본문 바로가기
KERD
논문KCI 등재

CFT와 합성보로 이루어진 CJS합성구조시스템의 내진성능 실험 연구

Experimental Study of the Seismic Performance of CJS Hybrid Structural Systems Connected to the CFT Column

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류토목공학

초록

In this study, to verify the structural performance of the Composite Joint System (CJS) hybrid structural model, a cyclic load test was performed and evaluated and verified through the test. To verify the structural performance of the CJS hybrid structural systems’ joint and evaluate the seismic performance, four three-dimensional real-size specimens were developed with three internal beam-column specimens and one external beam-column specimen. The three interior column specimens were classified by different methods of joining the upper column and lower column, and the same bonding method as the primary specimen was used for the exterior column. The structural performances in terms of drift, strength, and energy dissipation capacity were analyzed and compared based on the experimental results. From the displacement-based loading experiment, all specimens showed a lateral drift of 4.0% without any significant strength drop and stable energy dissipation capacity.

Abstract

In this study, to verify the structural performance of the Composite Joint System (CJS) hybrid structural model, a cyclic load test was performed and evaluated and verified through the test. To verify the structural performance of the CJS hybrid structural systems’ joint and evaluate the seismic performance, four three-dimensional real-size specimens were developed with three internal beam-column specimens and one external beam-column specimen. The three interior column specimens were classified by different methods of joining the upper column and lower column, and the same bonding method as the primary specimen was used for the exterior column. The structural performances in terms of drift, strength, and energy dissipation capacity were analyzed and compared based on the experimental results. From the displacement-based loading experiment, all specimens showed a lateral drift of 4.0% without any significant strength drop and stable energy dissipation capacity.

참고문헌 (16)

  1. "The World’s Cities in 2018", DESA, United Nations, ~
  2. 박제영, "충전성을 개선한 각형CFT구조의 기둥-보 접합부 구조적 거동", 대한건축학회논문집 구조계, 28(11), pp.107~115 (2012), 대한건축학회
  3. Elremaily A, "Experimental behavior of steel beam to CFT column connections", Journal of Constructional Steel Research, 57(10), pp.1099~1119 (2001)
  4. Shin KJ, "Behavior of welded CFT column to H-beam connections with external stiffeners", Journal of Engineering Structures, 26(13), pp.1877~1887 (2004)
  5. 김선희, "관통형 다이아프램을 갖는 조립형 콘크리트 충전 각형합성기둥-보 접합부의 내진성능", 한국강구조학회 논문집, 26(5), pp.431~439 (2014), 한국강구조학회
  6. Goto Y, "Local Buckling Restraining Behavior of Thin-Walled Circular CFT Columns under Seismic Loads", Journal of Engineering Structures, 140(5) (2014), ASCE
  7. 엄태성, "얇은 절곡단면을 사용한 콘크리트 충전형 합성부재를 위한 관통볼트 단부강판모멘트접합부의 거동", 한국강구조학회 논문집, 32(6), pp.405~416 (2020), 한국강구조학회[DOI]
  8. Sheet IS, "Experimental investigation of CFT column to steel beam connections under cyclic loading", Journal of Constructional Steel Research, 8, pp.167~182 (2013)
  9. 황현종, "600 MPa 휨 철근을 사용한 특수모멘트 골조의 보-기둥 접합부의 내진성능", 콘크리트학회 논문집, 23(5), pp.591~601 (2011), 한국콘크리트학회
  10. 박홍근, "콘크리트피복충전 각형강관 기둥-보 접합부의 주기하중 실험", 한국강구조학회 논문집, 26(1), pp.55~68 (2014), 한국강구조학회
  11. 이창석, "비연성 RC 기둥의 하중-변형 응답 모사를 위한 모델 매개변수 제안", 한국지진공학회논문집, 23(2), pp.119~129 (2019), 한국지진공학회[DOI]
  12. 임우영, "소규모 철골조 노출형 주각부의 반복가력 실험", 한국구조물진단유지관리공학회 논문집, 21(2), pp.34~45 (2017), 한국구조물진단유지관리공학회
  13. 안태상, "전단벽 제진시스템의 반복가력실험", 한국강구조학회 논문집, 25(1), pp.81~92 (2013), 한국강구조학회
  14. 이홍석, "ENTA이력댐퍼의 실험과 유한 요소 해석을 통한 내진 성능 검증", 한국공간구조학회지, 20(1), pp.79~86 (2020), 한국공간구조학회[DOI]
  15. 박병태, "조적채움벽의 내진성능향상을 위한 외부보강법 개발", 한국방재학회논문집, 17(3), pp.11~19 (2017), 한국방재학회[DOI]
  16. 김영주, "중력하중을 받는 SRC기둥-합성보 접합부 실험", 한국강구조학회 논문집, 26(5), pp.441~452 (2014), 한국강구조학회

관련 논문AI추천

이 간행물의 다른 논문 (4건)