 한국지진공학회[DOI]
- "FEMA356. Federal emergency management agency", FEMA, ~ (2000)
- Go CG, "A linearization model for the Displacement Dependent Semi-active Hydraulic Damper", J Vib Control, 16(14), pp.2195~2214 (2010)
- Connor JJ, "Damage-controlled structures. I: Preliminary design methodology for seismically active regions", J Struct Eng (NY), 123(4), pp.423~431 (1997)
- Kyoung Sun Moon, "Vertically distributed multiple tuned mass dampers in tall buildings: performance analysis and preliminary design", The Structural Design of Tall and Special Buildings (2009), Wiley[DOI]
- Teran-Gilmore A, "Preliminary design of low-rise buildings stiffened with buckling-restrained braces by a displacementbased approach", Earthq Spectra, 25(1), pp.185~211 (2009)
- Liu W, "Simple procedure for preliminary design of structural damper", Proc. 13th World Conference on Earthquake Engineering (2004)
- Kim J, "Performance-based design of added viscous dampers using capacity spectrum method", J Earthq Eng, 7(1), pp.1~24 (2003)
- Xiao Y, "Efficient direct displacement-based seismic design approach for structures with viscoelastic dampers", Structures, 29, pp.1699~1708 (2021)
- "ATC 40. Seismic evaluation and retrofit of concrete buildings", ATC, ~ (1996)
- "ASCE 41-17. Seismic evaluation and retrofit of existing buildings", ASCE, ~ (2017)
- "Guidelines for evaluating seismic performance of existing facilities (buildings)", KISTEC, ~ (2019)
- "Evaluation of seismic performance and reinforcement manuals for school facilities", MOE, ~ (2019)
- "OpenSees 3.3.0. Open System for Earthquake Engineering Simulation"[URL]
- "Scientific Toolkit for OpenSees"[URL]
- "OpenSeesWiki"[URL]