Purpose: To investigate the correlation between peripheral anterior synechia (PAS) and the quantitative anterior chamber angle parameters measured by ultrasound microscopy (UBM) in angle-closure glaucoma suspect (ACGS) eyes. Methods: Eyes were defined ACGS as having occludable angles and intraocular pressure less than 21 mm Hg without glaucomatous optic nerve head. The gonioscopic criteria for ACGS were the trabecular meshwork invisible in 3 or more quadrants of the entire angle and the angular width less than 20 degrees by Shaffer classification. Twenty-seven eyes of 20 patients underwent anterior chamber angle and ciliary body imaging with UBM. Angle opening distance (AOD500), angle recess area (ARA), trabecular-ciliary process distance (TCPD) and trabecular-iris angle (TIA) were measured from the UBM images at each quadrant. Results: The AOD500, ARA, and TIA were not significantly different between the eyes with PAS (9 eyes) and without PAS (18 eyes) at each quadrant. However, the TCPD was significantly shorter in the superior quadrant when compared with the eyes without PAS (mean: 405.3±70.9 µm vs 536.4±140.5 µm) (p<0.05). Conclusions: The results suggest that the shorter distance from trabecular meshwork to ciliary body or the anterior placement of ciliary process may play a role in the development of PAS in ACGS eyes.
Abstract
Purpose: To investigate the correlation between peripheral anterior synechia (PAS) and the quantitative anterior chamber angle parameters measured by ultrasound microscopy (UBM) in angle-closure glaucoma suspect (ACGS) eyes. Methods: Eyes were defined ACGS as having occludable angles and intraocular pressure less than 21 mm Hg without glaucomatous optic nerve head. The gonioscopic criteria for ACGS were the trabecular meshwork invisible in 3 or more quadrants of the entire angle and the angular width less than 20 degrees by Shaffer classification. Twenty-seven eyes of 20 patients underwent anterior chamber angle and ciliary body imaging with UBM. Angle opening distance (AOD500), angle recess area (ARA), trabecular-ciliary process distance (TCPD) and trabecular-iris angle (TIA) were measured from the UBM images at each quadrant. Results: The AOD500, ARA, and TIA were not significantly different between the eyes with PAS (9 eyes) and without PAS (18 eyes) at each quadrant. However, the TCPD was significantly shorter in the superior quadrant when compared with the eyes without PAS (mean: 405.3±70.9 µm vs 536.4±140.5 µm) (p<0.05). Conclusions: The results suggest that the shorter distance from trabecular meshwork to ciliary body or the anterior placement of ciliary process may play a role in the development of PAS in ACGS eyes.
참고문헌 (25)
- Inoue T, "Kitazawa Y. Distribution and morphology of peripheral anterior synechiae in primary angle-closure glaucoma. J Glaucoma 1993", pp.171~6
- "Kronfeld PC. Delayed restoration of the anterior chamber. Am J Ophthalmol 1954", pp.453~65
- Choi JS, "Relationship between the extent of peripheral anterior synechiae and the severity of visual field defects in primary angle-closure glaucoma", 18(2), pp.100~105 (2004)
- Aung T, "Configuration of the drainage angle, intraocular pressure, and optic disc cupping in subjects with chronic angle-closure glaucoma", 112(1), pp.28~32 (2005)
- West RH. Creeping angle-closure glaucoma, "the influence of iridotomy and iridectomy. Aust N Z J Ophthalmol 1992", pp.23~8
- Yamamoto T, "Shirato S. Treatment of primary angle-closure glaucoma by argon laser iridotomy", pp.1~12
- Choi JS, "Progression of peripheral anterior synechiae after laser iridotomy", 140, pp.1125~1127 (2005)
- Kim YY, "Clarifying the nomenclature for primary angle-closure glaucoma", 42, pp.125~136 (1997)
- Ritch R, "Foster FS. Ultrasound biomicroscopy in plateau iris syndrome. Am J Ophthalmol 1992", pp.390~5, Pavlin CJ
- Pavlin CJ, "Ultrasound Biomicroscopy of the Eye", pp.140~154 (1995), New York: Springer-Verlag
- Eng P, "et al. Ultrasound biomicroscopy of anterior segment structures in normal and glaucomatous eyes. Am J Ophthalmol 1992", pp.381~9, Pavlin CJ
- "Gorin G. Shortening of the angle of the anterior chamber in angle closure glaucoma. Am J Ophthalmol 1960", pp.141~6
- "Lowe RF. Clinical types of primary angle closure glaucoma. Aust NZ J Ophthalmol 1988", pp.245~50
- "Lowe RF. Aetiology of the anatomical basis for primary angle closure glaucoma. Br J Ophthalmol 1970", pp.161~9
- Sakuma T, "Appositional angle closure in eyes with narrow angles: an ultrasound biomicroscopic study", 6, pp.165~169 (1997)
- "Phillips CI. Sectorial distribution of goniosynechiae. Br J Ophthalmol 1956", pp.129~35
- Phillips CI. Closed-angle glaucoma, "significance of sectorial variations in angle depth. Br J Ophthalmol 1956", pp.136~43
- Leighton DA, "Phillips CI. Early angle-closure glaucoma. Distribution of iridotrabecular contact and response to pilocarpine. Arch Ophthalmol 1973", pp.369~72
- "Barkan O. Etiology of narrow-angle glaucoma report of a case of glaucoma secondary to anterior displacement of the lens iris diaphragm. Am J Ophthalmol 1953", pp.901~6
- Barkan O. Narrow-angle glaucoma, "effect of miosis on the narrow-angle mechanism and intraocular pressure. Am J Ophthalmol 1953", pp.1387~8
- Kunimatsu S, "Prevalence of appositional angle closure determined by ultrasonic biomicroscopy in eyes with shallow anterior chambers", 112, pp.407~412 (2005)
- Salmon JF, "Predisposing factors for chronic angle-closure glaucoma", 18, pp.121~132 (1998)
- Yeung BY, "Prevalence and mechanism of appositional angle closure in acute primary angle closure after iridotomy", 33, pp.478~482 (2005)
- "Ritch R. Plateau iris is caused by abnormally positioned ciliary processes. J Glaucoma 1992", pp.23~6
- Leighton DA, "Tsukahara S. Profile of presenting states of eyes in angle-closure glaucoma. Br J Ophthalmol 1970", pp.577~84