Development of a Novel Intraoperative Neuromonitoring System Using a Surface Pressure Sensor to Detect Muscle Movement: A Rabbit Model Study
2
조회
0
다운로드
5
인용
0
참고문헌
키워드
초록
Objectives. False-negative or false-positive responses in intraoperative neuromonitoring (IONM) using electromyography (EMG) in thyroid surgery pose a challenge. Therefore, we developed a novel IONM system that uses a surface pressure sensor instead of EMG to detect muscle twitching. This study aimed to investigate the feasibility and safety of a new IONM system using a piezo-electric surface pressure sensor in an experimental animal model. Methods. We developed the surface pressure sensor by modifying a commercial piezo-electric sensor. We evaluated the stimulus thresholds to detect muscle movement, as well as the amplitude and latency of the EMG and surface pressure sensor in six sciatic nerves of three rabbits, according to the stimulus intensity. Results. The surface pressure sensor detected the muscle movements in response to a 0.1 mA stimulation of all six sciatic nerves. There were no differences in the thresholds of stimulus intensity between the surface pressure sensor and EMG recordings to detect muscle movements. Conclusion. It is possible to measure the change in surface pressure by using a piezo-electric surface pressure sensor instead of EMG to detect muscle movement induced by nerve stimulation. The application of IONM using a piezo-electric surface pressure sensor during surgery is noninvasive, safe, and feasible. Measuring muscle twitching to identify the state of the nerves using the novel IONM system can be an alternative to recording of EMG responses.
Abstract
Objectives. False-negative or false-positive responses in intraoperative neuromonitoring (IONM) using electromyography (EMG) in thyroid surgery pose a challenge. Therefore, we developed a novel IONM system that uses a surface pressure sensor instead of EMG to detect muscle twitching. This study aimed to investigate the feasibility and safety of a new IONM system using a piezo-electric surface pressure sensor in an experimental animal model. Methods. We developed the surface pressure sensor by modifying a commercial piezo-electric sensor. We evaluated the stimulus thresholds to detect muscle movement, as well as the amplitude and latency of the EMG and surface pressure sensor in six sciatic nerves of three rabbits, according to the stimulus intensity. Results. The surface pressure sensor detected the muscle movements in response to a 0.1 mA stimulation of all six sciatic nerves. There were no differences in the thresholds of stimulus intensity between the surface pressure sensor and EMG recordings to detect muscle movements. Conclusion. It is possible to measure the change in surface pressure by using a piezo-electric surface pressure sensor instead of EMG to detect muscle movement induced by nerve stimulation. The application of IONM using a piezo-electric surface pressure sensor during surgery is noninvasive, safe, and feasible. Measuring muscle twitching to identify the state of the nerves using the novel IONM system can be an alternative to recording of EMG responses.
참고문헌 (27)
- Jeannon JP, "Diagnosis of recurrent laryngeal nerve palsy after thyroidectomy : a systematic review", Int J Clin Pract, 63(4), pp.624~629 (2009)
- Lo CY, "A prospective evaluation of recurrent laryngeal nerve paralysis during thyroidectomy", Arch Surg, 135(2), pp.204~207 (2000)
- Chiang FY, "The mechanism of recurrent laryngeal nerve injury during thyroid surgery : the application of intraoperative neuromonitoring", Surgery, 143(6), pp.743~749 (2008)
- Dionigi G, "Recurrent laryngeal nerve injury in video-assisted thyroidectomy : lessons learned from neuromonitoring", Surg Endosc, 26(9), pp.2601~2608 (2012)
- Randolph GW, "Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery : international standards guideline statement", Laryngoscope, 1(Suppl 1), pp.S1~S16 (2011)
- Chiang FY, "Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation", World J Surg, 34(2), pp.223~229 (2010)
- Horne SK, "Prevalence and patterns of intraoperative nerve monitoring for thyroidectomy", Otolaryngol Head Neck Surg, 136(6), pp.952~956 (2007)
- Barczynski M, "Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy", Br J Surg, 96(3), pp.240~246 (2009)
- Dralle H, "Risk factors of paralysis and functional outcome after recurrent laryngeal nerve monitoring in thyroid surgery", Surgery, 136(6), pp.1310~1322 (2004)
- Angelos P, "Ethical and medicolegal issues in neuromonitoring during thyroid and parathyroid surgery : a review of the recent literature", Curr Opin Oncol, 24(1), pp.16~21 (2012)
- Dralle H, "Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery", World J Surg, 32(7), pp.1358~1366 (2008)
- Tsai CJ, "Electromyographic endotracheal tube placement during thyroid surgery in neuromonitoring of recurrent laryngeal nerve", Kaohsiung J Med Sci, 27(3), pp.96~101 (2011)
- Kim HY, "Impact of positional changes in neural monitoring endotracheal tube on amplitude and latency of electromyographic response in monitored thyroid surgery : results from the porcine experiment", Head Neck, 1, pp.E1004~8 (2016)
- Chiang FY, "Comparison of EMG signals recorded by surface electrodes on endotracheal tube and thyroid cartilage during monitored thyroidectomy", Kaohsiung J Med Sci, 33(10), pp.503~509 (2017)
- Higgins TS, "Recurrent laryngeal nerve monitoring versus identification alone on post-thyroidectomy true vocal fold palsy : a meta-analysis", Laryngoscope, 121(5), pp.1009~1017 (2011)
- Barczynski M, "Intraoperative nerve monitoring can reduce prevalence of recurrent laryngeal nerve injury in thyroid reoperations : results of a retrospective cohort study", World J Surg, 38(3), pp.599~606 (2014)
- Yang S, "Systematic review with meta-analysis of intraoperative neuromonitoring during thyroidectomy", Int J Surg, 39, pp.104~113 (2017)
- Sung ES, "Development of a novel detachable magnetic nerve stimulator for intraoperative neuromonitoring", World J Surg, 42(1), pp.137~142 (2018)
- Sung ES, "Development of an attachable endoscopic nerve stimulator for intraoperative neuromonitoring during endoscopic or robotic thyroidectomy", Otolaryngol Head Neck Surg, 158(3), pp.465~468 (2018)
- Shin SC, "Feasibility and safety of nerve stimulator attachment to energy-based devices : a porcine model study", Int J Surg, 48, pp.155~159 (2017)
- Lu IC, "Optimal depth of NIM EMG endotracheal tube for intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroidectomy", World J Surg, 32(9), pp.1935~1939 (2008)
- Meier JD, "Continuous intraoperative facial nerve monitoring in predicting postoperative injury during parotidectomy", Laryngoscope, 116(9), pp.1569~1572 (2006)
- Dulguerov P, "Postparotidectomy facial nerve paralysis : possible etiologic factors and results with routine facial nerve monitoring", Laryngoscope, 109(5), pp.754~762 (1999)
- Grosheva M, "Significance of electromyography to predict and evaluate facial function outcome after acute peripheral facial palsy", Eur Arch Otorhinolaryngol, 264(12), pp.1491~1495 (2007)
- Anon JB, "Monitoring the facial nerve during parotidectomy", Arch Otolaryngol Head Neck Surg, 117(12), pp.1420~ (1991)
- Empis de Vendin O, "Recurrent laryngeal nerve monitoring and rocuronium : a selective sugammadex reversal protocol", World J Surg, 41(9), pp.2298~2303 (2017)
- Wu CW, "Loss of signal in recurrent nerve neuromonitoring : causes and management", Gland Surg, 4(1), pp.19~26 (2015)
